Release Notes for MOBOTIX Camera Software
Document Information
Publisher:
|
MOBOTIX AG
|
Author:
|
Bernd Wilhelm
Thilo Schüller
|
Date:
|
2017-08-17
|
Document:
|
release-notes_en.html
|
Confidentiality:
|
public
|
Contents
These Release Notes contain a technical description of the most
important changes in the software for the MOBOTIX network cameras.
Software Releases—Overview:
Notes:
- Please download the stable customer releases of the software from www.mobotix.com
in the Support > Software Downloads section.
- Please note that some of the described features in the dialogs will
only be visible if the More button at the bottom of a
dialog has been pressed.
- Please send an email to intl-support@mobotix.com
for feedback.
top
Software Release MX-V5.0.0.133 − for Mx6 Camera Models D16, M16, S16,
V16, D26, M26, Q26, S26, c26, i26, p26, v26 − With Thermal Sensors as well
as 6MP and 5MP Image Sensors
Creation Date: 2017-07-21
Publishing Date: 2017-08-08
Important Notes
- Fixed gSOAP security issue in OVIF
integration
This release fixes the gSOAP security issue "Devil's Ivy", which was
created due to a vulnerable part of the ONVIF Toolkit. It is therefore
strongly recommended to update cameras with
older software versions to this release (see corresponding entry in
the Bugfixes section).
- Identical user interface
The software of the cameras with the new hardware platform is mostly
identical to the software of the predecessor models D/M/S/V15,
D/M/Q25/S15M and i/c/p/v25 - the so-called P3 models.
- Support of existing configurations
You can load existing camera configuration files of the corresponding
P3 camera models without any problems. This is important when
exchanging a camera or when integrating new cameras into existing
systems.
Enhancements and Improvements
Support of FTPS (TLSv1, TLSv1.1 and TLSv1.2)
This software release supports file transfers of the camera using FTPS
(FTP via Transport Layer Security). The supported TLS versions are
TLSv1, TLSv1.1 and TLSv1.2.
Other Improvements
- Improvement to Intrusion Detection
When attempting to connect an IP address that is blocked by
intrusion detection, the error message "404 not found" can now be
returned by the camera instead of the standard error message "403
forbidden". For that purpose the following entry must be inserted in the
camera configuration file:
SECTION httpd
ids_http_403_to_404=1
ENDSECTION httpd
- Update of the OpenVPN-Client to version 2.4.3.
This version provides, among other things, improved protection
against DoS and memory overflow attacks.
Bugfixes
- Fixed gSOAP security issue in OVIF integration
This release fixes the gSOAP security issue "Devil's Ivy", which was
created due to a vulnerable part of the ONVIF Toolkit.
However, this vulnerability could only be exploited in the affected
software releases, if the ONVIF integration had been activated. If
only the MxPEG video streaming codec developed by MOBOTIX was being
used, the vulnerability could not be exploited.
- Profile for Network Messages and Full Image Recording
When using profiles for network notifications (IP-Notify) with event
images in combination with Full Image Recording, the IP Notify message
was not sent if the triggering event of such a profile did not
simultaneously trigger recording.
- Image Logo Upload
Automated uploading of logos via web server URLs did not work
properly in some cases.
- Thermal TR cameras with temperature values above 2000° C
A Thermal TR camera could, in rare cases, display a temperature of
more than 2000 ° C.
- Integration Protocols dialog and IE 11
The Admin Menu > Cameras Administration >
Integration Protocols dialog did not work properly when using
Internet Explorer 11. The changes made in the dialog were not
stored properly in the camera.
Known Limitations
- SIP video
This release does not support SIP video. This feature will be available
again in a later release.
- Shock Sensor
This version does not yet support the integrated shock sensor to trigger Shock Sensor events.
top
Software Release MX-V5.0.0.130 − for Mx6 Camera Models D16, M16, S16,
V16, D26, M26, Q26, S26, c26, i26, p26, v26 − With Thermal Sensors as well
as 6MP and 5MP Image Sensors
Creation Date: 2017-06-21
Publishing Date: 2017-07-14
Important Notes
- Identical user interface
The software of the cameras with the new hardware platform is mostly
identical to the software of the predecessor models D/M/S/V15,
D/M/Q25/S15M and i/c/p/v25 - the so-called P3 models.
- Support of existing configurations
You can load existing camera configuration files of the corresponding
P3 camera models without any problems. This is important when
exchanging a camera or when integrating new cameras into existing
systems.
Enhancements and Improvements
Support of Mx6 Indoor Camera Models
This software release also supports the new Mx6 indoor camera models i26,
c26, p26 and v26. As a consequence, the new features of the Mx6 camera
line are also supported on these models (noticeably higher frame rates,
H.264 video streaming, ONVIF, etc. In addition, the design and the
handling of the i26, c26, p26 and v26 cameras does not differ from their
predecessor models of the P3 camera line.
Factory Default Settings changed
The following factory default settings have been changed in this version:
- Image size = MEGA and Image Quality = Normal
The camera now delivers 25 fps immediately after first start
because of this change.
- Genetec and ONVIF Support activated per default
The integration of cameras in Genetec and ONVIF video management systems
is easier now because Genetec and ONVIF
are now activated per default in the Admin
Menu > Camera Administration > Integration Protocols dialog.
Note: If you do not want the ONVIF services to be activated
automatically you have to deactivate them explicitely in the dialog
mentioned above.
Event Stream Group Right for Integrating Cameras into
MxManagementCenter
To integrate a MOBOTIX camera into MxManagementCenter (MxMC), you had to
use the access credentials of a user with admin rights on the camera.
This software release provides a better solution: In the Admin
Menu > Security > Group Access Control Lists, you
can now add a new group with the new Event Stream right. If you
are using the credentials of such a user to integrate the camera into
MxMC, you can use all features of MxMC (except updating the camera
software). In addition, the user cannot make any configuration changes in
the browser-based user interface of the camera.
Separating the rights in such a manner has significantly increased the
system security, especially where larger installations are concerned.
Enhanced Security Thanks to Special Characters in Passwords
Firmware release MX-V5.0.0.130
(just like MX-V5.0.0.127
)
allows using special characters to create more complex passwords (Admin
Menu > Security > Users and Passwords). This again
increases the protection against unwanted camera access. To prevent
problems when logging in from different browsers, all printable special
characters from the US ASCII character set are allowed:
! " # $ % & ' ( ) * +, −. /:; < = >? @ [ \ ] ^ _ `{ | } ~.
ONVIF Description
The online help for the ONVIF integration has been extended.
Bugfixes
- M16: Day/night operation
When using an M16 in Day/Night mode, the Black&White (Night) image
sensor sometimes showed image errors.
- Warning note for network settings
After changing and storing the network settings in the Admin
Menu > Network Configuration > Ethernet Interface
dialog, the Administration dialog showed a faulty warning in the
Network Configuration section.
- Storage on external file server after changing the language
After setting French or Italian as language in the browser-based user
interface, the Admin Menu > Storage > Storage on
External File Server / Flash Device dialog showed some wrong
contents.
Known Limitations
- IP Notify profiles and full image recording
When using IP notify (network message) profiles with event images in
combination with full image recording, errors may occur if the event
that triggered the sending of the message not also triggers a recording.
- Logo upload
The automated loading of logos from web server URLs does not always work
reliably.
- Thermal TR cameras show temperature values above 2000 °C.
On rare occasions, Thermal-TR cameras can show temperatures above
2000 °C.
- Integration Protocols dialog and IE 11
The Admin Menu > Cameras Administration >
Integration Protocols dialog does not work properly when using
Internet Explorer 11. The changes made in the dialog will not be
stored properly in the camera.
- SIP video
This release does not support SIP video. This feature will be available
again in a later release.
- Shock Sensor
This version does not yet support the integrated shock sensor to trigger Shock Sensor events.
top
Software Release MX-V5.0.0.127 − for Mx6 Camera Models D16, M16, S16,
V16, D26, M26, Q26, S26 − with Thermal Sensors as well as 6MP and 5MP
Image Sensors
Creation Date: 2017-04-27
Publishing Date: 2017-05-05
Important Notes
- First published software for Mx6 models with higher performance
This is the first published software release for the new Mx6 camera
models with dual-core processor. The camera benefits from the
performance boost especially where extra computational power for image
analysis is required, such as for MxAnalytics. Noticeably higher frame
rates in MxManagementCenter or in the browser are yet another plus.
- Identical user interface
The software of the cameras with the new hardware platform is mostly
identical to the software of the predecessor models D/M/S/V15 and
D/M/Q25/S15M - the so-called P3 models.
- Support of existing configurations
You can load existing camera configuration files of the corresponding
P3 camera models without any problems. This is important when
exchanging a camera or when integrating new cameras into existing
systems.
The following list describes the new features, enhancements and
improvements as compared to the P3 models (software releases V4.x
).
Enhancements and Improvements
Higher Frame Rates
As mentioned above, the Mx6 models display noticeably higher frame rates
with less variation as in the P3 camera models. This is mainly due to the
higher computational power of the dual-core processor. The frame rate can
reach 42 fps when using HD image size (1280x720), the MxPEG video
codec and Normal image quality:
Note: Select the Fast image program from the Quick
Controls to automatically apply all settings that result in the highest
possible frame rate.
RTP Streaming, H.264 and Genetec Integration
To integrate these camera models into other video management systems, you
can use RTP streaming, H.264 and a special Genetec integration interface.
Open the Admin Menu > Camera Administration >
Integration Protocols dialog and activate the RTP Server
and/or Genetec options to use these features.
Notes:
- The maximum image size of an H.264 RTP stream is limited to QXGA
(2048x1536).
- As a matter of fact, the Mx6 cameras can be integrated into the
Genetec Security Center, even though they have not been certified
accordingly.
ONVIF Integration
This is the first software release to support the ONVIF standard; it
complies with many basic features of this global and open communication
standard. Currently, the following ONVIF features or codecs and protocols
are supported: Discovery Service, Digest Authentication, Scope Management,
Profiles with Reset via Web UI, H.264, M-JPEG, RTP, TCP, HTTP.
Open the Admin Menu > Camera Administration >
Integration Protocols dialog and activate the ONVIF option
to activate the integrated ONVIF support. If you activate the ONVIF
Discovery Service in this dialog, you can also define ONVIF
Scopes and show or delete the ONVIF Profiles created by an
ONVIF video management system.
Bugfixes
The bugfixes described in the following refer to the software releases
prior to release V5.0.0.127
that had been delivered with the
first Mx6 camera models.
- Recording on SMB/CIFS file server
When using an SMB/CIFS file server as primary recording target (with MX
folder/file structure) or as MxFFS archive, the camera sometimes could
not connect to the file server.
- Several RTP H.264 streams
When requesting more than one RTP H.264 stream, the additional streams
sometimes displayed image errors.
- RTP server and storage on file server as primary target
When recording on a file server as primary storage target (MX
folder/file structure) and activating the RTP server, a camera reboot
sometimes deleted the recorded video data.
Known Limitations
- SIP video
This release does not support SIP video. This feature will be available
again in a later release.
- Shock Sensor
This version does not yet support the integrated shock sensor to trigger Shock Sensor events.
Copyright © 1999 – 2017, MOBOTIX
AG, Germany, sales@mobotix.com