Release Notes for MOBOTIX HUB DriverInstaller
  Document Information
  
    
      
        | Publisher: | MOBOTIX AG | 
      
        | Author: | Jörg Steuerwald | 
      
        | Date: | 2022-05-12 | 
      
        | Document: | MOBOTIX_DriverInstaller121a_en_v2.html | 
      
        | Confidentiality: | public | 
    
  
  
  Contents
  The following document provides information about the specific features of each version of MOBOTXI HUB.
  Software Releases—Overview
  
    
      
        | Release Version | Release Date | 
    
    
      
        | 121a 
 | 2022-05-12 | 
    
  
  
   
   
  
  
    top
  Version 121a of MOBOTIX HUB DriverInstaller
  Published on: 2022-05-12
  Device Compatibility Overview
  This release note lists the changes in Device Pack 12.1a that are supported all MOBOTIX HUB Version from L1 to L5.
  Device Pack Updates
  New firmware support for devices for the following partners:
  
    - Axis
- IDIS
- Pelco
- Vivotek
- Zenitel
Additional support for specific features for the following partners and drivers:
  
    - Axis
    
 Added support for new “Absolute Time” setting in General section
    - Digitale Barrieren
    
 Updated SDK version to 8.1.3
    - Hanwha
    
 Added support for Dynamic Events on new APP based API cameras
    - iPRO/Panasonic
    
 Enable additional channels for fisheye cameras when using Quad stream mode
ONVIF updates:
  New “Home position preset” setting for choosing a custom PTZ preset as home position
  New device support for:
  
    - 3XLOGIC
    
 VX-5M4-MB-IW, VX-5M20-B-RIAW, VX-5M-B-RIAW, VX-5M28-MD-IW, VX-5M4-MD-IW, VX-5M28-MD-IAW, VX-5M4-MD-IAW,
    VX-5M-OD-RIAW, VX-6M-360-IA-02, VX-6M-360-IAW, VX-2M-OD-RIAW, VX-2M-ID-RIAW
    - Axis
    
 M4216-V, M4216-LV, P3265-LVE, P3265-LV, P3265-V, P3267-LV, P3267-LVE, P3268-LV, P3268-LVE, P7316,
    Q3538-LVE, Q3536-LVE, ExCam XF P1377
    - Comelit Group S.p.a
    
 IPBCAMA04ZA, IPBCAMA04ZB, IPBCAMA04Z01A, IPBCAMA04FA, IPTCAMA04ZA, IPTCAMA04FA, IPKCAMA04ZA, IPLPRA02ZA
    - Dahua
    
 DH-TPC-BF1241-T, DH-TPC-DF1241-T, DH-TPC-BF1241-WIFI, DH-TPC-BF5421-T, DH-TPC-BF5421,
    DH-TPC-PT8421A-T, DH-TPC-PT8621A-T, DH-PTZ83440-HNF-PA, DH-IPC-HUM8441-E1, DH-IPC-
    HUM8441-E1-L1, DH-IPC-HUM8441-E1-L3, DH-IPC-HUM8441-E1-L4, DH-IPC-HUM8441-E1-L5, DH-
    IPC-HUM8241-E1, DH-IPC-HUM8241-E1-L1, DH-IPC-HUM8241-E1-L3, DH-IPC-HUM8241-E1-L4, DH-
    IPC-HUM8241-E1-L5, DH-IPC-HUM8241-E2, DH-IPC-HUM8441-E2
    - FLIR
    
 FH-324 R, FH-669 R, FH-612 ID
    - Hanwha Techwin
    
 XNZ-6320A, XNZ-L6320A, TNV-7011RC, TNV-8011C
    - HikVision
    
 DS-7324HUHI-K4, DS-7332HUHI-K4, DS-2TD4137-X/ WY, DS-2TD4137T-X/W, DS-2TD4167-X/ WY, DS-2TD4167T-X/W,
    DS-2TD6237-X4L/W, DS-2TD6237T-XH4L/W, DS-2TD6267-X4L/W, DS-2TD6267-X4L/WY, DS-2TD6267T-XH4L/W,
    DS-2TD8167-190ZE2F/WY, DS-2TD8167-230ZG2F/W, DS-2TD8167-230ZG2F/WY, DS-2DF8225IX-AEL(T5), DS-2DF8225IX-AELW(T5),
    DS-2DF8242IX-AEL(T5), DS-2DF8242IX-AELW(T5), DS-2DF8242IX-AELY(T5), DS-2DF8242IX-AELWY(T5), DS-2DF8242I5X-AELW(T5),
    DS-2DF8425IX-AEL(T5), DS-2DF8425IX-AELW(T5), DS-2DF8442IXS-AEL(T5), DS-2DF8442IXS-AELW(T5),
    DS-2DF8C442IXS-AEL(T5), DS-2DF8C442IXS-AELW(T5), DS-2DF8C825IXS-AEL(T5), DS-2DF8C825IXS-AELW(T5),
    DS-2DF8C842IXS-AEL(T5), DS-2DF8C842IXS-AELW(T5), DS-2DF8C448I5XS-AELW(T5), DS-2DF8C848I5XS-AELW(T5),
    DS-2DF8C260I5XS-AELW(T5), DS-2DF8A442IXS-AF/SP(T5), DS-2DF8A442INXS-AEL(T5), DS-2DF8A442IXS-AEL(T5),
    DS-2DF8A442IXS-AELY(T5), DS-2DF8A842IXS-AEL(T5), DS-2DF6A225X-AEL(T5), DS-2DF6A436X-AEL(T5), DS-2DF6A436X-AELY(T5),
    DS-2DF6A836X-AEL(T5), DS-2DF8C442I5XS-AELW(T5), DS-2DT6425X-AELY(T5), DS-2DT6232X-AELY(T5), DS-2DF8442IXS-AELY,
    DS-2DF8242IX-AEL, DS-2CD6924G0-IHS, DS-2DE7A232IW-AEB
    - Interlogix
    
 TVGP-M01-0201-BUL-G, TVGP-M01-0401-BUL-G, TVGP-M01-0801-BUL-G, TVGP-M01-0202-BUL-G,
    TVGP-M01-0402-BUL-G, TVGP-M01-0802-BUL-G, TVGP-M01-0201-DOM-G, TVGP-M01-0201-DOM-W,
    TVGP-M01-0401-DOM-G, TVGP-M01-0401-DOM-W, TVGP-M01-0801-DOM-G, TVGP-M01-0801-DOM-W,
    TVGP-M01-0202-DOM-G, TVGP-M01-0202-DOM-W, TVGP-M01-0402-DOM-G, TVGP-M01- 0402-DOM-W, TVGP-M01-0802-DOM-G,
    TVGP-M01-0802-DOM-W, TVGP-M01-0201-TUR-G, TVGP-M01-0201-TUR-W, TVGP-M01-0201-TUR-B, TVGP-M01-0401-TUR-G,
    TVGP-M01-0401-TUR-W, TVGP-M01-0401-TUR-B, TVGP-M01-0801-TUR-G, TVGP-M01-0202-TUR-G, TVGP-M01-0402-TUR-G,
    TVGP-M01-0402-TUR-W, TVGP-M01-0802-TUR-G, TVGP-M01-0201-WED-G, TVGP-M01-0401-WED-G, TVGP-M01-0401-WED-W,
    TVGP-M01-0401-WED-B, TVTH-S01-0001-BUL-G, TVTH-S01-0002-BUL-G, TVTH-S01-0003-BUL-G, TVTH-S01-0001-TUR-G,
    TVTH-S01-0002-TUR-G, TVTH-S01-0003-TUR-G, TVTH-S01-0004-BUL-G
    - iPRO/Panasonic
    
 WV-S2536LTNJ, WV-S2536LNJ, WV-S2136LJ, WV-S1536LTNJ, WV-S1536LNJ, WV-S1136J, WV-S2135,
    WV-S1135V, WV-S2116L, WV-S2116LD, WV-S1516LN, WV-S1516LDN, WV-S1116, WV-S1116D, WV-S2115,
    WV-S1515L, WV-S1115V, WV-S4576LJ, WV-S4176J, WV-S4556LJ, WV-S4156J
    - Johnson Controls
    
 IES02-D10-OI04, IES02-D12-OI04, IES02-B10-BI04, IES02-B12-BI04
    - Milesight Technologyt Co., Ltd
    
 MS-C2962-TFPA, MS-C2862-TFIPA, MS-C2862-TFPA, MS-C2962-TFIPA, MS-C8262-FPA, MS-C8262-FIPA,
    MS-C2841-X36TPA, MS-C2941-X23TPA, MS-C2941-X30TPA, MS-C2941-X42TPA, MS-C8241-X36PA, MS-C2872-TFPA,
    MS-C2872-TFIPA, MS-C2962-TEPA, MS-C2972-TFPA, MS-C2972-TFIPA, MS-C8272-FPA, MS-C8272-FIPA, MS-C9674-PA,
    MS-C2871-X20TPA, MS-C2971-X12TPA, MS-C2971-X23TPA, MS-C5365-PA, MS-C5376-PA, MS-C8165-PA, MS-C8176-PA
    - Oncam Grandeye
    
 C-12-Outdoor-Camera, C-12-Indoor-Camera, C-08-Outdoor, C-08-Indoor
    - Pelco
    
 IBD332-1, IBD532-1, IDL0-PU2, IBD332-1SS, IBD532-1SS
    - QSNET Visual Technologies
    
 RBU8164-PC, RDO8173-PC, RDO5375-fpc, RPZ5341-X30PC, RBU5364-FPC
    - Uniview
    
 IPC2128SB-ADF40KM-I0-NB, IPC2128SB-ADF28KM-I0-NB, IPC2128SB-ADF40KM-I0, IPC2128SE-
    ADF28KM-WL-I0, IPC2128SE-ADF40KM-WL-I0, IPC2128SE-ADF40KM-WL-I0-NB, IPC2128SE-
    ADF28KM-WL-I0-NB, IPC3618SE-ADF40KM-WL-I0, IPC3618SE-ADF28KM-WL-I0, IPC3618SE-
    ADF40KM-WL-I0-NB, IPC3618SE-ADF28KM-WL-I0-NB, IPC2122LB-AF28WK-G(-NB), IPC2122LB-
    AF40WK-G(-NB), IPC322LB-AF28WK-G(-NB)
    - Vivotek
    
 MD9584-H, SD9368-EHL
    - Zenitel
    
 ELSII-10HM, ELSII-10LHM, ELSII-10PM, ELSII-10WM, ELSIR-10CM, TKIS-2
Fixed Issues:
  
    - Fixed issue with Panasonic camera event alarms not received when multiple cameras are connected to MOBOTIX HUB.
- Fixed issue with “Express” hardware discovery not detecting some Panasonic models, due to
      model name mismatch. Affected models (WV-X1551LN / WV-X2251L / WV-X2551LN / WV-
      X1571LN / WV-X1571LNJ / WV-X2271L / WV-X2571LNJ / WV-X2571LN). 
- LFixed slow edge storge retrieval for Hikvision DS-2CD2525FWD-IS with firmware V5.6.6 build
      220117. Scale for video storage retrieval is increased to 100 in the driver.
- Fixed issue with Central click zooming to initial position for Dahua DH-SD6AL830V-HNI.
- Fixed issue with video stream lost on Digital Barriers. 
ADDITIONAL REMARKS
  Replace Hardware Remarks:
  Be aware that after using Replace Hardware and changing the license, the license should always be
  checked to verify that it is activated.
  4K Remarks:
  Due to the nature of 4K and the high resolution at high frame rates, this will increase the demand for high
  performing network, CPU, graphic adaptors, and monitors. Unless all components in the hardware
  infrastructure is prepared for a high load, there might be limitations seen as latency, stutter etc.
  4K - Recommended MOBOTIX HUB version 2021 or newer, supporting HW accelerated decoding using the GPU
  ONVIF upgrade from DP 6.2 or earlier remarks:
  After upgrade, some ONVIF devices might not work. The new version of ONVIF now only shows features
  that a responding correctly through the ONVIF interface. Since MOBOTIX HUB L5 does not allow things
  like e.g. Audio, Input or similar to be removed, the ONVIF device will not be upgraded properly and hence
  not work. A work-around is to do replace hardware.
  
After upgrade Video Stream 1 and 2 might not correctly reflect the actual settings on those profiles. This
  is due to the ONVIF driver only used to have two video streams, where you selected a profile, where it now
  will have a video stream for each profile. MOBOTIX HUB L5 “copies” the settings for each video stream
  
when the driver is upgraded, so if Video Stream 1 or 2 did not have the correct profile that is now mapped
  to the stream it will show the same settings as before the upgrade even though the mapped profile might
  actually have other settings. The streams should work with the new settings unless some of these are not
  supported on the profile.
  
Some settings might be missing because the driver now only looks for the different type of settings in the
  places, they should be according to standard.
  
Some features might not work any longer because the driver now only looks for the features and
  corresponding settings in the places and in the format, they should have according to the standard.
  Profile names might get changed after the upgrade because we now use the names given by the device
  for the profiles. These will not always correspond to what was previously used.
  MOBOTIX remarks:
  For the Mobotix Q24 / Q25/ Q26: With JPEG streaming and use of Audio, there is a tradeoff between
  network bandwidth and audio quality. In order to lower the bandwidth, the user should tune the FPS
  of MxPEG codec settings in a way that audio quality still have a good quality.
  Axis Remarks:
  The Axis M, P and Q drivers (except P8221) have been replaced with four new dynamic drivers that also
  supports the new Axis Events handling. This means that all new devices added to a system will
  automatically be detected on one of the new drivers.
  
Note: If your devices are using firmware 5.20 or lower then Events and I/O will not work with the new
  drivers. You should either upgrade to a newer firmware or manually select the driver to add the device.
  Be aware if you add the device manually and later upgrade the firmware you will need to do a Replace
  Hardware to change to the new driver.
  
Note: Before Replacing Hardware to only change the driver and not the hardware please contact
  Support on how to do this correctly.
  
AVHS: Due to a limitation in the firmware only 9 socket connections can be open on an AVHS device at
  any time. JPEG video streams, Audio In streams, Audio Out and Output streams use 1 socket connection
  each. H.264 video streams, Events, Inputs and Edge Storage use 2 connections each. This also means that
  when upgrading from a previous Device Pack to 7.3 all Channels should be disabled before the upgrade.
  
AVHS: Audio Out does not work properly with firmware before 5.50 when running the 2013 or older
  versions. To get Audio Out to work in the 2013 or older versions with a firmware before 5.50 you need to
  either enable anonymous login or disable all authentication on the device. Audio Out will work with
  firmwares before 5.50 on the new 2014 versions.
  Axis S3008 Recorder integration
  (KB 000035801; KB 000034500)
  
Axis S3008 Recorder is used as an external storage for camera devices added to MOBOTIX HUB VMS.
  It is not added as a separate hardware device.
  
The cameras should be connected to Axis Recorder and properly set in Management client to retrieve the recordings.
  
Setup steps:
  
  - Connect the Axis S3008 Recorder to your device network.
- Define username and password for the Recorder.
- Add the camera devices in MOBOTIX HUB.
- For each device make the next settings in Management client:
  
 - Select the preferred stream used for recording from the drop-down menu in
        Settings tab > Stream number section > "Recorder stream index" field
The following settings are dedicated to adjust the S3008 Recorder parameters:
  
    - Recorder audio enabled – Enable audio recording. Audio channels map one to one with that of video
      
        - Yes – Audio recording is enabled
- No – Audio recording is disabled (default)
 
- Recorder mode – Select desired mode/action for recording
      
         - Disabled – The recording for this channel is disabled (default)
- Continuous – The external recorder will record continuously
- Motion - The external recorder will record on motion
 
- Recorder post-trigger time (seconds) - Specify the number of seconds to include from the
        time immediately after a recording is stopped.
- Recorder pre-trigger time (seconds)- Specify the number of seconds to include from
        the time immediately before a recording is started once the Motion/event is activated.
- Recorder retention time (hours) - The maximum number of hours that a recording will be
        saved. A zero means indefinite.
- Recorder stream index - preferred stream settings (Video stream 1 - Video stream 8) used
        for recording. Some constraints are:
      
          - In case of MJPEG codec, the recording stream will use H.264 instead
- When the ZipStream GOP mode is set to Dynamic, the recording will still use Fixed
- The maximum keyframe interval is limited to 100
          
 
 - In Settings tab > External Recorder
 Enter the Axis Recorder IP address and credentials (as defined in step2).
 
There are the following known limitations:
    - The camera devices can use only the default ports (80 or 443). 
- Error handling is still not fully implemented. 
- If a device connected to Axis Recorder is removed from Management Client, the recordings
         from this device on Axis Recorder are not removed.
Bosch remarks:
  For Bosch devices with FW 6.60 and above, adding might fail, if you use Auto Discovery method and have
  more than 3 unsuccessful tries with incorrect credentials. To avoid that, we recommend‚ manually add
  these Bosch devices with correct credentials.
  Hikvision remarks:
  Due to the new security policy introduced by Hikvision with the 5.3.x baseline firmware, adding Hikvision
  cameras may cause temporary lockout of devices, even if the correct username and password have been
  predefined. This can be avoided by disabling the ‘Enable Illegal Login Lock’ option on the camera’s
  webpage, if it is available in the firmware.
  
  
Firmware versions supporting the ‘Enable Illegal Login Lock’:
  
v5.3.8 build 150722
  
v5.3.0 build 150513
  
v5.3.8 build 151224
  
v5.3.10, build 150917
  
  
Firmware versions without the ‘Enable Illegal Login Lock’:
  
v5.3.8 build 150707
  
v5.3.9 build 150910
  
  
Recommended installation steps:
  
For devices that have the ability to control the Illegal Login Lock:
  
  
It is recommended to disable the Illegal Login Lock from camera’s web page prior adding the device to MOBOTIX HUB software.
  Enabling it afterwards will not affect the functionality of this camera.
  
If disabling this feature is not an option, please mind the following:
  
    - Avoid using express scan. If this is not an option, please specify the username and password on top
of the credentials’ list.
- When using IP range don’t define more than 1 password and username.
- If you need to add a lot of cameras with different credentials it is recommended using CSV file method.
- Use manual add method (auto discovery).
    For devices without Illegal Login Lock control in their webpage:
- Avoid using express scan. If this is not an option, please specify the username and password on top
    of the credentials’ list.
- When using IP range don’t define more than 1 password and username.
- If you need to add a lot of cameras with different credentials it is recommended using CSV file method.
- Use manual add method (auto discovery). 
Using firmware 5.5.0 and later versions
  
With firmware 5.5.0 Onvif will no longer be enabled by default.
  
To enabled it, you need to use the Hikvision’s tool which is found on their webpage or do it directly on the
  cameras homepage.
  
Multi stream devices: Some Hikvision cameras has support for up to 10 streams. If stream 6 to 10 needs
  to be used it should be set up on the cameras webpage before the device is added to Milestone.
  
Video will be lost if stream 6 to 10 is selected in Milestone and not set up on the cameras webpage.
  Panasonic remarks:
  Be aware that changing a stream setting on a device using i-Pro/Panasonic driver will apply the change on
  all its channels, due to device specifics.
  Stretch Remarks:
  To accommodate requests that the Stretch cards can run in a machine that has no Network card, the
  Stretch cards will from Device Pack 7.1 use a new scheme to retrieve a serial number. This means that
  when updating from a previous device pack, you need to run a Replace Hardware and get a new license
  for the Stretch cards to work.
  
Stretch driver is last contained in Device Pack 11.2. It is included in Legacy device Pack 2.0
  
Der Stretch-Treiber ist zuletzt in Device Pack 11.2 enthalten. Er ist im Legacy Device Pack 2.0 enthalten.
   
   
  