MOBOTIX Release Notes
Important Information
- This version replaces the previously released MX-V9.1.1.10.
- These release notes apply to both the firmware and the app package.
- Update packages can be installed directly on the S1A-D camera.
- After updating the software, please double-check your configuration to ensure proper operation. Old configurations may no longer work under certain circumstances.
Feedback to MOBOTIX about the S1A-D camera
- Please use only the dedicated email address S1AD-Beta@mobotix.com. Note that feedback submitted through other channels will not be forwarded to the development team.
- The provided issue reporting template must be used. Missing essential information may hinder analysis and resolution.
New Features
- Support for the new camera model S1A-D.
- New dialog "Argus" in Admin Menu → Maintenance. The tool provides an overview of MOBOTIX IoT cameras on the local network. It is intended for small installations of up to ~50 cameras. For larger installations, please continue using MxManagementCenter.
- New dialog "Health Check" in Admin Menu → System Information. Previously only available via MxManagementCenter, you can now directly check the current system status on the camera. A simple traffic light system indicates when issues are detected in certain functional areas.
- Reworked "Exposure Settings" dialog. The camera modules on M1 and M2 are displayed in separate sections. For Day/Night modules, the "Night" profile can apply a different set of exposure settings for night use. The custom exposure windows have been redesigned and can now be enabled/disabled individually as tiles. The dialog has moved to the Admin area and is now available under Admin Menu → Hardware Configuration. Admin rights are required; please check your group policies.
- Improved MxActivitySensorONE app with a new model optimized for dual operation. Note: existing configurations are not compatible and the app must be fully reconfigured.
- Updated MxMessage structure of the MxActivitySensorONE app to
MxActivitySensorONE.profile_summary.<YourProfileUUID>.<eventType>.<ClassName>. Note: existing MOBOTIX message event configurations are no longer valid and must be adjusted.
- z. B.
MxActivitySensorONE.profile_summary.loitering_profile.loitering.total → MxActivitySensorONE.profile_summary.0.loitering.Total
- z. B.
MxActivitySensorONE.profile_summary.motion_profile.motionAI.total → MxActivitySensorONE.profile_summary.0.motionAI.Total
- z. B.
MotionAI_Person (MxActivitySensorONE.profile_summary.motion_profile.motionAI.Person) → (MxActivitySensorONE.profile_summary.0.motionAI.Person)
- z. B.
MotionAI_Vehicle (MxActivitySensorONE.profile_summary.motion_profile.motionAI.Vehicle) → (MxActivitySensorONE.profile_summary.0.motionAI.Vehicle)
- New entry "Training Image" on the "Download Support Information" page. This feature allows you to provide a live image from your camera that can be used to further improve and train our AI models. By contributing real-world camera images, you actively help increase detection accuracy and optimize the future performance of MOBOTIX solutions.
- In Admin Menu → Ethernet Interface, IPv6 operation has been extended with the options SLAAC and DHCPv6.
- New UUID introduced in MxActivitySensorONE for better handling of MxMessage Events
- In the "General Image Settings" there is a new option to "Swap Sensors" to change the assignment of M1 and M2
Improvements and Bug Fixes
- Image quality with WDR has been improved.
- MxActivitySensorONE image freeze has been fixed
Restrictions and Known Issues
- The integrated microphone is only functional with the new MOBOTIX ONE sensor cable.
- Buffered archiving may fail at night due to corrupted sequences (likely caused by high data rates from image noise).
- MxActivitySensorONE not 100% stable yet.
- MxActivitySensorONE: New UUID requires reconfiguring the message event after updating to the new FW.
S1A-D Beta Feedback Template
- Camera info (mandatory)
- Issue Type (mandatory)
- [Bug]
- [Improvement]
- [New Feature]
- Category (optional)
- [Image Quality]
- [Recording]
- [ONVIF]
- [Activity Sensor ONE App]
- [WebGUI]
- [VMS]
- [Documentation]
- [Hardware]
- [Misc]
- Error description (mandatory)
- Description (actual behaviour)
- Steps to reproduce
- Expected behaviour
- Attachments
- Live image (mandatory)
- Screenshots or screencaptures (optional)
- Support information (Report, configuration, camera info – mandatory)