    Release Notes for MOBOTIX Camera Software
    Document Information
    
      
        
          | Publisher: | MOBOTIX
              AG | 
        
          | Author: | Bernd Wilhelm | 
        
          | Date: | 2023-04-28 | 
        
          | Document: | V7.3.2.76_release-notes_en_v1.html | 
        
          | Confidentiality: | public | 
      
    
    
    Contents
    These Release Notes contain a technical description of the most
      important changes in the software for the MOBOTIX network camera line M7.
    Software Releases—Overview
    
    Notes:
    
      - Please download the stable customer releases of the software from www.mobotix.com in the Services 
          > Download Center > Software Downloads section.
- Please note that some of the described features in the dialogs will
        only be visible if the More button at the
        bottom of a dialog has been pressed.
- Please send an email to support@mobotix.com
        for feedback.
 
     
     
     
     
     
     
     
    
    top
     
    Software Release MX-V7.3.2.76 − for M7 Camera Models M73, S74, Q71, D71,
      c71, p71, p71TA, v71
    Creation Date: 2023-04-26
    Publishing Date: 2023-05-02
    
      Important notes on installation
      
        -  This version supports
            all MOBOTIX 7 camera models. They are all updated with the same file
            MX_system_7_3276.mpl
              from the Services > Download Center > All
              software downloads > cameras > MX system release 7.3.2.76 section
            of the MOBOTIX website (https://www.mobotix.com). 
- 
          If you are using Certified Apps in the camera,
            you must update them using the MX_preinstalled_apps_2023-04-26.app
            package from the Services > Download Center
              > All Software Downloads > Certified Apps section
            of the MOBOTIX website (https://www.mobotix.com). This
            package also includes the App MOBOTIX Analytics with
              AI/deep learning-based object recognition. 
 
    
    Enhancements and improvements
    
    Integration of MQTT protocol
    This version supports the widely used, efficient and bandwidth-optimized
      MQTT network protocol for exchanging messages between IoT devices. The
      camera can use the so-called MQTT broker to publish its own messages, for
      example when certain events occur, as well as subscribe to messages from
      other MQTT devices and react accordingly when they are received. For this
      purpose, the following new dialogs and functions have been implemented:
    
      - The new Admin Menu > Network Configuration > MQTT Configuration
        dialog is used to activate MQTT, configure the MQTT broker, and define
        the data and events to be published as MQTT messages.
- In the Setup Menu > Event Control > Event Overview dialog, the
        new event sensor type MQTT Subscription for receiving MQTT network
        messages can be selected and configured when adding message events.
For more information, see the program's online help
    
    
    
    Improvements in the area of integration protocols, ONVIF and RTP
      streaming
    The following improvements have been implemented in this area.
    RTP-RAW-Streaming
    
      - Support for additional mono camera models
 Raw streaming mode is now also supported for the following camera
        models:
        - Camera models with only one image sensor - Q71, D71, c71, p71, P71TA
          and v71
- Dual-sensor cameras with only one connected sensor
- Optical (non-thermal) image sensors on thermal camera
- 2 x 4K RTP RAW streaming
 Previously, only one of two 4K RTP video streams could be enabled on the
        Integration Protocols settings page (Admin menu > Camera
          Administration > Integration Protocols). This restriction
        has now been lifted so that customers are now able to retrieve RTP video
        streams from all available video encoders at the same time.
- Increased flexibility in RTP RAW streaming/mode
 The image source ("Full" or "Raw" streaming mode) of RTP video streams
        can now be configured individually for each video stream on the
        Integration Protocols configuration page (Admin menu > Camera
          Administration > Integration Protocols). In previous
        versions of the camera software, the image source could only be
        configured globally for all RTP video streams at the same time.
Integration Mode, ONVIF Fail-Over, and Genetec Settings
    
      - Configuration of RTP Video Encoder Parameters
 The Admin Menu > Camera Administration > Integration Protocols
        dialog now supports the configuration of video encoder parameters in the
        ONVIF, Genetec, and Genetec+ONVIF integration modes. In previous
        releases, the RTP video stream parameters could only be changed in
        compatible VMS clients.
- Audio streaming support for ONVIF failover recording
 The camera now also supports streaming recorded audio from ONVIF
        (failover) recordings to VMS systems. In previous versions of the
        camera's software, audio was recorded to the camera's SD card, but not
        streamed through the camera's RTP server.
- Support for Genetec audio alarm events
 Audio alarm events are now supported for Mx7 series cameras through the
        camera's Genetec integration API.
Other improvement
    
      - Microphone Event 
 An existing microphone can now be used to define a microphone event in
        the Environment Events section of the Setup
          menu > Event Control > Event Overview dialog. This
        applies to the integrated microphone in the audio and MultiSense module
        as well as to a connected microphone, the line-in connection of the S74
        audio IO plug-in card and the microphone of the mono models Q71, D71,
        c71, p71 and v71.
- New lenses (8° and F1.0)
 This version supports image sensor modules with the new super-telephoto
        lens (8° angle of opening) and the new very light-sensitive lens, which
        has an F1.0 aperture.
- OpenVPN client with SHA256
 In  the Admin Menu > Network Setup> OpenVPN Client
          Settings dialog, the value SHA256 can now also be
        selected for the Authentication option.
- Variables for digital input/output
 With the new variables $(SEN.IN1),$(SEN.OU1
        and $(SEN.OU2),
        the current status (value 0 or 1) of any digital inputs and outputs of a
        MOBOTIX 7 camera can be determined. As usual, the variables can be used,
        for example, to display the values in the live image or to transmit the
        values within a network message.
 ATTENTION: These variables replace the variables $(SEN.INA)
        to $(SEN.INP)!
- Variables for IR and white light illumination
 The following new variables can be used to determine the status of any
        connected or existing lighting modules.
        - $(SEN.LTA):
          Displays the status of an IR module connected to any camera port
- $(SEN.LT0...
            LT3): Displays the status of an IR module connected to camera
          port No. 1,... 4 
- $(SEN.IRR):
          Displays the value of the existing IR illumination ring on Q71, D71
          and indoor camera models
- $(SEN.WTR):
          Displays the value of the white light illumination ring on Q71 and D71
          cameras or a white light module connected on M73 and S74
In each case, the value 0 for a currently
      switched off and the value 1 for currently switched on lighting is
      returned.
    
      - Camera status with information about thermal sensor type (A
          and B)
 If thermal sensor modules are connected, the Camera Status
        dialog shows whether the sensor is type A or type B. This information is
        relevant because some functions are only supported for Type B thermal
        sensors.
- Double selection of the IR module
 An IR module connected to a camera port could  be selected in the Admin
          Menu > Hardware Configuration > Assign Wires dialog
        for the various options with both the IR Illuminator value and
        the IR Light:M<Port-No> value. This was confusing and now
        only the value IR Light: M<Port-Nr> is offered for
        selection.
Bugfixes
    
      - RTP streaming on 12MP sensors
        - When streaming 12 MP sensors via the camera's RTP
          server, the  maximum resolution UltraHD (2880x2880)
          was only available in full streaming mode if the
          stream was configured in the MxPEG codec. This is now also possible
          for H.264/H.265.
- When using the RTP server in raw streaming mode, the UltraHD
            (2880x2880) resolution was not available.
- Changing the camera time via the ONVIF API
 If a VMS client has changed the camera time via the ONVIF API, the
        camera has changed its time zone, even if the client did not request it.
        This could result in incorrect device time.
- Changing Video Motion Window via Genetec API
 In some cases, Video Motion windows configured through the Genetec
        Integration API were placed incorrectly and did not match the bounding
        box set in the Genetec Security Center.
- Stopping MxHUB ONVIF G Failover Recordings
 Cameras that are integrated into MxHUB via the ONVIF Integration API
        sometimes did not stop an ongoing ONVIF failover recording, even if
        MxHUB had previously reconnected to the camera.
- Registration of Smart Data Sources for MxManagementCenter
          (MxMC)
 After activating an App in the Setup Menu > Certified App
          Control > Certified App Settings dialog, the corresponding
        Smart Data Source is automatically added in the Admin Menu >
          Camera Configuration > Smart Data Configuration dialog.
        However, in order to transmit the information about the Smart Data
        Source to the MxMC for use in the MxMC's Smart Data Search, a camera
        restart was first required, this is no longer necessary.
- Using MxMessageSystem Event Profiles
 For certain special camera configurations, it was not possible to use
        more than one event profile of type MxMessageSystem .
- Configuration of the MxActivitySensor in the Japanese user
          interface
 When the Japanese user interface of the camera was set, the arrows for
        displaying the Left and Right  directions
        were reversed in the dialog for configuring the MxActivitySensor.
- Thermal variables for Full Image recording
 In the recorded images of a Full Image recording, the use of the
        following variables to determine different temperature values was
        incorrect:
          $(IMG. TRM. MIN.right), $(IMG. TRM. MAX.right), $(IMG. TRP.
          MIN.right), $(IMG. TRP. MAX.right). The values were not
        determined and entered in the image:
Known Limitations
    
      - Graphical definition
          of detection areas and windows
 Due to a cache error, it can happen in the web browsers Google Chrome
        and Firefox that no windows or polygons can be set. Only an error
        message is displayed. In this case, the camera can be opened in a
        private window and the configuration can be carried out there.
 
- A.I.Tech Apps and
          Thermal Sensors
 A.I.Tech's Certified Apps cannot currently be used for thermal module
        video streams.
- Softbutton LEDs
          Blink
 The soft button function LEDsBlink is without function
        and does not control the LEDs of the sensor modules.
- Changing the video codec for ONVIF recordings 
 Once the recording data for a particular ONVIF recording is stored, it
        is not currently recommended to change the video codec of the recording
        source. To change recording codecs for an ONVIF recording, it is
        recommended that you reformat the storage media
- Resolutions
          available via ONVIF API
 In some situations, the ONVIF integration API does not report
        all resolutions supported by an RTSP video stream to the camera. In most
        cases, this happens when the codec of an RTP video stream or the RTP
        server's aspect ratio is reconfigured.
 Workaround: After restarting the camera or briefly changing
        the integration mode, all resolutions should be offered again.
      - RTP server
          configuration after configuration via ONVIF API
 Occasionally, the camera's RTP server configuration is not updated
        correctly when parts of ONVIF media profiles (called "configurations")
        are replaced, removed, or added by an ONVIF VMS client. This can lead to
        the following different effects, for example:
      - Incorrect configuration values are displayed in the respective ONVIF
        VMS client
- RTP video, audio, or metadata streams are not displayed as configured
        or are not displayed at all.
- RTP streams that contain sub-streams, e.g. a metadata stream that was
        previously removed from the respective ONVIF media profile.
Workaround: If this issue
      occurs, customers should restart the camera and check the camera
      configuration again. If the camera configuration is still incorrect after
      restarting the camera, customers should try repeating the configuration
      changes or, if necessary, re-registering the camera in their VMS client
    
     
     
     
     
     
     
     
     
    
    top
     
    Software Release MX-V7.3.1.60 − for M7 Camera Models M73, S74, Q71, D71,
      c71, p71, p71TA, v71
    Creation Date: 2023-01-27
    Publishing Date: 2023-02-03
    
      Important notes on installation
      
        -  This version supports
            all MOBOTIX 7 camera models. They are all updated with the same file
            MX_system_7_3160.mpl
              from the Services > Download Center > All
              software downloads > cameras > MX system release 7.3.1.60 section
            of the MOBOTIX website (https://www.mobotix.com). 
- 
          If you are using Certified Apps in the camera,
            you must update them using the MX_preinstalled_apps_2023-01-27.app
            package from the Services > Download Center
              > All Software Downloads > Certified Apps section
            of the MOBOTIX website (https://www.mobotix.com). This
            package also includes the App MOBOTIX Analytics with
              AI/deep learning-based object recognition. 
 
    
    Enhancements and improvements
    
    Support of the camera model p71 Thermal ECO
    With this version, the new camera model p71 Thermal ECO is supported.
      This is an affordable basic thermal solution for indoor use, which has a
      wide viewing angle and covers various basic applications. These include,
      for example, perimeter and burglary protection as well as temperature
      monitoring. 
    
    
    
    S74 camera with Long Cable Extender and 12MP sensor modules
    When connecting a Long Cable Extender (LCE) to a camera port of a S74
      camera, the connection and operation of a 12MP sensor module to the LCE is
      now also supported. For that purpose, in the web browser, the value
        Long (> 2 meters) must  be selected for the Cable
        length option in the Admin > Hardware Configuration
        > Sensor Module Configuration dialog.
    
    Certified Apps with improved support for the Smart Data interface to
      MxManagementCenter
    Along with this version of the camera software, a new Certified App
      Package 'MX_preinstalled_apps_2023-01-27.app' was also released. This
      package contains all Certified Apps, including the MOBOTIX Analytics App
      with AI/deep learning-based object recognition. Compared to the previous
      version 2022-11-28, it contains improvements of the Smart Data interface
      to the MxManagementCenter (MxMC). Details on the exact contents of the
      package and the changes can be found in the release notes for the package
      in the Services > Download Center > All Software Downloads
        > Certified Apps > MX Certified Apps Release 2023-01-27 section
      of the MOBOTIX website (https://www.mobotix.com).
    
    Known Limitations
    
      - S74 cameras and
          MultiSense module
 When operating a MultiSense module on a S74 camera, the light sensor of
        the module cannot be read out after a camera restart. In this case, no
        lux value for the Multisense is displayed in the Camera Status dialog in
        the Sensors area and events in the definition of which the illumination
        values of this sensor are used no longer trigger!
 
- A.I.Tech Apps and
          Thermal Sensors
 A.I.Tech's Certified Apps cannot currently be used for thermal module
        video streams.
- Softbutton LEDs
          Blink
 The soft button function LEDsBlink is without function
        and does not control the LEDs of the sensor modules.
- Microphone Event
 Currently, no microphone event is supported. This applies to the
        built-in microphone in the Audio and MultiSense module as well as to a
        connected microphone, to the Line-In connector of the S74 Audio IO board
        and to the new Q71 model.
- RTP streaming
        - When streaming 12 MP sensors via the camera's RTP
          server in Full Streaming Mode,  the maximum
          resolution in the aspect ratio "1:1" (2880x2880) is currently only
          available if the stream is configured to the MxPEG codec.
- When using the camera's RTP server in Raw Streaming Mode,
          the "UltraHD" resolution is only available on 4K
          Optical sensors. "UltraHD" is not supported on 12MP and 4MP ULL
          optical sensors.
- On MOBOTIX 7 single lense cameras
          (Q71, D71, c71, p71, v71) the RAW mode is currently disabled and is
          not supported.
- Changing the video codec for ONVIF recordings 
 Once the recording data for a particular ONVIF recording is stored, it
        is not currently recommended to change the video codec of the recording
        source. To change recording codecs for an ONVIF recording, it is
        recommended that you reformat the storage media
 
     
     
     
     
     
     
     
    
    top
     
    Software Release MX-V7.3.1.57 − for M7 Camera Models M73, S74, Q71, D71,
      c71, p71, v71
    Creation Date: 2022-11-28
    Publishing Date: 2022-12-01
    
      Important notes on installation
      
        -  This version supports
            all MOBOTIX 7 camera models. They are all updated with the same file
            MX_system_7_3157.mpl
              from the Services > Download Center > All
              software downloads > cameras > MX system release 7.3.1.57 section
            of the MOBOTIX website (https://www.mobotix.com). 
- 
          If you are using Certified Apps in the camera,
            you must update them using the MX_preinstalled_apps_2022-11-28.app
            package from the Services > Download Center
              > All Software Downloads > Certified Apps section
            of the MOBOTIX website (https://www.mobotix.com). This
            package also includes the App MOBOTIX Analytics with
              AI/deep learning-based object recognition. 
 
    
    Enhancements and improvements
    
    Image Quality Improvement
    In this version, both the factory settings and many internal parameters
      important for image generation have been fundamentally revised. Thus, this
      software delivers much better images in many lighting situations than the
      previous versions. This is especially true for dark scenes and manifests
      itself in both improved image sharpness and lower image noise.
    Improvements and changes in the area of Certified Apps
    Improvements to the Smart Data Interface for MxManagementCenter (MxMC)
      from version 2.7
    The configuration steps required for a system administrator to search and
    display App result data from an Mx7 camera integrated into the
    MxManagementCenter have been significantly simplified: 
    
      - After activating an App in the camera, it automatically enters a
        suitable Smart Data source in the Admin > Camera
          Administration > Smart Data Configuration dialog. In
        principle, the Smart Data interface only has to be activated once.
- In the MxManagementCenter, the camera can then use the new Get
          Camera Apps function to retrieve the internally required
        information about the activated Apps of an integrated Mx7 camera.
- The corresponding Smart Data sources are then automatically entered
        into the list available in the MxManagementCenter and the user can
        search directly for result data from these Apps in the Smart Data search
        of MxMC. 
    
    Updated and new Certified Apps
    Along with this version of the camera software, a new Certified App
      Package 'MX_preinstalled_apps_2022-11-28.app' was also released. This
      package contains all Certified Apps, including the MOBOTIX Analytics App
      with AI/deep learning-based object recognition. Compared to the previous
      version, it includes the following new apps:
    
      - MOBOTIX Advanced Radiometry (for the detection of
        temperature events)
- Mobotix Barcode Reader (for reading 1D and 2D
        barcodes)
- Vaxtor Genesis (for generic searching for defined
        texts)
In addition, some existing Apps from MOBOTIX,
      Visage Technologies and Vaxtor have
      been  replaced by new, improved versions. Details on the exact
      contents of the package and the changes can be found in the release notes
      for the package in the Services > Download Center > All
        Software Downloads > Certified Apps > MX Certified Apps Release
        2022-11-28 section  of the MOBOTIX website
      (https://www.mobotix.com).
    In addition, this version supports the new Mobotix Thermal Heat
        Detection App, which is currently only available with a French
      user interface and can be downloaded separately from the MOBOTIX website.
    
      Notes on using the apps together with the
        MxManagementCenter (MxMC)
      
        - The smart data interface improvement mechanism described above is not
            currently supported for A.I.Tech and Irisity Apps. For all
          other Apps, this automatism has been implemented in the latest
          versions of the App package 2022-11-28.
- To use the automatism in MxManagementCenter,
          version 2.7 of MxMC or higher is required.
      Due to the changes to the configuration of the Smart Data interface
      described above, the following restrictions apply when using Apps from 
App Package 2022-11-28 together with
        MxMC version V2.6.1 or lower:
      
        - The data of the App VT_Face.face by Visage
          Technologies Face Recognition cannot
            be displayed!
- For the remaining Apps, after activating an App in the camera for
          the first time, the name of the Smart Data Source automatically
          entered for this App in the Admin > Camera Administration
            > Smart Data Configuration dialog, must be supplemented
          by an appendix ".plate", ".vehicle", etc. , according to the following
          list:
          - FFLPR.plate
- FFLPRAM.plate
- FFLPR_MMCR.vehicle
- FFLPRME.plate
- VaxALPR.plate
- VaxALPRADR.plate
 
- VaxALPRMMC.vehicle
- VaxOCRContainer.container
- VaxOCRUIC.uic 
- VaxUSDOT.plate
- This is not necessary for Apps that were already activated before
          the update and whose name is therefore already fully entered in the
          list.
- For subsequent changes in the Setup > Control for
            Certified Apps > Settings for Certified Apps dialog,
          pressing the Set button causes all FFGroup and
          Vaxtor Apps active in the dialog to be automatically entered back into
          the list of Smart Data sources in the Admin > Camera
            Administration > Smart Data Configuration dialog, in
          each case without the appendix ".plate", ".vehicle", etc.. These
            entries must be manually removed from the list, otherwise an
          error will occur when displaying the associated data in the Smart Data
          search.
 
    Other improvements
    
      - Event Player
 The function icons in the Event Player view have been adapted to match
        the icons used in this view in the Mx6 camera line and are therefore
        easier to understand.
- Focusing aid
 After activating the focusing aid in the camera Quick Controls, a window
        can now be defined with the mouse in the image, the contents of which
        are then used for focusing.
- Counting Corridors of the MxAnalytics App
 When configuring counting corridors for the MOBOTIX Analytics App, the
        names for the flow directions are no longer limited to North
        and South , but can be assigned arbitrarily. In addition,
        deactivating the new option Count Counter Direction
        means that the passes in the direction of South are no longer
        counted and output in the report.
- FTP directory names
 When using FTP Transfer Profiles, the characters '&' and ' ' can now
        also be used in the FTP folder names.
Bugfixes
    
      - Camera mode
 When changing  the camera mode in the Admin > Hardware
          Configuration  > Camera Mode dialog, it could happen
        after a camera restart using the Reboot Camera
        function in the same dialog that the mode was not applied completely and
        partly displayed incorrectly.
- Setting time and date via ONVIF
 When setting the system time and date for a camera integrated via the
        ONVIF protocol using the SAOP Action SetSystemDateAndTime()
        without specifying the time zone, the  time zone in the camera was
        also changed to the value "Custom/Posix", which subsequently led to
        error effects
- Dialog Setup Menu > Certified App Control > Certified
          Apps Settings
 After the first activation of the Arming option in the
        above dialog, the check boxes for activating the individual Apps were
        not displayed. After reloading the dialog, they were then available.
Known Limitations
    
      - S74 cameras and
          MultiSense module
 When operating a MultiSense module on a S74 camera, the light sensor of
        the module cannot be read out after a camera restart. In this case, no
        lux value for the Multisense is displayed in the Camera Status dialog in
        the Sensors area and events in the definition of which the illumination
        values of this sensor are used no longer trigger!
 
- A.I.Tech Apps and
          Thermal Sensors
 A.I.Tech's Certified Apps cannot currently be used for thermal module
        video streams.
- Softbutton LEDs
          Blink
 The soft button function LEDsBlink is without function
        and does not control the LEDs of the sensor modules.
- Microphone Event
 Currently, no microphone event is supported. This applies to the
        built-in microphone in the Audio and MultiSense module as well as to a
        connected microphone, to the Line-In connector of the S74 Audio IO board
        and to the new Q71 model.
- RTP streaming
        - When streaming 12 MP sensors via the camera's RTP
          server in Full Streaming Mode,  the maximum
          resolution in the aspect ratio "1:1" (2880x2880) is currently only
          available if the stream is configured to the MxPEG codec.
- When using the camera's RTP server in Raw Streaming Mode,
          the "UltraHD" resolution is only available on 4K
          Optical sensors. "UltraHD" is not supported on 12MP and 4MP ULL
          optical sensors.
- On MOBOTIX 7 single lense cameras
          (Q71, D71, c71, p71, v71) the RAW mode is currently disabled and is
          not supported.
- Changing the video codec for ONVIF recordings 
 Once the recording data for a particular ONVIF recording is stored, it
        is not currently recommended to change the video codec of the recording
        source. To change recording codecs for an ONVIF recording, it is
        recommended that you reformat the storage media
 
     
     
     
     
     
     
     
    
    top
     
    Software Release MX-V7.3.1.46 − for M7 Camera Models M73, S74, Q71, D71,
      c71, p71, v71
    Creation Date: 2022-09-01
    Publishing Date: 2022-09-09
    
      Important notes on installation
      
        -  This version supports
            all MOBOTIX 7 camera models. They are all updated with the same file
            MX_system_7_3146.mpl
              from the Support > Download Center > All
              software downloads > cameras > MX system release 7.3.1.46 section
            of the MOBOTIX website (https://www.mobotix.com). 
- 
          If you are using Certified Apps in the camera,
            you must update them using the MX_preinstalled_apps_2022-09-01.app
            package from the Support > Download Center > All
              Software Downloads > Certified Apps section of the
            MOBOTIX website (https://www.mobotix.com). This
            package also includes the App MOBOTIX Analytics with
              AI/deep learning-based object recognition. 
 
    
    Enhancements and improvements
    
    Support indoor models c71, p71 and v71
    This software version also supports the new Mx7 indoor camera models c71,
        p71 and v71. In contrast to the outdoor
      models of the Mx7 camera line, these models can also be operated with PoE
      Class 3. To activate this energy-saving mode, a small switch on the camera
      board, right next to the RJ45 socket, must first be set to position "1"
      and then the PoE class 3 must be set in the web user interface. For this
      purpose, in the Admin Menu > Network Configuration  >
        Ethernet interface dialog, in the Ethernet Hardware
        Options section, there is the Configure PoE function
      button.  With its help, another dialog Power
        over Ethernet (PoE) is opened and there the setting of the Power
        Supply option can be changed  to the value Power
        over Ethernet (Class 3).
     
     
     
    Notes on operation
        in PoE class 3
      
        - The IR LEDs of the camera are operated in this
          operating mode only with reduced power consumption and produce a lower
          brightness.
- The new USB Power Output function (see below)
          cannot be activated in this mode in the Admin Menu > Manage
          Hardware Configuration > Hardware Extensions dialog.
 
    Whitelight module support for M73 and S74 cameras
    This firmware version supports the new Whitelight module for M73 and S74
      cameras. Depending on the variant, the High Power LED module can
      illuminate an area around the camera with a distance of up to 80 m and
      thus significantly increase the image quality. After connecting a
      Whitelight module to one of the camera ports, just like an IR Light
      module, it can be used in the Admin Menu > Hardware
        Configuration > Assign Wires dialog, by selecting the value
      White Light: M<Port No> for the Lights or
      IR Lights option, for illumination after automatic
      day-night switching. In the Signal Out Profiles dialog,
      it can also be used to define Signal Output Profiles by selecting the same
      value for the Signal Out Action(SO) option and thus
      switched on/off in response to any events.
     
     
     
     
    Notes on the use
        of Whitelight and IR light modules
      
        - For several light modules connected to the camera (Whitelight and/or
          IR modules), in the Admin Menu  > Hardware
            Configuration > Assign Wires dialog, as a value for the
          options Lights or IR Lights in
          addition to a specific light module, depending on the module type also
          the value WL Illuminator, IR Illuminator or WL+IR
            Illuminator can be selected. In this case, all connected light
          modules are activated simultaneously after a day-night switch
            for illumination.
- The same applies analogously to the selection of light modules in
          the Signal Out Profiles dialog. There, too, a
          specific module or all light modules connected to the camera can be
          selected for use in Signal Out Profiles . An associated event then
          also triggers an activation of all connected light modules at the same
          time.
 
    Improvements of the Storage Failure Detection
    
      - Monitoring of retention time
 With the help of the new Time to Keep option in the General
          Settings area of the Admin Menu > Storage >
          Storage Failure Detection dialog, the retention time set by
        the Time to Keep option in the Admin Menu
          > Storage > Storage on External File Server / Flash Device
        dialog can be monitored. If the retention time cannot be reached, e.g.
        because the existing storage area of the file server used is not
        sufficient and the recording therefore is running round before the
        retention time is reached, a notification and output of a message takes
        place in the log file of the Memory Failure Monitoring
        dialog.
- SD Card Flash Wear and I/O Error Messages
 After activating the SD card I/O option in the General
          Settings section of the Admin Menu > Storage >
          Storage Failure Detection  dialog, critical system
        error messages are displayed as soon as the flash wear has reached 100%.
        In addition, this option causes the notification of SD card I/O errors
        and the output of messages for I/O errors in the log file of the
        above-mentioned dialog.
- Monitoring the MxFFS Archive Buffer
 Activating the new Buffer MxFFS Archive option in the
        the General Settings section of the Admin
          Menu > Storage > Storage Failure Detection dialog
        monitors the SD card transfer buffer when stored in a (buffered) MxFFS
        archive. When storing in a MxFFS archive with the SD card as the primary
        target, a message is notified and output in the log file of the Storage
          Failure Detection dialog as soon as the SD card has a level
        of 120MByte. The messages are sent until the level has fallen below
        80MByte again. When stored in a buffered MxFFS archive, the notification
        and message output take place as soon as the data is stored on the SD
        card instead of directly in the archive.
Thermal Camera Enhancements
    
      - Ambient temperature for thermal cameras 
 Decimal values can now also be specified for the Ambient
          Temperature to be set in the Temperature
          Compensation area of the Setup Menu > Thermal
          Sensor Settings dialog.
- SNMP OIDs for Thermal TR Measurement Windows
 For Thermal TR cameras, an additional table object statusThermalRadiometryTemperatureTable,  which is specified in
        the MOBOTIX SNMP MIB file, is now returned via SNMP. This contains,
        among others, the values of the measured temperature for each defined
        temperature measurement window. Depending on the set Comparison
          Type of the TR event, the maximum or minimum measured
        temperature is transmitted.
Updated Certified Apps
    Along with this version of the camera software, a new Certified app
      package 'MX_preinstalled_apps_2022-09-01.app' has also been released. This
      package contains all Certified Apps, including the MOBOTIX
        Analytics app with AI/Deep Learning-based object recognition. 
      Compared to the previous version, it includes some improved
        versions of the Apps from MOBOTIX, Visage Technologies and Vaxtor.
      Details on the exact content of the package and the changes can be found
      in the release notes for the package in the Support > Download
        Center > All Software Downloads > Certified Apps > MX Certified
        Apps Release 2022-09-01 section of the MOBOTIX website
      (https://www.mobotix.com).
    Other improvements
    
      - USB Power Output
 In the Admin Menu > Hardware Configuration > Manage
          Hardware Expansions dialog, it is possible to set the USB
          Power Output operating mode in the USB Connector area.
        By activating a previously configured USB Power Output, a device
        connected to the camera USB port, such
        as an
        IR radiator
        powered by
        USB, is supplied with a voltage
        of 5V by the camera via the USB interface. The activation can be done by
        an automatic day-night-switch or by executing a corresponding Signal Out
        Profile, for example after an assigned event. The required configuration
        is done in the Admin Menu >  Hardware Configuration
          > Assign Wires or in the Signal Out Profiles
        dialog by selecting the value Camera: USB Power for the
        corresponding option.
- Improved App stability
 When using Certified Apps of the Mx7 camera line, there could be
        internal camera stability problems. This was especially true for the use
        of several Apps at the same time and manifested itself in the following
        error behavior
        - The list of activatable Apps in the Setup Menu >
            Certified App Control > Certified App Settings dialog
          remained empty and no Apps could be configured. After a camera
          restart, they were available again .
- The transmission of the App result data and its display in the
          MxManagementCenter (MxMC) using the Smart Data Interface no longer
          worked. In this case, a camera restart was necessary before camera App
          data could be searched for and displayed again in the MxMC. 
This behavior has now been fundamentally
      improved so that the Apps can be displayed and used in a stable way.
    Bugfixes
    
      - S74 cameras and
          MultiSense module
 When operating a MultiSense module on an S74 camera, it could happen
        after a camera restart that values for the PIR and temperature sensor
        could no longer be read by the camera and thus defined events could no
        longer be triggered. This has been corrected and there is still a
        restriction with the light sensor (see below).
- Q71 Installation
          Mode
 Setting the Installation option  in  the
        vPTZ area of the Quick Controls to the Wall or Floor
        values was incorrect in some cases.
- Bugfixes in the area of day-night
          switching and IR illumination
        - Day-night switching
            for IR-Cut Day & Night Sensor Modules
 Especially with ULL sensor modules with IR-Cut filter, the factory-set
          automatic day/night switching (options IR-Cut Filter and
          Light Switch) could lead to the camera running permanently in night or
          day mode after a switching process and having to be switched manually.
- Profiles ~IRLightON,
              ~IRLightOFF, ~IRLightToggle not usable
 When defining action groups, the internal Signal Out profiles  ~IRLightON,
            ~IRLightOFF, ~IRLightToggle could not be selected for
          actions if no MX-232-IO box or S74 IO slide-in boards were connected
          to the camera.
- Using the Signal Out
            for day-night switching
 In  the Admin Menu > Hardware Configuration >
            Assign Wires dialog, the use of the Value Camera: Out
          for the IR Lights option was incorrect and thus the Signal Out
          could not be used to switch on for example an external IR emitter
          after switching to night mode.
- LPF sensors and IR
            illumination
 The use of an LPF sensor did not result in the internal Signal Out
          Profile ~IRLightOn
          being permanently activated and thus permanently switching on a
          corresponding IR emitter or a built-in IR light module, as is
          necessary for the use of an LPF sensor.
- Day-night switching
            for separate sensors
 In the "classic" day-night switching between a color and a
          black-and-white sensor module, switching on the light source selected
          in the Admin > Hardware Configuration > Assign Wires dialog
          for the IR Lights  option did not work after
          switching to night mode.
- Multisense
          illumination value in camera status
 The  lux value displayed  in the Camera Status
        dialog in the Sensors area for a connected Multisense
        module was incorrect.
- Definition of SIP
          accounts
 When defining SIP accounts in the Admin Menu > Audio and
          VoIP Telephony > SIP Server Settings dialog, the error
        message 'Error: SIP addresses and user names must be unique.' could
        occur despite valid entries.
- Changing the Camera
          Mode
 Switching the Camera Mode in the Admin Menu
          > Hardware Configuration > Camera Mode dialog from Streaming
        to AI or vice versa was sometimes not performed correctly if
        the subsequent necessary camera restart was not performed manually, but
        via the Reboot link available in the dialog.
Known Limitations
    
      - S74 cameras and
          MultiSense module
 When operating a MultiSense module on a S74 camera, the light sensor of
        the module cannot be read out after a camera restart. In this case, no
        lux value for the Multisense is displayed in the Camera Status dialog in
        the Sensors area and events in the definition of which the illumination
        values of this sensor are used no longer trigger!
 
- A.I.Tech Apps and
          Thermal Sensors
 A.I.Tech's Certified Apps cannot currently be used for thermal module
        video streams.
- Dialog Setup Menu
          > Certified App Control > Certified Apps Settings
 After the first activation of the Arming option in the
        above dialog, the check boxes for activating the individual Apps are not
        displayed. After reloading the dialog, they are then available.
- Online help for App
          dialogs
 Online help is currently only partially available in the dialogs for
        configuring the Certified Apps.
- Softbutton LEDs
          Blink
 The soft button function LEDsBlink is without function
        and does not control the LEDs of the sensor modules.
- Microphone Event
 Currently, no microphone event is supported. This applies to the
        built-in microphone in the Audio and MultiSense module as well as to a
        connected microphone, to the Line-In connector of the S74 Audio IO board
        and to the new Q71 model.
- RTP streaming
        - When streaming 12 MP sensors via the camera's RTP
          server in Full Streaming Mode,  the maximum
          resolution in the aspect ratio "1:1" (2880x2880) is currently only
          available if the stream is configured to the MxPEG codec.
- When using the camera's RTP server in Raw Streaming Mode,
          the "UltraHD" resolution is only available on 4K
          Optical sensors. "UltraHD" is not supported on 12MP and 4MP ULL
          optical sensors.
- On MOBOTIX 7 single lense cameras
          (Q71, D71, c71, p71, v71) the RAW mode is currently disabled and is
          not supported.
 
     
     
     
     
     
     
     
    
    top
     
    Software Release MX-V7.3.1.31-r3 − for M7 Camera Models M73, S74, Q71,
      D71
    Creation Date: 2022-06-28
    Publishing Date: 2022-06-30
    
      Notes on Release MX-V7.3.1.31-r3
      
        -  This version differs from the previous version 7.3.1.31-r1
          only in the bug fixes described below for this version.
Notes on Release MX-V7.3.1.31-r1
      
        - This release is different from its predecessor release 7.3.1.31 only in improved
          support for the Irisity App from the Certified
            Apps 2022-06-02 App
          package and an improved online help for the Admin Menu >
            Camera Administration > Integration Protocols dialog.
 
    
      Important notes on installation
      
        -  This version supports
            all MOBOTIX 7 camera models. They are all updated with the same file
            MX_system_7_3131_r2.mpl
              from the Support > Download Center > All
              software downloads > cameras > MX system release 7.3.1.31-r3
            section of the MOBOTIX website (https://www.mobotix.com).
        
- 
          If you are using Certified Apps in the camera,
            you must update them using the MX_preinstalled_apps_2022-06-21.app
            package from the Support > Download Center > All
              Software Downloads > Certified Apps section of the
            MOBOTIX website (https://www.mobotix.com). This
            package also includes the App MOBOTIX Analytics with
              AI/deep learning-based object recognition. 
 
    
    Enhancements and improvements
    
    ONVIF-G
    With this software version, the M7 camera models support the ONVIF-G
      standard. This allows these cameras to use the ONVIF-G protocol to
      configure edge recording on the camera's internal SD card and then access
      the data stored in this way. Some video management systems, such as e.g.
      MOBOTIX HUB, use this function to implement a so-called "fail-over
      recording". With that the failure of a storage server is briefly bridged
      by an edge recording on the camera.
     
     
     
    
      Notes on ONVIF-G
        
      
        - In this software version, the recordings are
          stored by edge recording on the camera's internal SD card in the same
          area as the data from activated Apps, i.e. in the User Data
          partition. This will be changed in a subsequent software version and
          the size of the area on the SD card available for edge recording will
          be adjustable.
- For newly delivered cameras, the partition is already available ex
          works. For older cameras with a software version earlier than 7.2.1.29
          or when replacing the SD card, the SD card must be reformatted and
          this partition created.
- It is not possible to record or access an external
            file server or flash media (USB stick, SDD drive) using
          ONVIF-G.
- Currently, the ONVIF G edge recording supports
          the video codecs H.264 and H.265. The MJPEG and
          MxPEG codecs are not supported.
- Currently, it is not possible to stream audio
            data via the ONVIF-G interface in addition to video.
- Once recording data have been stored for a
          particular ONVIF recording, switching the video codec
          of the recording source is currently not recommended.
 To switch recording codecs for an ONVIF recording, it is recommended
          to format the storage medium.
 
    Updated and new Certified Apps
    Along with this version of the camera software, a new Certified App
      package 'MX_preinstalled_apps_2022-06-21.app'
      has also been released. This package contains all Certified Apps,
      including the MOBOTIX Analytics App with AI/Deep
        Learning-based object recognition.  Compared to the
      previous version, it also includes revised versions of the Apps
        from FFGroup, Vaxtor and Iristy, a new App
      from Vaxtor (USDOT) as well as two new Apps
      from MOBOTIX for color recognition (Mobotix
        Color Recognition) and AI-based motion detection (Mobotix
        ActivitySensor). Details on the exact content of the package
      and the changes can be found in the release notes for the package in the Support
        > Download Center > All Software Downloads > Certified Apps
        > MX Certified Apps Release 2022-05-31 area of the MOBOTIX
      website (https://www.mobotix.com).
    Other improvements
    
      - SNMP support
 With this version, SNMP clients can also receive various
        temperature values from thermal cameras via the SNMP protocol. The
        SNMP-MIB file of the camera has been extended by corresponding OIDs 'MOBOTIX-MIB::statusThermal*'.
- Maximum text font size
 The maximum size of the text fonts for text overlays in the
        live image or image profiles has been increased from 24pt to 48pt.
- Online help Integration Protocols
 The online help of the dialog Admin
          Menu > Camera administration > Integration Protocols has
        been expanded and improved in many places.
Bugfixes
    
      - PoE switches with
          PoE class3 (correction in 7.3.1.31-r3)
 For network switches that return an incorrect PoE class (PoE3 instead of
        PoE+) during the negotiation phase, the camera version 7.3.1.31-r1 did
        not support the operation of additional resources such as an IR module.
 
- IR module with LPF
          sensor module (correction in V7.3.1.31-r3)
 The operation of an IR module together with an LPF sensor module was not
        possible in version 7.3.1.31-r1.
 
- Update of older
          software versions with activated App Object Recognition (correction
        in V7.3.1.31-r3)
 If an older software version was updated to version 7.3.1.31 or
        7.3.1.31-r1 on a camera with App Object Recognition
        enabled, without first disabling this App and resetting the camera to
        "Streaming" mode, some combinations of firmware and App version could
        lead to problems: the camera then restarted again and again after a few
        seconds of uptime.
 
- Further
          WDR improvements
 In special lighting situations, the following effects could still occur
        when WDR is activated: short-term black image, unstable exposure
        control, image flickering (fast change between brighter and darker image
        with increased MxPEG rate).
- Camera restarts when
          combining Apps and thermal modules
 For cameras with a thermal module connected to Port1 or Port2,
        activating the Certified Apps led to a regular (every 5min) restart of
        the camera.
- Day-night switching
          for IR-Cut Day & Night Sensor Modules 
 Depending on the software version, the factory-set automatic day/night
        switching (options IR-Cut Filter and Light
          Switch) for IR-Cut Day & Night sensor modules could lead
        to the cameras running permanently in night mode (from V7.2.1.x on) or
        day mode and had to be switched manually.
- Variables $(SEN.
            TC0. CELSIUS),... $(SEN. TC3. CELSIUS) in image profiles
 The temperature variables $(SEN.
          TC0. CELSIUS),... $(SEN. TC3. CELSIUS)to display the
        temperature, e.g. of a MultiSense module, were not displayed with their
        current values but empty when used in image profiles.
- Camera mode AI and
          exposure settings
 When operating the camera in AI mode, not all options were
        available in the Setup Menu > Image Control > Exposure
          Settings dialog. Among other things, the definitions of the
        exposure windows were missing.
- Dark page layout and
          formatting wizard
 When using the Dark Theme in the camera's
        graphical user interface, some options were difficult to see in the
          Formatter Wizard: MxFFS Volume Partitioning dialog.
- System messages for
          LPF sensor modules
 During the operation of LPF sensor modules, incorrect entries "EVENT IR
        Light Switched on" occurred in the system messages.
- Activation of a
          MultiSense PIR event in the MxMC
 The PIR sensor of a MultiSense module connected to the camera could not
        be used to activate PIR-events in the camera by the MxManagementCenter.
Known Limitations
    
      - S74 cameras and
          MultiSense module
 When operating a MultiSense module on a S74 camera, the sensors of the
        MultiSense module may no longer deliver values to the camera after a
        camera restart.
 
- A.I.Tech Apps and
          Thermal Sensors
 A.I.Tech's Certified Apps cannot currently be used for thermal module
        video streams.
- Dialog Setup Menu
          > Certified App Control > Certified Apps Settings
 After the first activation of the Arming option in the
        above dialog, the check boxes for activating the individual Apps are not
        displayed. After reloading the dialog, they are then available.
- Online help for App
          dialogs
 Online help is currently only partially available in the dialogs for
        configuring the Certified Apps.
- Softbutton LEDs
          Blink
 The soft button function LEDsBlink is without function
        and does not control the LEDs of the sensor modules.
- Microphone Event
 Currently, no microphone event is supported. This applies to the
        built-in microphone in the Audio and MultiSense module as well as to a
        connected microphone, to the Line-In connector of the S74 Audio IO board
        and to the new Q71 model.
- RTP streaming
        - When streaming 12 MP sensors via the camera's RTP
          server in Full Streaming Mode,  the maximum
          resolution in the aspect ratio "1:1" (2880x2880) is currently only
          available if the stream is configured to the MxPEG codec.
- When using the camera's RTP server in Raw Streaming Mode,
          the "UltraHD" resolution is only available on 4K
          Optical sensors. "UltraHD" is not supported on 12MP and 4MP ULL
          optical sensors.
- On MOBOTIX 7 single lense cameras
          (Q71, D71) the RAW mode is currently disabled and is not supported.
 
     
     
     
     
     
     
     
    
    top
     
    Software Release MX-V7.3.0.54 − for M7 Camera Models M73, S74, Q71, D71
    Creation Date: 2022-03-03
    Publishing Date: 2022-03-04
    
    
      Notes on Release MX-V7.3.0.54
      This release is different from its predecessor release 7.3.0.53
        only in a bugfix concerning the image sensor control on Q71
        camera models.
     
    
      Important notes on installation
      
        - 
          This
              version supports all MOBOTIX 7 camera models. They are all updated
              with the same file MX_system_7_3054.mpl from the Support
                > Download Center > All software downloads > cameras
                > MX system release 7.3.0.54 section of the MOBOTIX
              website (https://www.mobotix.com). 
- 
          If you are using Certified Apps in the camera,
            you must update them using the MX_preinstalled_apps_2022-02-16.app
            package from the Support > Download Center > All
              Software Downloads > Certified Apps section of the
            MOBOTIX website (https://www.mobotix.com). This
            package also includes the App MOBOTIX Analytics with
              AI/deep learning-based object recognition. 
 
    
    Enhancements and improvements
    Support for the new Q71-Hemispheric camera model
    This version supports the new MOBOTIX 7 camera model Q71-Hemispheric.
      The camera has a 12-mega-pixel image sensor with integrated IR cut filter,
      a hemispheric lens, microphone and speaker, as well as integrated LEDs for
      IR and White Light Illumination. Compared to the M73 and S74 camera
      models, the following software functions are available: 
    
      - Setting of different Display Modes with 
            automatic image
            correction (Normal,
            Surround, Panorama, Panorama Focus, Double Panorama) in the Quick Controls  or
          in  the Setup
            Menu > Image Control > General Image Settings dialog
- Selection of additional resolutions
          (12MP 1:1 (2880x2880), UltraHD2(2144x2144),
            FullHD2(1080x1080), HD2  1:1(768x768), nHD21:1(360x360))
          in the Quick-Controls or
          in the Setup Menu > Image Control > General Image Settings dialog
- Setting of the installation (wall,
            ceiling, floor) in the vPTZ
          area of the  Quick
            Controls
- Activation of the
            integrated IR and White Light LEDs
 These
          integrated illuminations are activated in the Admin Menu >
            Hardware Configuration > Assign Wires dialog. In
          the factory settings, the options are set as follows:
        - Lights = White Light Ring
- IR Lights =
            IR Light Ring
With this
        setting, IR illumination is used after an automatic day-night switching
        (also factory set) in night mode. If White Light Illumintaion is to be
        used in night mode and the camera shall continue to produce a color
        image, the following options must be set:
    
      
        - IR Lights = White Light Ring
- IR-Cut-Filter = IR-Filter-On (in the Setup Menu
            dialog > Image Control > General Image Settings)
For
        testing and quick switching on/off the two types of lighting, two
        suitable Shortcuts  are also
        defined  ex works in the title bar of the web browser's live
        view (see section "Shortcuts
          for soft button functions" below).
        are also
        defined  ex works in the title bar of the web browser's live
        view (see section "Shortcuts
          for soft button functions" below).
    The other software functions are
        identical to those of the M73 and S74 models.
    
    
    
      Note:
      This software version only supports MOBOTIX Analytics on the Q71 as a
      Certified Apps, currently without Behavioral Detection.
 
    Support of the new camera model D71 - Single Lens Dome 
    This
        version supports the new MOBOTIX 7 camera model D71 - Single Lens Dome.
        The camera is available with a 4K UHD or 4MP ULL sensor, each with
        integrated IR cut filter, has a 3-axis pan-tilt head (manual
        adjustment), microphone and speaker, and integrated IR illumination. The
        activation of the integrated IR illumination also succeeds
        here in the Admin Menu  >
            Hardware Configuration > Assign Wires dialog.
        From the factory, the IR
          Lights option is already set to the value IR Light Ring and thus the IR
        illumination is automatically used to generate the black and white
        images in night mode.
    The other software functions are identical to those of
      the M73 and S74 models.
     
    
      Note on the Certified Apps:
      To configure the Certified Apps, a sensor selection is currently also
      offered for this camera model. Here the 
right image sensor or
      the setting 
Auto must  be selected. This will be fixed with
      an upcoming firmware version 7.3.x
    
 
    Support of the new hemispheric 12MP sensor modules
    For use with an S74 camera, there
        are now also hemispheric sensor modules with a resolution of 12MP and
        integrated IR cut filter availabe. The connection, configuration and use
        of these modules are completely analogous to the non-hemispheric sensor
        modules. The correction-specific software functions, such as e.g. the
        setting of the installation type or the use of the corrected Display
        Mode, are identical to the functions in the new hemispheric Q71 camera
        model (see above).
    Support of the new Thermal Eco module
    This new low-cost thermal module can be integrated into all existing mounts
    and connected to an S74 camera (also to the sensor ports M1 and M2). The
    configuration and usage are analogous to the other thermal sensor modules.
    This module is particularly suitable for the use of the Activity
      Sensor and for use in Thermal Overlay images.
    In addition, Thermal Reference Events are supported, but
    temperature measurements and Spotmeter Events
    are not available.
    Multiview view
    The familiar Multiview
        view for displaying live images and the latest event images from one or
        more cameras in the web browser is now also available in the new
        graphical user interface. This view is activated via the new function
        icon  on the right side of the title bar. After activating this
        view, the function icon
 on the right side of the title bar. After activating this
        view, the function icon  for configuring the Multiview views appears. The actual
        configuration and use of the Multiview views do not differ from the
        Multiview views of the previous software versions.
  for configuring the Multiview views appears. The actual
        configuration and use of the Multiview views do not differ from the
        Multiview views of the previous software versions.
    LED Configuration
    The Admin Menu > Camera
          Administration > LED Setup dialog contains an
        additional section LED Order and
            Settings for the individual configuration of the
        camera LED and the LEDs of all sensor modules connected to the camera.
    Software Update
    The Admin Menu > System Update > Update System software dialog
    has been completely redesigned and improved. Among other things, the status
    messages issued during the system update are now displayed directly in the
    dialog. For compatibility reasons, the previous dialog can still be used by
    calling the link <IP>/admin/sysupload
    directly.
    App license management
    Using the
        new Admin Menu > Camera
          Administration > Manage App Licenses dialog,
        the required licenses for integrated Apps can now also be requested and
        activated directly from the camera. As in the MxManagementCenter, both
        offline and online activation is also possible here.
    
    Improvements to the new graphical user interface
    The following improvements have
        been implemented for the new graphical user interface for web browsers
        introduced with version 7.2.1.29:
    
      - Title bar
 The title bar
          is now not drawn transparently and thus all symbols contained in it
          are always clearly recognizable. In addition, the icon for
          deactivating/activating PTZ actions in the activated state is no
          longer crossed out.
In the Admin Menu > Page Administration > Language and Start
        Page dialog, there is a new section Shortcuts. There, one or two
      soft button functions can be defined, which can then be selected using
      additional icons on the right side of the title bar of the web browser
      window.
      
      - Visual Alarm ProfilesIn the Logos and
          Image Profiles
        section of the Admin Menu there is now an additional link Visual Alarm Profiles.
        This allows these profiles to be edited faster than before, for example
        to be used in SNMP Alarm Traps (see next section).
- Event Player
 The function icons in Event Player mode are now easier to recognize.
- Event overview
 In the Setup Menu >
              Event Control > Event Overview dialog,
            the active events are now easier to recognize.
- Camera Mode dialog
 The Admin Menu > Hardware Configuration > Camera Mode dialog
          has been improved so that it is no longer possible to trigger a camera
          reboot from the dialog without permanently saving the changes made
          beforehand.
- Configuration of the Certified Apps
 When using a Dark Theme, the bright areas
          of some dialogs for configuring Certified Apps (e.B. Vaxtor LPR) are
          now easier to read.
 
 
Enhanced SNMP Traps
    Alarm Traps
    Visual
        Alarms, which are linked to
        individual events via Action Groups, can now be used to generate SNMP Alarm Traps.  These
        are then sent to the SNMP client when one of the associated events is
        triggered. In addition, an SNMP trap can also be generated for
        acknowledging the visual alarms. 
    To configure
          such SNMP Traps, the following steps are necessary:
    
      - Configuring SNMP
- Creating a Profile  (e.g. "VA
          Permanent") for a Visual Alarm
            with the following properties
        - Name = VA Permanent
            (example)
- Display time = Unlimited
- Alarm Acknowledgement = Enabled
- Send SNMP Trap = Activated
- Create an Action Group with the following properties:
        - Name = VA Permanent
            (example)
- Action 1 = Visual Alarm: VA Permanent
- Event selection = <selection of the desired events,
            including "Signal: UC" for testing >
Subsequently, the triggering of SNMP Traps via a Visual Alarm and its acknowledgement can be tested as follows:
    
      - Activation and operation of the soft button "UC Event" (=
          factory setting)
- Activation and activation of a soft button "Acknowledge"
Alternative:
    
      - Activation and operation of a shortcut (see above) "UC
          Event" in the title bar
- Activation and operation of a shortcut (see above)
          "Acknowledge" in the title bar
Additional:
    
      - Show the variable $(EVT. VATIMESTAMP) in
          the live image to display the timestamp of the last acknowledgement of
          a Visual Alarm
- Signaling of the Visual Alarm via the camera LEDs (see
          above), e.g. selection Visual
            Alarm as a value for LED Main
            Switch
This
        creates the following SNMP trap
          OIDs:
       
          .1.3.6.1.4.1.21701.3.5.1
          --> visualAlarmNew
      .1.3.6.1.4.1.21701.3.5.2
          --> visualAlarmCleared
     Error
        Messages
      
    Certain
        camera error messages can now also be sent as SNMP Traps to a connected
        SNMP client. For this purpose, the following dialogs have been extended
        by an additional option SNMP
          Traps:
    
      - Admin Menu > System
            Information > Error Notification, each with an option in the Notification
          and Notification After Reboot sections
- Admin Menu >
            Storage > Storage Failure Detection, in the Notification section
- Admin Menu >
          Network Setup > Web Server, in the Intrusion
          Detection Settings section 
Extended text variables
    
      - New temperature
            variables with additional formats
 For a more flexible display in the live image and better use in camera
          API calls, new temperature variables have been added. In addition to
          the existing variables
 '$(SEN.<Sensor
            type>.Celsius)' and
            '$(SEN.<Sensor Type>.Fahrenheit)'
 it's now possible to use the new variables
 '$(SEN.<Sensor
            Type>.<Unit>.<Format>)'.
 The following applies:
    
      
        - Unit
            from {'Celsius',
              'C, 'c, 'Fahrenheit', 'F', 'f', 'Kelvin', 'K', 'k'}
- Format
            from {'INT',
              'I10', ''F10', 'F41', 'F72', 'NUM'} with the following
            meanings:
          - INT:
              Output as an integer with possibly negative sign
- I10:
              Output of the value multiplied by 10 as an integer with possibly
              negative sign
- F10:
              Output of the value as an integer with at least one place and with
              sign
- F41:
              Left-aligned output with at least 4 digits, with 1 decimal place
              and sign
- F72:
              Left-aligned output with at least 7 digits, with 2 decimal places
              and signs
- NUM:
              Output as a decimal number with decimal places with possibly
              negative sign - specially designed for use within JSON expressions
- Examples of a measured Thermal TR temperature value of +56.7 C°:
          - $(SEN.TTR.C.INT)
              => "56"
- $(SEN.TTR.C.I10)
              => "567"
- $(SEN.TTR.C.F41)
              => "+56.7"
- $(SEN.TTR.C.F72)
              => "+56.70 "
- $(SEN.TTR.C.NUM)
              => "56.7"
      - 'SKIP'option
            for text variables
 The '$(<Variable>,
            SKIP=<Number>)' option
          skips the first 
            <number> characters
          of the value of <Variable>
          in the output. For a negative <number> the
          characters of the variable value are skipped from the end.
- Temperature variables for different Thermal
            Measurement Windows 
 In addition to the variables $(SEN.TTR.CELSIUS/FAHRENHEIT)now
          also the variables $(SEN.TTR.0.
            CELSIUS/FAHRENHEIT), $(SEN. TTR.1.CELSIUS/FAHRENHEIT),...
            $(SEN.TTR.<(number of
              measurement windows)-1>.CELSIUS/FAHRENHEIT) are
          available to determine the specific temperature values in the
          individual Measurement Windows 0,...
            <(number of measurement windows)-1>.
Updated and new Certified Apps
    Along with this version of the
        camera software, a new Certified App package
        'MX_preinstalled_apps_2021-12-14.app' has also been released. This
        package contains all Certified Apps, including the
        MOBOTIX
          Analytics app with AI/Deep Learning-based object recognition.
        Compared to the previous version, it also
        includes
          revised versions of the Apps from A.I. Tech, FFGroup and Vaxtor,
        as well as two new Apps from Vaxtor for
        the recognition of aircraft identification numbers and license plates, a
        new
          App from  FFGroup  for
        license plate recognition and a new App from Irisity
        for the detection of burglaries.
        Details on the exact content of the package and the changes can be found
        in the release notes for the package in the section Support
          > Download Center > All Software Downloads > Certified Apps
          > MX Certified Apps Release 2021-12-14
         of the MOBOTIX website
        (https://www.mobotix.com).
    Other improvements
    
      - Camera Support Information
 Downloading the support information using the Admin Menu > System
        Information > Download Support Information dialog now generates a
        file in the format '.tgz'
        instead of '.eml'
        as before.
Bugfixes
    
      - Image flickering at
            WDR
 When WDR was activated, minor changes in illumination could lead to a
          change in the internal exposure parameters, which was noticeable in
          the form of a single image frame that was too bright as a short
          flare-up.
- Problems with the
            classic design 
 When the camera start
            page was
          displayed in the Historical Layout, the event list was not filled in the
            Event Player view.  In addition, in this setting,
          no detection
            areas could be created in the live image for some Certified Apps (e.g. FFLPR MMC).
- Thermal events after
            camera restart
 Thermal sensors could cause thermal events configured after a camera
          restart to be triggered incorrectly.
- Variables 
              $(ID.ET0)/$(ID.FIP)
 When the variables $(ID.ET0)
            and $(ID.FIP)
          were used together in this order, the current camera IP address was
          returned twice instead of the current IP address and factory IP
          address.
- Microphone and
            Speakers dialog
 The description text for the Option Announce network data in the Admin Menu > Audio and VoIP Telephony
            > Speaker and Microphone dialog of
          an M73 camera contained an error (using the "R button").
- Window definitions in
            dual image
 When using the camera selection Both (dual image), no windows
          could be defined for the left image sensor in the functional areas Activity Sensor, Video Motion
            Detector (VM) and
          Exposure.
- Exposure window in the
            Quick Controls
 After defining an exposure window using the Quick Controls, an empty
          white window was sometimes displayed.
- Image settings
 The changes to settings in the Setup Menu > Image Control
            > General Image Settings
        dialog were then not displayed correctly in the
          corresponding fields of the  Quick
            Controls. This
          has been corrected, but a reload of the browser window is still
          necessary for the correct display in the Quick Controls.
- Admin and Setup Menu
 When the Admin Menu
          and Setup Menu dialogs were reopened, previously
          collapsed or collapsed areas were not displayed correctly opened or
          closed according to the last status.
- PI event
 In the Setup Menu > Event Control
            > Event Overview dialog, a PI event
          was entered in the Environment Events
          section, even if no MultiSense
          module with PIR sensor was connected.
- Format Storage Medium
            dialog
 The Format Storage Medium dialog, which can be used in the Event
            Player view when
          downloading events, contained the invalid RAM Buffer
            selection option.
Known Limitations
    
      - Microphone Event
 Currently, no microphone event is supported. This applies to the
        built-in microphone in the Audio and MultiSense module as well as to a
        connected microphone, to the Line-In connector of the S74 Audio IO board
        and to the new Q71 model.
- Dialog Integration Protocols
 For M73 cameras with only one sensor module, the Admin ->
          Camera Administration -> Integration Protocols dialog is
        empty after activating one of the protocols ONVIF
        or Genetec via the
        installation wizard of the web browser. This state can be corrected by
        first deactivating the set protocol ONVIF or Genetec
        and then turning it back on.
 
     
     
     
     
     
     
     
    
    top
     
    Software Release MX-V7.2.1.29 − for M7 Camera Models M73, S74
    Creation Date: 2021-08-20
    Publishing Date: 2021-08-31
    
      Important notes on installation
      
        - With this version, no different packages are needed for M73
            and S74 cameras. Both camera models are updated with the
          same file MX_system_7_2129.mpl 
          from the section Support > Download Center > All
            software downloads > Cameras > MX system release 7.2.1.29
          of the MOBOTIX website (https://www.mobotix.com).    
- If you are using Certified Apps in the camera, you must update them
          using the MX_preinstalled_apps_2021-08-20.app
          package from the Support >  Download Center > All
            Software Downloads > Certified Apps section of the
          MOBOTIX website (https://www.mobotix.com). This
          package also includes the App MOBOTIX Analytics with AI/deep
            learning-based object recognition.
 
    
    Enhancements and improvements
    Uniform software for different camera models and apps (camera mode)
    The installation file of this software version can be used for updating
      M73 and S74 models alike. It also directly supports the use of the App MOBOTIX
        Analytics with AI/deep learning-based object recognition. After
      installing this App (see below), only the option Camera Mode
      in the new Admin > Hardware Configuration > Camera mode
      dialog has to be changed from Streaming to AI . After
      a subsequent camera reboot the App can then be activated
      and via the Setup > Control for Certified Apps > Settings
        for Certified Apps dialog.
    
      Note:
      When operating the camera in AI mode, the following restrictions apply:
      
        - Only one optical image sensor can be connected and
          used. However, the additional use of a Thermal Sensor module
            is possible. This requires a Thermal Sensor module of the
          latest generation (with a "B" in the order number, e.B.
          "Mx-O-M73TB-640R050"), which must then be connected to port M2. In
          this case, e.g. the configuration as a day/night camera (Camera
            Selection Auto) together with an AI/deep
          learning-based Object Recognition for the optical sensor and a use of
          the Activity Sensor for the Thermal Sensor module represents a useful
          application.
- The WIDE Dynamic Range (WDR) function is not available.
 
    New graphical user interface for web browsers
    The layout and operation of the HTML pages for controlling the camera
      using a web browser have been fundamentally revised and improved. The
        structure of the dialogues and their context have not been changed!
      The following describes the most important changes compared to the
      previous versions.
    Camera Start Page
    
    
      - In addition to the live camera image, the start page now contains only
        a partially transparent title line with the following elements::
      
        - Menu selection at top left  : This opens a dialog for selecting all Quick Controls and
          all Soft Buttons, including Admin Menu and Setup
            Menu : This opens a dialog for selecting all Quick Controls and
          all Soft Buttons, including Admin Menu and Setup
            Menu
Function symbols in the right corner of the
      title line:
    
      
        - PTZ actions  : With this symbol, PTZ (Pan-Tilt-Zoom) actions can be
          (de-)activated with the mouse in the live image. : With this symbol, PTZ (Pan-Tilt-Zoom) actions can be
          (de-)activated with the mouse in the live image.
- Pause live image  : This allows the live display of the camera image to be
          paused in the browser, for example to reduce computer usage, or to
          capture a detail in the current camera image. : This allows the live display of the camera image to be
          paused in the browser, for example to reduce computer usage, or to
          capture a detail in the current camera image.
- Save image  : This feature saves the current live camera image. : This feature saves the current live camera image.
- Camera online help  : This opens the HTML online help of the camera. : This opens the HTML online help of the camera.
- Camera status  : Clicking on this icon opens the Camera Status
          dialog. : Clicking on this icon opens the Camera Status
          dialog.
- Player view  : Here you can switch between the Live and Player View. : Here you can switch between the Live and Player View.
The design of the start page can be adjusted
      in the new Page Design area of the Admin >
        Page Administration > Language and Start Page dialog. 
      There, the following new options are available:
    
      - Theme: to switch between a dark and light background
- Layout: to switch between the new and classic layout
        of the start page
- Window Opacity: to change the transparency of the
        individual dialogs 
The camera image is now
      always scaled so that it is completely visible in the browser window. This
      applies both to the live image and to the display in the camera player.
    
    After displaying the Soft-Buttons by opening
      the menu in the upper left corner of the start page, the edit mode for the
      Soft-Bbuttons can be opened via the lock symbol in the lower left corner.
      The positions of the individual Soft-Buttons can now be changed by drag
      & drop with the mouse. In addition, by pressing the symbol  

 at the bottom left, a list of the defined Soft-Buttons 
      is displayed, from which a Soft-Button can be inserted by drag
      & drop with the mouse into the Soft-Buttons list of the start page.
Structure and operation of the dialogues
    
      - Window areas
 The window areas of the individual dialogs are now all limited to the
          display area of the camera window in the web browser.
- Parameter areas
 The individual parameter areas for grouping certain options within the
          dialogs are folded in by default and can be opened and closed again
          via the Symbol in the right
          corner of the area title line. The camera SW uses browser cookies to
          remember the state of the dialogs and restores it after closing and
          reopening a dialog. in the right
          corner of the area title line. The camera SW uses browser cookies to
          remember the state of the dialogs and restores it after closing and
          reopening a dialog.
- Graphical definition of windows in the camera image
 At all points for the definition of window areas within the camera
          live image (e.g. when defining exposure windows) there is now no need
          to use a key combination ("Shift + Click", "Click"). 
            Instead, after pressing the respective button for adding an
          area (e.g. the Add
          Exposure Area
          button in the Setup > Image Settings > Exposure
              Settings) dialog,
          the windows can be mounted
          directly with the mouse. All stretches of the rectangle defined by
          this contain "active centers", which can be moved with the mouse and
          thus used to define polygons.
Editing the
          camera configuration (only for experts!)
    
      - Using the Admin
            > Configuration > Edit menu entry,
          the new Kurator
          dialog is now opened, with the
          JSON-based view of the camera configuration for reading and modifying
          configuration entries.
- Via the menu entry Admin > Configuration > Text Edit,
        the Edit Configuration File dialog can still be
        opened, with the classic file view, grouped by "Sections", for reading
        and changing the camera configuration.
Online Help
    The online help has been adapted to the changed user interface and in
      individual dialogs additional additions and changes have been made.
    MOBOTIX HUB connection with failover recording on the SD card
    When integrating the camera
      into the MOBOTIX HUB, the so-called "Failover Edge Recording"
      is now supported: For this purpose, the camera permanently monitors the
      RTSP streaming through a previously defined recording service as the
      camera's streaming client. If the streaming stops for a previously defined
      period of time, e.g. due to a failure of the recording service, the video
      and audio data are automatically recorded on the camera's internal SD card
      until the streaming connection to the streaming client (= recording
      service) has been restored. 
    Depending on the settings of
        the failover recording in the Management Client of MOBOTIX HUB, the data
        between the SD card and the recording data of the recording service, is
        then, either manually or automatically, synchronized by the
        recording service. In both cases, the data stored on the SD card during
        the failure is read by the camera and transferred to the server
        database.
    The activation and configuration of this failover mechanism is
      carried out in the Admin > Camera Administration > Integration
        Protocols dialog. After selecting the Protocol ONVIF or
      Genetec + ONVIF, the new area
      Edge Recording appears in the dialog. 
        There, the failover recording is activated and the necessary
      settings, e.g. such as the IP address of the RTSP client and the waiting
      time (minimum duration of the failure) are defined.
    
    
      Note:
      
      
        -  In the present software version, the recordings are stored
            by the Failover Edge Recording on the camera-internal SD
          card in the same area as the data from activated Apps, i.e. in the User
            Data partition. This will be changed in a subsequent
          software version and the size of the area on the SD card available for
          Failover Edge Recording will be adjustable.
- Users of the previous beta release V7.2.0.11 must reformat
            the SD card, then reconfigure and save
          the Failover Edge Recording settings in the
          Integration Protocols dialog.
 
    Support of thermal sensor modules together with audio modules
    The thermal sensor modules of the latest generation (with a "B" in the order
    number, e.B. "Mx-O-M73TB-640R050") can also be connected to port M1 or M2
    with this firmware version in the camera and thus used together with an
    audio module, which must be connected to port M3. For this purpose,
    the  Admin > Hardware Configuration > Sensor Module
      Configuration dialog has been changed so that thermal sensor
    modules can also be selected for ports M1 and M2. This applies to both M73
    and S74 camera models.
    Improvements in the area of Certified Apps
    Unified installation package
    Along with this version of the camera software, a new Certified App
      package 'MX_preinstalled_apps_2021-05-27.app' has also been released. This
      package now includes all Certified Apps, including the
      App MOBOTIX Analytics with AI/deep learning-based object
        recognition. Compared to the previous version, it also includes
      revised versions of the Apps from A.I. Tech., FFGroup, Vaxtor and Visage
      Technologies, as well as new Apps from Vaxtor for identifying railway
      wagons with UIC codes and from FFGroup for identifying vehicle
      characteristics (MMC). For details on the exact content of the package and
      the changes, see the release notes for this package in the Certified
        Apps > MX Certified Apps Release 2021-05-28 section of the
      MOBOTIX Beta website (https://www.mobotix.com/de/beta).
    New functions in the Settings dialog for Certified Apps
     
    In the Setup
          > Certified App Control > Certified App Settings dialog,
        the following extensions have been integrated:
    
      - Resource monitor
 With this new option, the current utilization of the camera resources
        can be displayed in the live image. Selecting the option displays the
        current values for the maximum frame rate, memory used, CPU usage, and
        even active Apps. This allows the camera load to be monitored,
        especially in the case of several activated Apps. If necessary, an
        overload, which may lead to a camera restart, can be avoided then by the
        targeted deactivation of individual Apps.
 
- Custom text fonts
 With the help of the new Custom
            font option and the new Manage Font File
          dialog, which is opened via the Manage Font File
          link in the above dialog, you
          can load your own text fonts into the camera and select them for the
          display of app-specific texts in the live image. This allows, for
          example, identified license plates with Arabic characters to be
          displayed correctly in the image.
      - Deleting Apps
 Using the Delete application button behind
          each App, the App in question, including
          the data generated by it, can be deleted  from
          the camera.
 
    WDR-Funktion
    The Wide Dynamic Range function for handling large
      differences in brightness in the image has been further significantly
      improved compared to the previous version using a different calculation
      method. In particular, dark areas of the image are now displayed better
      and there is less color distortion than before. The WDR function is still
      activated using the  Wide Dynamic Range option in
      the Setup > Image Control > Exposure Settings
      dialog whereby only a distinction is made between the values On
      and Off. If required, the previous WDR algorithm with its 4
      setting options (Default,  Moderate, Strong and Aggressive)
      can also be activated for special application situations by selecting the
      value On(Legacy).
    
    
      Note:
      
      After a 
software update to the present version, WDR is always
        deactivated, even if it was switched on in a previous version
      7.1.3.19 or lower.
 
    Other improvements
    
      - IR light module
            together with LPF module
 By activating an LPF sensor module, an IR light module also connected to
        the camera is now automatically switched on at all times.
Bugfixes
    
      - RTSP-Streaming
 If only one image sensor module was connected to a M73 or S74 camera,
        the streaming mode Raw could not be selected.
- Setting the image quality with ONVIF integration 
 During an ONVIF integration of the camera, the information
        about the current setting of a constant bit rate (value of parameter RateControl.ConstantBitrate)
        was in some cases not properly returned to the ONVIF client. In
        addition, the ONVIF setting of a constant bitrate (by the same
        parameter) for streams with video codec setting H.265 was
        incorrect.
- Secure SD card formatting
 Formatting the camera's internal SD card using the Secure Deletion
        mode could lead to a termination of the function and subsequent restart
        of the camera.
- Camera restarts when using Apps
 If several apps were activated in the camera at the same time,
        the camera could restart.
Known Limitations
    
      - Microphone Event
 Currently, no microphone event is supported. This applies to the
        built-in microphone in the Audio and MultiSense module as well as to a
        connected microphone and the Line-In connector of the S74 Audio IO
        board.
- Dialog Integration Protocols
 For M73 cameras with only one sensor module, the Admin ->
          Camera Administration -> Integration Protocols dialog is
        empty after activating one of the protocols ONVIF
        or Genetec via the
        installation wizard of the web browser. This state can be corrected by
        first deactivating the set protocol ONVIF or Genetec
        and then turning it back on.
 
     
     
     
     
     
    
    top
     
    Software Release MX-V7.1.3.19 − for M7 Camera Models M73, S74
    Creation Date: 2021-03-17
    Publishing Date: 2021-03-31
    
      Important notes on installation
      
        - If you are using Certified Apps in the camera, you
          must first update them using the MX_preinstalled_apps_2021-03-17.app
          package from the Support > Download Center > Software Downloads
          > Certified Apps > MX Certified Apps Release 2021-03-17
          directory of the MOBOTIX website www.mobotix.com. You can then update
          the camera firmware.  
- The firmware for M73 and S74 cameras is provided
          in different packages. Therefore, in addition to the
          files MX_system_7_1319.mpl/zip
          for M73 cameras, you can also find files MX_system_S74_7_1319.mpl/zip 
          with the current firmware for S74 cameras in the Support > Download
          Center > Software Downloads > Cameras > MX System Release
          7.1.3.19 directory of the MOBOTIX website www.mobotix.com.
- The packages to support MOBOTIX Analytics with AI/Deep
            Learning-based object detection also vary for M73
            and S74 cameras. Therefore, the files  MX_system_M73_ObjectDetectionYv3_7_1319.mpl for M73 cameras and MX_system_S74_ObjectDetectionYv3_7_1319.mpl for S74 cameras are
          now available in the above directory.
- After installing the package to support MOBOTIX Analytics
            with AI/Deep-Learning-based object recognition (see above),
          no WDR (Wide Dynamic Range) function is available on
          the camera.
 
    
    Improved and additional Certified Apps
    This release has improved and partially expanded existing Certified Apps
      and added new apps.
    Vaxtor ALPR MMC LPR V1.2.1(*new*)
    With this new App, the brand, model, color and class of vehicles can be
    recognized in addition to the license plate. It offers the following
    functions:
    
      - Detection of single- and two-line flags
- Identification of signs with Latin, Arabic and Hebrew characters.
As with the other Apps, the connection to the event logic and alarm
    functions of the camera is done using messages from the MxMessage System. In
    addition, the detection results can be viewed and evaluated using Smart Data
    Sources in the MxManagementCenter (MxMC, version 2.4.4 onwards).
    
    Vaxtor Containers V1.2.1 (updated)
    With this new version of the App for the detection of transport container
      codes according to ISO 6346, the analysis can now also be done on a live
      camera dual image.
    Vaxtor LPR V1.1.2 und ADR V1.1.2 (updated)
    The new versions of these two Apps correct problems when using multiple
    detection ranges.
    Visage Technologies Facial Recognition V1.2 (already contained in
      App-Package 2021-02-24) 
    Firmware 7.1.3.19 now also supports this version of the app, in which
      some bugs have been fixed and performance improved. In addition, facial
      recognition now works much more robustly in demanding conditions such as
      large scaling variability, difficult lighting, certain poses and covers
      such as beards, glasses and  masks. In firmware
      version 7.1.3.15, this App version could not be used yet.
    Improvements
    
      - Section Apps in Camera Status
 In the Camera Status dialog, there is a new
        Apps section.  There, the version of the loaded
        App package as well as the maximum SD card storage for Apps and the
        storage currently occupied by Apps are displayed.
 
 
Bugfixes
    
      - MultiSense temperature with negative values
 When using a MultiSense module to determine the ambient temperature,
        negative values below 0°C were displayed in the variable $(SEN.
          TCx.CELSIUS)only as
        0°.
 
- Acticity-Sensor Events in Thermal Cameras
 Using self-defined detection ranges for the Activity Sensor
        could cause the triggering event to be displayed in the image in the
        wrong position.
- ONVIF -Integration
 An ONVIF integration of the camera could cause problems in certain VMS
        applications (e.g. Avigilon ACC) due to an error in the requested H.265
        profile.
Known Limitations
    
      - Microphone Event
 Currently, no microphone event is supported. This applies to the
        built-in microphone in the Audio and MultiSense module as well as to a
        connected microphone and the Line-In connector of the S74 Audio IO
        board.
- Dialog Integration Protocols
 For M73 cameras with only one sensor module, the Admin ->
          Camera Administration -> Integration Protocols dialog is
        empty after activating one of the protocols ONVIF
        or Genetec via the
        installation wizard of the web browser. This state can be corrected by
        first deactivating the set protocol ONVIF or Genetec
        and then turning it back on.
- RTSP-Streaming
 If only one image sensor module is connected in the M73, the streaming
        mode  Raw cannot be selected at this time.
 
     
     
     
     
    
    top
     
    Software Release MX-V7.1.3.15 − for M7 Camera Models M73, S74
    Creation Date: 2021-01-26
    Publishing Date: 2021-01-28
    
      Important notes on installation
      
        - If you are using Certified Apps in the camera, you
          must first update them using the MX_preinstalled_apps_7_1315.app
          package from the Support > Download Center > Software Downloads
          > Certified Apps > MX Certified Apps Release 7.1.3.15 directory
          of the MOBOTIX website www.mobotix.com. You can then update the camera
          firmware.  
- The firmware for M73 and S74 cameras is provided
          in different packages. Therefore, in addition to the
          files MX_system_7_1315.mpl/zip
          for M73 cameras, you can also find files MX_system_S74_7_1315.mpl/zip 
          with the current firmware for S74 cameras in the Support > Download
          Center > Software Downloads > Cameras > MX System Release
          7.1.3.15  directory of the MOBOTIX website www.mobotix.com.
- The packages to support MOBOTIX Analytics with AI/Deep
            Learning-based object detection also vary for M73
            and S74 cameras. Therefore, the files  MX_system_M73_ObjectDetectionYv3_7_1315.mpl for M73 cameras and MX_system_S74_ObjectDetectionYv3_7_1315.mpl for S74 cameras are
          now available in the above directory.
- After installing the package to support MOBOTIX Analytics
            with AI/Deep-Learning-based object recognition (see above),
          no WDR (Wide Dynamic Range) function is available on
          the camera.
 
    
    Improved and additional Certified Apps
    This release has improved and partially expanded existing Certified Apps
      and added new apps.
    FF Group V1.2
    
      - With this version of the App, license plate recognition is
          also possible when the camera creates a dual live image.
- In addition, the list of supported countries has been
          extended to include South Africa, Taiwan, Vietnam, Indonesia and Hong
          Kong
 
Vaxtor ADR V1.1.1
    In addition to license plates, this new App also allows to identify signs
    for dangerous goods in accordance with the "European
      Agreement Concerning the International Carriage of Dangerous Goods by Road
      Vol. 1 (ADR)". To detect ADR characters, in the configuration of
    the App the value ADR (= last list entry) has to be selected as Country.
    Vaxtor LPR V1.1.1 
    With this new version of the App for the recognition of license plates,
      the following improvements have been implemented:
    
      - Improved identification of license plates with Arabic letters.
- Enlarged database for the detection of German city and
          district codes. Previously, some license plates (e.B RA, BH,
        KA,...) could not be identified and did not trigger an event.
Known Limitations
    
      - Microphone Event
 Currently, no microphone event is supported. This applies to the
        built-in microphone in the Audio and MultiSense module as well as to a
        connected microphone and the Line-In connector of the S74 Audio IO
        board.
- Dialog Integration Protocols
 For M73 cameras with only one sensor module, the Admin ->
          Camera Administration -> Integration Protocols dialog is
        empty after activating one of the protocols ONVIF
        or Genetec via the
        installation wizard of the web browser. This state can be corrected by
        first deactivating the set protocol ONVIF or Genetec
        and then turning it back on.
- RTSP-Streaming
 If only one image sensor module is connected in the M73, the streaming
        mode  Raw cannot be selected at this time.
 
     
     
     
    
    top
     
    Software Release MX-V7.1.3.11 − for M7 Camera Models M73, S74
    Creation Date: 2020-12-11
    Publishing Date: 2020-12-16
    
      Important notes on installation
      
        - If you are using Certified Apps in the camera, you
          must first update them using the MX_preinstalled_apps_7_1311.app
          package from the Support > Download Center > Software Downloads
          > Certified Apps > MX Certified Apps Release 7.1.3.11 directory
          of the MOBOTIX website www.mobotix.com. You can then update the camera
          firmware.  
- The firmware for M73 and S74 cameras is provided
          in different packages. Therefore, in addition to the
          files MX_system_7_1311.mpl/zip
          for M73 cameras, you can also find files MX_system_S74_7_1311.mpl/zip 
          with the current firmware for S74 cameras in the Support > Download
          Center > Software Downloads > Cameras > MX System Release
          7.1.3.11 directory of the MOBOTIX website www.mobotix.com.
- The packages to support MOBOTIX Analytics with AI/Deep
            Learning-based object detection also vary for M73
            and S74 cameras. Therefore, the files  MX_system_M73_ObjectDetectionYv3_7_1311.mpl for M73 cameras and MX_system_S74_ObjectDetectionYv3_7_1311.mpl for S74 cameras are
          now available in the above directory.
- After installing the package to support MOBOTIX Analytics
            with AI/Deep-Learning-based object recognition (see above),
          no WDR (Wide Dynamic Range) function is available on
          the camera.
 
    Improvements
    
      - WDR (Wide Dynamic Range) function with test option
 After activating the WDR function in the Setup > Image
          Control > Exposure Settings dialog, a further improvement
        of the image quality in difficult lighting situations can be achieved,
        there using the new Experimental Exposure Settings
        option.  In particular, over-exposures can be avoided after rapid
        changes in brightness in a small area of the image.
 
    
    
      - Access data for file servers
 The password of a file server defined for storage in the Admin
          > Storage > Storage on External File Server / Flash Device
        dialog can now also contain the special character '#'.
Bugfixes
    
      - Switching signal output after S74 camera restart
 For S74 cameras a configured signal output was switched on for a short
        while (< 1s) after a camera reboot.
 
- Dual Image in the
            MxManagementCenter (MxMC)
 When
          displaying a camera dual image in the preview mode of the MxMC (e.g.
          in the view Research or in
          the dialog Clip and Recording Configuration)
          the left and right camera images were swapped.
- Image Programs
 The selection of an Image Program in the quick controls of the camera
          live view in the web browser resulted in an error message and the
          corresponding settings were not applied.
- Signal output for
            firmware with AI/deep learning-based object detection
 When using the firmware to support MOBOTIX Analytics with AI/Deep
            Learning-based object detection,  the
          signal output switch of a M73 camera was without function.
      - Thermal and WDR
 In the Setup > Image Control > Exposure Settings
        dialog, WDR could also be activated for a thermal sensor and switching
        on this option had no effect. The WDR function has been removed in this
        case.
 
Known Limitations
    
      - Microphone Event
 Currently, no microphone event is supported. This applies to the
        built-in microphone in the Audio and MultiSense module as well as to a
        connected microphone and the Line-In connector of the S74 Audio IO
        board.
- Dialog Integration Protocols
 For M73 cameras with only one sensor module, the Admin ->
          Camera Administration -> Integration Protocols dialog is
        empty after activating one of the protocols ONVIF
        or Genetec via the
        installation wizard of the web browser. This state can be corrected by
        first deactivating the set protocol ONVIF or Genetec
        and then turning it back on.
- RTSP-Streaming
 If only one image sensor module is connected in the M73, the streaming
        mode  Raw cannot be selected at this time.
 
     
     
    
    top
     
    Software Release MX-V7.1.2.24 − for M7 Camera Models M73, S74
    Creation Date: 2020-10-26
    Publishing Date: 2020-10-27
    
      Important notes on installation
      
        - If you are using Certified Apps in the camera, you
          must first update them using the MX_preinstalled_apps_7_1224.app
          package from the Support > Download Center > Software Downloads
          > Certified Apps > MX Certified Apps Release 7.1.2.24 directory
          of the MOBOTIX website www.mobotix.com. You can then update the camera
          firmware.  
- The firmware for M73 and S74 cameras is provided
          in different packages. Therefore, in addition to the
          files MX_system_7_1224.mpl/zip
          for M73 cameras, you can also find files MX_system_S74_7_1224.mpl/zip 
          with the current firmware for S74 cameras in the Support > Download
          Center > Software Downloads > Cameras > MX System Release
          7.1.2.24  directory of the MOBOTIX website www.mobotix.com.
- The packages to support MOBOTIX Analytics with AI/Deep
            Learning-based object detection also vary for M73
            and S74 cameras. Therefore, the files  MX_system_M73_ObjectDetectionYv3_7_1224.mpl for M73 cameras and MX_system_S74_ObjectDetectionYv3_7_1224.mpl for S74 cameras are
          now available in the above directory.
- After installing the package to support MOBOTIX Analytics
            with AI/Deep-Learning-based object recognition (see above),
          no WDR (Wide Dynamic Range) function is available on
          the camera.
 
    Enhancements and Improvements
    Support of Camera Model S74 and other Function Modules
    This version supports the new MOBOTIX 7 camera model S74. It is a robust
      camera with a die-cast aluminum housing, specially designed for concealed
      installation, offering connectivity for up to four different image sensor
      and function modules. Just like the M73 camera, the S74 can alternatively
      be operated with one or two optical image sensor modules, with a Thermal
      (-TR) sensor module alone, or with a Thermal(-TR) sensor module together
      with an optical image sensor module. In addition, up to two IR-Light
      modules and/or other new function modules (see next section) can be
      combined with the image sensors. Cables with a length of 1, 2, or 3 meters
      are available for connecting the image sensor and function modules.
    Notes on the configuration of the S74:
      
      
        - In principle, the installation of an S74 camera is
          completely analogous to the setup of a M73 camera.
- Optical image sensors must be connected to
          connection ports M1 or M2. Thermal
          sensor modules must be connected to the M3 port.  
- When using a 3m cable to connect an image sensor
          module, it is mandatory to select the cable length Long (> 2
          meters) in the Admin > Hardware Configuration > Sensor
            Module Configuration dialog for this image sensor.
          Selecting this cable length reduces the maximum frame rate of an
          optical image sensor to 15 frames/s when WDR is activated (see below)
          for it.
- If the image sensor modules are installed using special mounts 
          (dual or surround mounts), this can also be set in the above dialog.
 
    In addition, the following new function modules for M73 and S74 camera
      models can be used with this firmware.
    MultiSense Module (M73 und S74)
    This function module for M73 and S74 cameras each features a light,
      temperature and passive infrared sensor and an integrated microphone. Just
      like the IR Light module, it can be connected to any of the 4 ports M1 to
      M4. The sensors are used to define events as usual in the Setup
        > Event Control > Event Overview > Environment Events
      dialog. After connecting several MultiSense modules to an S74, when
      configuring an ambient sensor the relevant connection port of the
      MultiSense module belonging to the sensor can be selected as the Sensor
        Source.
    
      Note
      The integrated microphone can only be used when connecting the MultiSense
      module to cable no. 3 of an M73.
    
 
    Audio Module (M73)
    With this new function module, M73 cameras have the usual audio
      functions, such as audio output and audio in the video recordings. After
      connecting the module, the audio is set up as usual in the Admin
        > Audio and VoIP Telephony > Microphone and Speaker
      dialog.
    Audio/IO-Board (S74)
    This allows an S74 camera to be extended with audio as well as switching
      input and output functions. 
    For the audio output, either the connector can be used to connect a
      (passive) speaker, or the line-out port can be connected to the line-in
      port of an audio amplifier. As an audio input, a microphone can be
      connected directly, or the line-in port can be connected to the line-out
      port of an audio output device (e.g. PC or smartphone). The desired audio
      functions are also configured after installing the board in the camera in
      the Admin > Audio and VoIP Telephony > Microphone and
        Speaker dialog.
    In addition, an input signal and a potential-free output switch (relay
      function) can be used with this board to control external devices. After
      installation of the board, input and output signals can be used as usual
      to define a signal event or signal output profile.
    New WDR Function
    By implementing a completely new algorithm, compared to the previous
      version, the behavior of the Wide Dynamic Range function
      for handling large differences in the image's brightness has been further
      significantly improved. The WDR function can be activated in the Setup
        > Image Control > Exposure Settings dialog. When WDR is
      activated, the settings that are not needed, such as Exposure
        Windows and Target Brightness, are
      automatically hidden. To adapt to the current scene, 4 different Contrast
        Enhancement Levels are available:  Default, Moderate,
        Strong and Aggressive. The default setting when
      activating WDR is Default and the further the value is changed
      in the direction of Aggressive, the more details can be seen
      even with large brightness differences. This is associated with an
      increasing change in the color characteristics in the image.
    4MP-Ultra-Low-Light-Sensor
    An additional, extremely light-sensitive image sensor with a resolution of 4
    megapixels can now be used for special application situations. This sensor
    is available as an IR Cut Day & Night sensor module with different lens
    variants and can be used with both M73 and S74 cameras. Its configuration is
    very similar to the setup of a 4K image sensor module.
    
    Functional Improvements and Enhancements from the Mx6 Camera Series
    In addition to the new features described above, this version also includes
    all extensions that have already been released with version 5.4.0.44 for the
    Mx6 camera line. These are extensions in the following areas:
    
      - Cyber Security and Network
- Storage
- Transfer Profiles
A more detailed description of these features can be found in the release
      notes of version 5.4.0.44.
    Other Improvements
    
      - ONVIF Enhancements
 When integrating the camera into other systems via ONVIF interface, an
        audio back channel is now also supported.
- Certified Apps 
 With this version, the existing Certified Apps have been revised and
        improved. Regarding the installation and configuration of the Apps,
        nothing has changed compared to the previous version 7.0.6.18. All Apps
        are now listed in the Setup > Certified
          App Control > Certified App Settings dialog with a
        specific version number..
- Online Help
 The integrated online help of the camera has been revised and
          supplemented in several areas, especially in the areas of thermal
          functions, MOBOTIX Analytics with AI-based object detection and the
          A.I. Tech Apps.
Bugfixes
    
      - Thermal TR events with Temperature Range
 The use of a temperature range instead of a threshold value to
        trigger thermal TR events was incorrect.
- MOBOTIX Analytics
 Using more than one counting corridor could produce incorrect
        counting values.
- Day-night switching for IR-Cut Day & Night Sensor Modules
 Switching between the day and night mode of these sensor
        modules could lead to misconduct if the lighting conditions changed
        shortly after a day-night switch or if a change in image settings was
        made.
- Color saturation
 The color saturation setting had no effect on the camera image.
Known Limitations
    
      - Switching output after S74 camera restart
 For S74 cameras a configured signal output is switched on for a short
        while (< 1s) after a camera reboot.
- Microphone Event
 Currently, no microphone event is supported. This applies to the
        built-in microphone in the Audio and MultiSense module as well as to a
        connected microphone and the Line-In connector of the S74 Audio IO
        board.
- Thermal and WDR
 In the Setup > Image Control > Exposure Settings
        dialog, WDR can also be activated for a thermal sensor and switching on
        this option has no effect.
 
- Dialog Integration Protocols
 For M73 cameras with only one sensor module, the Admin ->
          Camera Administration -> Integration Protocols dialog is
        empty after activating one of the protocols ONVIF
        or Genetec via the
        installation wizard of the web browser. This state can be corrected by
        first deactivating the set protocol ONVIF or Genetec
        and then turning it back on.
- RTSP-Streaming
 If only one image sensor module is connected in the M73, the streaming
        mode  Raw cannot be selected at this time.
 
     
    
    top
     
    Software Release MX-V7.0.6.18 − for M7 Camera Model M73
    Creation Date: 2020-09-15
    Publishing Date: 2020-09-18
    Enhancements and Improvements
    Improved and additional Certified Apps
    This release has improved and partially expanded existing Certified Apps
      and added new apps
    Notes on installing the Certified Apps:
      
      
        - To install all revised and new apps, after updating the firmware to
          version 7.0.6.18, the package 'MX_preinstalled_apps_7_0618.app' must
          be loaded into the camera , e.g. via the web browser dialog Admin
            > System Update > Update System Software. This
          package can be found on  www.mobotix.com  in the  Support
            > Download Center > Software Downloads > Certified Apps
            > MX Certified Apps Release 7.0.6.18 area.
- This update installs the latest versions of the apps of A.I. Tech.,
          Visage Technologies, MOBOTIX Analytics, FF Group and Vaxtor into the
          camera.
 
    
    MOBOTIX Analytics
    Analytics without additional function
        This version makes the MxAnalytics functions, known from previous camera
        lines, available for the first time within a pre-installed royalty-free
        App. As with all other Apps, activation and configuration is done via
        the Setup >
          Certified App Control > Certified App Settings dialog.
     
    Analytics with object recognition 
        In addition, the new Use AI component option enables
        object recognition based on AI/Deep Learning techniques. For example,
        you can distinguish between different types of objects, such as cars,
        trucks, people, etc. To use this feature, a special software package
        must be installed on the camera (see following note). After installing
        this package, the  Use
          AI component option and the additional Object Recognition Settings  app
        are available to configure AI-based object detection.
    
      Notes on installing the MOBOTIX Analytics
        app with object recognition:
      
        - To use the MOBOTIX Analytics app with AI/Deep-Learning-based object
            detection, the package 'MX_system_ObjectDetectionYv3_7_0618.mpl'
            must be installed on the camera instead of 'MX_system_7_0618.mpl' as
            firmware.
- ATTENTION: After installing this
            package, the camera always behaves like a single lense
            camera and uses the image sensor connected to M1 - this also applies
            to cameras with two installed image sensors.
- Using AI-based object detection together with other Apps
            is not recommended for performance reasons!
 
 
    A.I.Tech Apps
    All available A.I. Tech apps
        receive the following updates:
    
    
      - New 3rd Party VMS interfaces now allow the direct integration of A.I.
        Tech App Events into wavestore and Qognify Cayuga systems.
- Embedded Dashboard no longer needs to be activated separately, the
        interface is automatically activated after the App is started.
- The online documentation of the A.I. Tech Apps can now be accessed
        directly from the web interface.
Valid for all apps with 3D calibration
        (AI-Road3D, AI-Traffic, AI-Incident, AI-Crowd Deep):
      - In this release, a new 3D calibration mechanism has been introduced
        that allows you to get visual feedback about the procedure performed and
        to immediately detect errors made during the configuration procedure.
AI-Bio Deep:
      - A new facial recognition mechanism based entirely on deep learning is
        now available in the AI-BIO-DEEP App. This extension allows for greater
        accuracy in facial recognition and makes detection less susceptible to
        potential interference.
- In order to adapt the performance of the App to the needs of the
        customer, you can now choose between different neural networks for
        facial detection
AI-Spill:
    
      - The update adds a new deep learning-based neural network to the App to
        detect falling people, further improving the App's accuracy.
AI-Fire & AI-Smoke:
      - The App now includes an even more powerful yet more efficient
        classification mechanism that increases accuracy and detection speed.
Visage Technologies (VT) Face Recognition App
    
      - Faces can now be mapped to an "Granted" or "Denied" list while
        learning.
 
    
      Notes on updating the existing apps:
      
      
        - Configurations of the A.I. Tech Apps used should
          be backed up locally before the update, as they will be overwritten
          during the process. The configuration file can then be uploaded back
          to the new version of the App.
- Due to the new list structure, the already learned faces have to be
          re-learned after the update of the VT Face App.
 
    FF Group und Vaxtor LPR Apps
    
      - This means that two additional License Plate Recognition (LPR) Apps
        are now available.
General improvements
    
      - Errors when activating a Certified App, e.g. due to a faulty
        connection to the license server, are now logged in the system messages.
    
    Bugfixes
    
      - Setting the image sensor for thermal cameras
 For Thermal cameras the setting of the image sensor in the Admin >
        Hardware Configuration > Image Sensor Configuration dialog was
        incorrect in certain cases.
- MxActivity Sensor Events in Thermal Cameras
 Using MxActivity events with defined detection ranges could cause
        thermal cameras to fail when moving outside the defined areas.
- Thermal TR temperature at left image
 When using a Thermal TR module as a left image sensor, incorrect
        temperatures (e.g. 2000°C) were sometimes displayed as a temperature
        reading after a camera restart.
- Visage Technologies Face Recognition App
 This app could cause permanent false triggers under certain conditions
        and lighting conditions.
- A.I.Tech App Dashboard
 This app could only make half of the camera live image visible in the
        app dashboard
Known Limitations
    
      - Dialog Integration Protocols
 For M73 cameras with only one sensor module, the Admin ->
          Camera Administration -> Integration Protocols dialog is
        empty after activating one of the protocols ONVIF
        or Genetec via the
        installation wizard of the web browser. This state can be corrected by
        first deactivating the set protocol ONVIF or Genetec
        and then turning it back on.
- RTSP-Streaming
 If only one image sensor module is connected in the M73, the streaming
        mode  Raw cannot be selected at this time.
 
    
    top
     
    Software Release MX-V7.0.5.16 − for M7 Camera Model M73
    Creation Date: 2020-06-30
    Publishing Date: 2020-07-02
    Enhancements and Improvements
    Support for thermal sensor modules
    This version supports the new M73 thermal sensor modules. These are
      available with different lenses (focal lengths), with and without thermal
      radiometry function and in contrast to the Mx6 camera line also in VGA
      resolution. The thermal sensor modules are permanently installed in an M73
      front panel, which is then mounted in the M73 camera. A thermal sensor
      module can be combined with an image sensor module and another function
      module (e.g. an IR light module). The setup and use of thermal (TR) events
      is done exactly as in Mx6 cameras with thermal sensor modules.
    
      Notes
      
        - In order to display the thermal image, it is mandatory to assign the
          sensor to the left or right camera image in the Admin >
            Hardware Configuration > Image Sensor Configuration
          dialog after installing a thermal sensor module.
- In this version, the Value Range of the
          temperature values to be  measured can not be set to Automatic
          in the Setup > Image Control > Thermal Sensor Settings
          dialog. You must choose between Small
            (High sensitivity)  and  Large
            (Low sensitivity). Ex works, the Value Range is set to Small
            (High sensitivity).
 
    
    
    Bugfixes
    
      - Intensity
          IR Light Module 
 The setting of the IR Light
          Power Level in the Admin 
          > Hardware Configuration > Assign Wires dialog was
        ineffective when activating the IR Light module by a day-night switch.
        The module has always been activated with the highest intensity.
 
Known Limitations
    
      - Dialog Integration Protocols
 For M73 cameras with only one sensor module, the Admin ->
          Camera Administration -> Integration Protocols dialog is
        empty after activating one of the protocols ONVIF
        or Genetec via the
        installation wizard of the web browser. This state can be corrected by
        first deactivating the set protocol ONVIF or Genetec
        and then turning it back on.
- RTSP-Streaming
 If only one image sensor module is connected in the M73, the streaming
        mode  Raw cannot be selected at this time.
    top
     
    Software Release MX-V7.0.4.18-r1 − for M7 Camera Model M73
    Creation Date: 2020-05-12
    Publishing Date: 2020-05-13
    
      Notes on Release MX-V7.0.4.18-r1
      This release is different from its predecessor release 7.0.4.18
        only in the bugfix "IR Light Module disabled".
     
    Enhancements and Improvements
    WDR Feature
    The behavior of the Wide Dynamic Range feature that aims at
      improving images with large differences in image illumination has been
      improved substantially compared to the predecessor release. In particular,
      you do not need to define an exposure
      window to improve the results. In addition, this feature has been improved
      if an IR Light module is attached. If the camera activates this module due
      to diminishing illumination, overexposure of objects close to the camera
      is reduced. The WDR function can be activated in the Setup Menu
        > Image Control > Exposure Settings dialog, and three
      modes are available to adapt to the current scene:  Low
      for low, Medium for medium, and
      High  for large brightness
      differences between dark and bright areas in the image.
    
      Note
      After activating this feature for an image sensor, the camera will
        ignore the settings in the Target Brigthness section of
        the Setup Menu > Image Control > Exposure Settings
        dialog for this sensor..
     
    
    ONVIF-T and H.265
    With this software version, the M7 camera models support the ONVIF-T
        standard. This includes in particular the use of 
        H.265  as a video codec and the display of texts into the
      live image using the ONVIF-T function OSD
      (OnScreenDisplay).
    In addition, the H.265 codec can also be used
      independently of the integration of an M7 camera via ONVIF-T for RTSP
        streaming by any RTSP client, such as VLC. H.265 can also be
      used as a video codec when integrating M7 models into the Genetec
        Security Center via the Genetec integration interface.
    USB Interface
    With this
        version, the USB interface of the camera can be used for the following
        functions:
    
      - Storage of video and audio data in MxFFS format on USB
          storage media (USB sticks, SSD drives or hard drives). The camera
          supports the USB 2.0 standard.
- Integration of an MX-232-IO box for the use of its signal
          inputs/outputs and/or its serial interface
- Connecting a USB FTDI
        adapter for standard RS232 connections
Other Improvements
    
      - Improved data rate for MxPEG/M-JPEG codec
 The video codecs MxPEG and M-JPEG have been further optimized, so that
        data rate savings of about 15% are achieved with the same image quality,
        depending on the setting.
- Saving the current live image
 The Save Image function in the live view of the web
        browser has been improved. Now, regardless of the live stream, an image
        with the best possible JPEG quality is saved.
      
        Notes
        
          - The two lines at the bottom of the live image, which contain event
            information, are no longer output in the saved image with this
            function.
- If necessary, the function's behavior can be configured to restore
            the old behavior. For this purpose, the parameter  SAVE_IMAGE_BUTTON=live
            can be added to the camera configuration file in the SECTION
              homepage.  Currently, this value is implicitly set to
            best.
 
    
Bugfixes
    
      - IR Light Module disabled
          (V7.0.4.18-r1)
 In version 7.0.4.18, when switching to the night mode, a possible
        existing IR Light module was no longer activated.
 
- Message events of the
            Facial Recognition App
 When using the Visage Technology Face Recognition app in
          Operation
            Mode  Recognition,
          message events named  VT_Face were triggered even
          if a person, who had not previously been trained in Operation Mode Enrollment , was detected by
          the system. The event had to be restricted to already known people by
          additional filtering of the event content. This is no longer
          necessary, as in Operation Mode Recognition
            events are only triggered when previously learned faces are
          detected.
- Lens configuration
 In the Admin -> Hardware Configuration
        area, the Lens Configuration
        dialog could be opened incorrectly and
        the settings made there were ineffective. The dialog has been removed.
 
Known Limitations
    
      - Dialog Integration Protocols
 For M73 cameras with only one sensor module, the Admin ->
          Camera Administration -> Integration Protocols dialog is
        empty after activating one of the protocols ONVIF
        or Genetec via the
        installation wizard of the web browser. This state can be corrected by
        first deactivating the set protocol ONVIF or Genetec
        and then turning it back on.
- RTSP-Streaming
 If only one image sensor module is connected in the M73, the streaming
        mode  Raw cannot be selected at this time.
    top
     
    Software Release MX-V7.0.1.20 − for M7 Camera Model M73
    Creation Date: 2020-02-13
    Publishing Date: 2020-02-14
    
    
      Important Notes
      
        - First released software for completely newly developed M73
            model
 This is the first released software version for the new M7 camera line
          with quad-core ARM Cortex-A53 processor. The M73 is the first model of
          this new high-performance camera line. In addition to the well-known
          functions of the Mx6 camera line, this supports completely new
          features such as H.264 streaming with 30 frames/second at 4k
          resolution, the use of 3 sensor or function modules, intelligent video
          analysis with flexible AI and  deep  learning-based Apps and
          many more.
- User interface equals 
 The software of the new model series based on this system
          platform is largely identical in terms of operation, functions and
          menu navigation with the software of the previous Mx6 series. This
          applies both to the configuration via the user interface of the web
          browser as well as to the integration into the 
          MxManagementCenter.
- Support for existing configurations
 Existing camera configuration files from corresponding cameras of the
          Mx6 model series can be loaded directly and used further. This is
          important in the event of a camera being replaced or for the
          integration of new cameras into existing systems. The configuration
          for the fundamentally changed area of the Integration
            Protocols, the completely new functional area of the 
          Apps and all new detailed functions, such as the setting of the IR cut
          filter, must be recreated or adjusted.
 
    The following describes the new features, enhancements and enhancements
      compared to the first version 7.0.0.111 delivered with M73 cameras.
    Enhancements and Improvements
    Support for the new IR-Cut Day & Night Sensor Modules and IR Light
      Modules
    IR-Cut Day & Night Sensor Module
         The M73 supports the use of the new IR-Cut Day & Night
      sensor modules. These are color sensor modules with an integrated swivel
      IR blocking filter for day and night operation. This filter is
      automatically switched off at low illumination, which also provides bright
      images at night and using the possibly integrated IR module. This
      automatic mode is activated by factory setting and the Lux value used to
      switch to night mode can be set in the setup > image control
        > general image settings dialog. In the
      same dialog, the filter can also be switched manually if required.
    IR Light Module
       The activation of a possible integrated IR Light module is coupled to
      the activation of the "Night Mode" as follows:
    
      - If an IR-Cut Day & Night sensor module is also used,
          this is done when switching the IR blocking filter off (see above).
- If the IR Light module is used together with a normal day
          and night sensor module, the IR Light module is activated when the
          night sensor module is activated by the automatic day-night switching.  
Apps
    Additional App for face recognition
      In addition to the A.I. Tech Apps AI* the Visage
        Technology Face Recognition App for facial recognition is also
      available with this version. After installation (see the following notes),
      the activation and configuration of this App is done exactly as for the
      other Apps in the Setup > Certified App
        Control > Certified App Settings dialog.
    Apps AI* from A.I. Tech 
      This firmware release also includes updated and improved versions
      of A.I's AI* Apps. Tech (see below)
    
     
    Notes on
        installing and using the AI* (A.I. Tech) and Visage
          Technology Face Recognition Apps
      
        - These Apps are installed by uploading the file
          'MX_preinstalled_apps_7_0120.app' via the Admin > System
            Update > Update System Software dialog in the web
          browser or using the  MxManagementCenter.  You can download
          this file from the Support > Download
            Center > Software Downloads > Certified Apps section
          of the MOBOTIX web site. The AI* Apps already included in
          version 7.0.0.111 are updated. 
- The update to version 7.0.1.20 will delete previously generated
          results of the Apps AI* that may have been generated and
          stored on the camera's internal SD card.
- By installing the above App package
          'MX_preinstalled_apps_7_0120.app', previously executed configurations
          of the Apps AI* are overwritten again with the factory
          settings. The previously performed configurations can be backed up
          before installation and reloaded if necessary.
 
     
    
      Apps and messages from the MxMessagesystem
      Activating an App automatically defines a matching message in the
        MxMessageSystem, which is sent internally (locally) after a detection of
        the App. All App messages that can be used in this way are listed in the
        Message Events section of the Setup > Event
          Control > Event Overview dialog and can be further
        configured from there. Depending on the App, the messages sent when a
        detection event occurs also contain parameters that can be used for
        event processing. For example, the message can be searched with a
        regular expression as a filter for a text (string). In this case, an
        action is executed only if the message sent by the App contains the
        previously defined text as a parameter. The complete message sent by an
        App during detections, including the parameters, can be listed by
        entering the command <IP>/api/json/messages in the web browser,
        after a previously performed detection.
     
    
    Bugfixes
    
      - A.I. Tech App
        - If one of the A.I. Tech Apps was configured with a sensor
            other than the one currently shown in the camera live image, the
            camera could have done a restart.
- With the application of some A.I. Tech apps (e.g. AIParking)
            a camera restart could occur after a few minutes.
- In addition, after activating the A.I. Tech apps, there
            were performance problems with camera operation in the web browser.
- Full screen recording
 When using the full screen recording, there could be image errors
        (stripes in the picture).
Known Limitations
    
      - RTSP-Streaming
 If only one image sensor module is connected in the M73, the streaming
        mode  Raw cannot be selected at this time.
- USB interface not supported
 This version doesn't support the hardware USB interface yet.
     Copyright ©
        1999 – 2023, MOBOTIX AG, Germany, support@mobotix.com