Release Notes for MOBOTIX HUB Software
    Document Information
    
      
        
          | Publisher: | MOBOTIX AG | 
        
          | Author: | Jörg Steuerwald | 
        
          | Date: | 2025-05-23 | 
        
          | Document: | MxHUB2025R1_release-notes_en_v1.html | 
        
          | Confidentiality: | public | 
      
    
    
    Contents
    The MOBOTIX HUB is an open video management platform (VMP) for businesses
      of all types and sizes. It enables the integration of security and
      analysis cameras, access control systems, security systems, environmental
      sensors, software and hardware interfaces to industrial plants and many
      more, in a common control and user interface – centrally, clearly and
      user-friendly. MOBOTIX IoT cameras, like many IP cameras from other
      manufacturers, can be integrated into the system via device-specific
      drivers or via the ONVIF standard.
    The flexible, scalable system is available in five different variants:
      from the free L1 version for small installations with up to eight cameras
      to the L5 variant, which enables highly distributed enterprise solutions
      for several thousand devices to be implemented.
    The following document provides information about the system
      requirements, installation, and specific features of each version of
      MOBOTIX HUB.
    Software Releases—Overview
    
    
    
    System Requirements
    MOBOTIX HUB is suitable for installation and operation on Windows systems.
    The computers used must meet certain system requirements for the following
    software and hardware components: 
    
      -  Windows operating system (Pro, Enterprise, or Server Edition)
- Microsoft SQL-Server
- .NET Framework
- CPU
- RAM
- Network card
- Disk space
- Graphics cards and graphics accelerators
- MOBOTIX HUB Advanced Services is required to use push notifications
Depending on the variant used (L1 to L5) of the MOBOTIX HUB, there are
      differences in these requirements. A detailed description of the system
      requirements for the different variants is available on the MOBOTIX
      website below Services > Download Center > Marketing &
      Documentation > User Manuals  > Video Management Systems >
      MOBOTIX HUB in the document MOBOTIX
        HUB System Requirements.
    Additions to the system requirements
    
      - If you install the MOBOTIX HUB with the Single Computer option, NO
        Microsoft SQL Server has to be installeed already on the system. If
        desired, this will be installed by the HUB installer.
- The specified "Microsoft® .NET 4.7.2 Framework" is already installed
        on a current Windows 10 system. This can be verified by using the 
          Version entry of the Windows Registry Key Computer\HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft
          NET Framework\Setup\NDP\v4\Client.  
- The "Microsoft® .NET Core 2.1.21" listed in the system requirements is
        also installed by the HUB installer.
 
    Recommandation
	    For the optimal usage of the MOBOTIX HUB with MOBOTIX cameras we recommend to install always the MOBOTIX HUB Plug-Ins. This provide a better Forensic Seach and support the configuration of the MOBOTIX cameras, beside the other advance dashboards. More infos available under  MOBOTIX PLUG INs
	    
	    
    Supported
          camera models
    The
        following MOBOTIX camera models can be integrated into MOBOTIX HUB via
        device-specific drivers:
      
    
      - MOBOTIX ONE cameras with
          firmware versions 8.x
- MOBOTIX 7 (P7) cameras with
          firmware versions 7.x
- MOBOTIX Mx6 (P6) cameras
          x16/x26 with firmware versions 5.x
- MOBOTIX P3 cameras
          x14/x24/x15/x25, T24M/T25M with firmware versions 4.x
- MOBOTIX P2 Cameras
          x12/x22
- MOBOTIX MOVE Camera
          Models
For MOBOTIX Cameras we recommend to intall the follow Drivers to get the best performance and support
    
      - MOBOTIX HUB Driver - for MOBOTIX IOT Range like P6/P7/ONE and for all MOVE cameras
- MOBOTIX HUB DriverInstaller - for all former MOBOTIX P2 and P3 cameras 
 Only for special cases in the former IOT Models like P2/P3 a Integration via the standard ONVIF Driver is required. For all new Cameras P6/P7/ONE and MOVE the MOBOTIX HUB Driver  is the best choice. A list of all
      supported camera models can be viewed on the MOBOTIX website also in the
      download area of this software.
    
    Important notes on installing on Windows systems
    Meaning
          of each installation file
    
      
        
          | File
 | Purpose | Installation
                  required or optional | 
        
          | MOBOTIX_HUB_VMS_Products_<Hub
                version>_System_Installer.exe | Installation
                of all server and client components | Required | 
        
          | MOBOTIX_HUB_Desk_Client_<Hub
                  version>_Installer_x64.exe | Installing
                the Desk Client application on 64-bit Windows computers on a
                distributed system | Optional | 
        
          | MOBOTIX_HUB_Desk_Client_<Hub
                  version>_Installer.exe | Installing
                the Desk Client application on 32-bit computers on a distributed
                system | Optional | 
        
          | MOBOTIX_HUB_Plug-Ins_<Plugin
                version>_Installer.exe | Installation
                of specific extensions for the Management Client and Desk Client
                on 64-bit Windows systems for certain functions of MOBOTIX
                Mx7/MOVE cameras (including Mx7 Apps, IoT Events) and Vaxtor | Recommended | 
        
          | MOBOTIX_HUB_MobileServer_<Hub
                  version>_Installer_x64.exe | Installing
                a server component to use a HUB Web Client or HUB Mobile Client | Optional | 
        
          | MOBOTIX_HUB_VideoOS_OpenNetworkBridge_<Hub
                  version>_Installer.exe | Installation
                of a special server component for remote access to MOBOTIX HUB
                live streams or recordings by RTSP clients via the ONVIF
                interface | Optional | 
        
          | MOBOTIX_HUB_VMSDriverInstaller<Driver
                version>.exe (available in the Services
                  > Download Center > Software Downloads > MOBOTIX HUB
                section of the MOBOTIX website) | Installation
                of all device-specific drivers for the different camera models
                (MOBOTIX IoT, MOVE and other manufacturers) | Required | 
         
        
          | MOBOTIX_HUB_VMS Driver<Driver
                version>.exe (available in the Services
                  > Download Center > Software Downloads > MOBOTIX HUB
                section of the MOBOTIX website) | Installation
                of all MOBOTIX cameras optimized drivers for the camera models MOBOTIX IOT and MOBOTIX MOVE families | Highly recommended for optimal usage of MOBOTIX cameras | 
      
    
    The most important installation steps
    The current
        values for <Hub version>, <Plugin version>and <Driver
        version> are specified below specifically for the MOBOTIX HUB that is
        to be installed 
      
    The
          most important installation steps
    
    
    The
        following is an overview of the basic procedure and the most important
        installation steps:
    
      - Download
          the required installation files from the MOBOTIX website
- Review
          and ensure the system requirements 
- Run
          the installation file
            'MOBOTIX_HUB_VMS_Products_<Hub version>_System_Installer.exe'
           with installation of the
          'Management Server' on the designated computer
        - The
            license file (*.lic)
            provided by MOBOTIX
              after ordering the desired MOBOTIX HUB variant is required!
- When
            installing as a "Single computer", all
            necessary server and client components are already installed here.
- When
          you install a distributed system using the "Custom"
          option, install the other
          server components on the designated computers. In this case, the first
          installer running generates special files for this purpose during the
          installation process for each server component.
- If
          needed, install "Desk Clients" on other
          Windows computers using the file 'MOBOTIX_HUB_Desk_Client_<Hub
          version>_Installer_x64.exe' or "MOBOTIX_HUB_Desk_Client_ <Hub
            version>_Installer.exe".
- Install
          the device-specific drivers  on
          the Management Server computer using the file
          'MOBOTIX_HUB_VMSDriverInstaller<Driver version>.exe'.
- If
          needed, install a "Mobile Server" using
          the file 'MOBOTIX_HUB_MobileServer_<Hub
            version>_Installer_x64.exe' on any suitable Windows
          computer. 
- If
          required, install an "Open Network Bridge"using the
          'MOBOTIX_HUB_VideoOS_OpenNetworkBridge_<Hub
            version>_Installer.exe' file on the same Windows computer
          on which the MOBOTIX HUB Management Server was installed.
- When installing a
          HUB L1 variant and also when subsequently managing
        (adding/deleting) devices in such an installation, the server must be
        online and have unrestricted Internet access — or at least unrestricted
        access for outbound http/https requests to the MOBOTIX licensing
        servers. 
 When any changes that involve licensing have been saved, the HUB server
        will automatically contact the licensing servers to obtain the necessary
        device licenses. No site-specific or security related information will
        be transmitted during this time. For all other operations, the HUB
        server can be offline.
 
- When
          installing a HUB variant L2 to L5 start the MOBOTIX
          HUB Management Client and perform an “activation” of the license by
          executing the following steps in the Basics > License
            Information section of the tree structure:
        - do an Online
            activation by entering the access data (name and password)
          for the MOBOTIX Partner Portal, or
- do an Offline
          activation by creating a file for the license request
          (*.lrq), transmission of this file to the contact person at MOBOTIX
          Sales and import of the file (*.scl), subsequently received from
          MOBOTIX Sales for activation.
This completes the configuration and allows the system to be set up and
      configured. A detailed description of the above steps can be found on the
      MOBOTIX website under Services > Download Center >
        Marketing and Documentation > User Manuals > Video Management
        Systems > MOBOTIX HUB > Management Client. It is strongly
      recommended to pay close attention to the documentation Before
        you start installation and Install
        a new MOBOTIX HUB system contained therein before starting the
      installation of a new MOBOTIX HUB system!  
    
    
    
    
    
    
    
    
    
        top 
    Version 2025 R1 of MOBOTIX HUB
    Published on: 2025-05-23
    
    
    
 
    
    
      Note: For
        more information about the features described below, see the program's
        online help.
     
    
    
    
    
    
    New in MOBOTIX HUB VMS 2025 R1
    Support for the SCIM protocol 
    The 2025 R1 VMS release supports the SCIM specification, System for Cross-domain Identity Management. This enables automatic synchronization of users with an external identity provider.
	 
As a result, changes to permissions take effect instantly, instead of at the next login. Automatic deletion of deactivated users is also supported. Configuration of SCIM in the VMS is done through the MIP SDK or via PowerShell scripts. Okta is supported in this VMS release.
    
    
    
    
    
    Changes
          and solved issues
    Changes compared to MOBOTIX HUB VMS Products 2024 R2 
    Changes compared to MOBOTIX HUB Management Client 2024 R2 
    
 No chnages!
    Changes compared to MOBOTIX HUB Recording Server 2024 R2 
     No chnages! 
    Changes compared to MOBOTIX HUB Desk Client 2024 R2 
    An option for Greek language has been added to the Desk Client.
	    
Exporting in Media player format– combined file has gotten new options for:
	- adding camera names,
- adding date- and timestamps
- as well as the option to choose between exporting in a single camera view or an Adaptive View format.
Choosing single camera view produces the same result as before this release i.e. a single file, playable in any media player application, that contains video from multiple cameras, one after the other.
Choosing the new option of Adaptive View produces a single file that will display video from exported cameras in a grid layout, with concurrent video displaying simultaneously. This is similar to the Adaptive View in the MOBOTIX HUB export format, but in a portable file-format. All the new options can be man-aged through Desk Client profiles.
Stricter validation of security certificate setup making IDP Server component mandatory. This has been part of
the VMS since MOBOTIX HUB 2021R1. The change removes any risk of the software doing fallback to unsecure connection methods. 
    Changes compared to MOBOTIX HUB Web Client 2024 R2 
    An option for Greek language has been added to the Web Client.  
    
    Changes compared to MOBOTIX HUB Mobile 2024 R2 
    
    An option for Greek language has been added to the Mobile Clients (iOS and Android).
	    
New navigation for Android has been added:
It is user centered. The users will now be able to act quicker, as the new navigation icons are going to be on the bottom of the screen, closer to the thumb. We are also adding user side panel, where they could find their user information.
Show Notification Badge on the Alarms tab in iOS and Android:
It is now possible to see an indication that there have been new alarms on the alarm icon in the alarm tab in
both iOS and Android.
    Changes compared to MOBOTIX HUB Mobile server 2024 R2 
    
    No changes! 
        Changes compared to MOBOTIX HUB Software Manager 2024 R1 
    
     Since 2024 R2the Software Manager was replaced with the new MOBOTIX HUB Update Manager. It is not possible to use the 2024 R1 Software Manager to upgrade any MOBOTIX HUB VMS applications to 2024 R2 or 2025 R1.
    Changes compared to MOBOTIX HUB Incident Manager 2024 R2 
     No changes.
    Changes compared to MOBOTIX HUB Video Wall 2024 R1 
    
     No changes.
    Changes compared to MOBOTIX HUB Access 2024 R2 
    
     No changes.
    Changes compared to MOBOTIX HUB Transact 2024 R2 
    
     No changes.
    Changes compared to MOBOTIX HUB LPR 2024 R2 
    
     No changes.
     Changes compared to MOBOTIX HUB Open Network Bridge 2024 R2 
     No changes.
    
    Product features to be discontinued in this release 
    
    
 The capability to receive camera events to port 25 or port 5432 has been discontinued for product security reasons. 
    
        
    
    
    
    
       
    
    
    
    
    
    
    
    
    
    
        top 
    Version 2024 R2 of MOBOTIX HUB
    Published on: 2025-02-21
    
    
    
    
    
      Note: For
        more information about the features described below, see the program's
        online help.
     
    
    Changes
          and solved issues
    Changes compared to MOBOTIX HUB VMS Products 2024 R1 
    The VMS installer no longer offers to make a system backup from within the installer. A configuration backup should instead be made using the Management Client before running the VMS installer.
    Changes compared to MOBOTIX HUB Management Client 2024 R1 
     Exiting the Management Client now creates an entry in the audit log.
    Changes compared to MOBOTIX HUB Recording Server 2024 R1 
     Adaptive streaming is now supported also for devices connected using MOBOTIX HUB Interconnect. Please note that after upgrading to VMS version 2024 R2, an ‘update hardware’ operation needs to be performed in the Management Client on each interconnected device, for adaptive streaming to work.
The DSA-1024 algorithm for signing video has been replaced by ECDSA with the secp256r1 curve. Due to this change, validation of a signed export takes more time. This can be noticed in the time it takes to make an export with signatures included, as well as in the Desk Client Player where there is an option to verify media signatures.
A Desk Client version 2024 R1 or older cannot make an export with signatures on a VMS version 2024 R2 or later. Similarly, a previous version of the Desk Client Player will not be able to validate signatures on an export made with Desk Client 2024 R2 or later.
    Changes compared to MOBOTIX HUB Desk Client 2024 R1 
    Availability of Pro Map has been extended to be in MOBOTIX HUB L2, L3, L4 and L5. At the same time, a feature set to assist migrating maps to Pro Maps has been added to the client.
Metadata Search has been extended with updated search filters from the ONVIF Profile M specification (version 23.12) allowing searching for more detailed objects, provided cameras are generating compliant metadata.
An option for Vietnamese language has been added to the Desk Client.
    Changes compared to MOBOTIX HUB Web Client 2024 R1 
    An option for Vietnamese language has been added to the Web Client.  
    
    Changes compared to MOBOTIX HUB Mobile 2024 R1 
    
    An option for Vietnamese language has been added to the Mobile Clients
    An option to change the grid layout on Mobile Clients on tablets
If you use the MOBOTIX HUB Mobile client on tablets, you can adjust how the app visually represents the cameras by changing the grid layout for cameras. Depending on whether you're in portrait or landscape mode, you can choose between one, two, or three columns
    Changes compared to MOBOTIX HUB Mobile server 2024 R1 
    
    No changes. 
        Changes compared to MOBOTIX HUB Software Manager 2024 R1 
    
     The 2024 R1 VMS release was the last release of the Software Manager tool. It has been replaced by the new MOBOTIX HUB Update Manager. It is not possible to use the 2024 R1 Software Manager to upgrade any MOBOTIX HUB VMS applications to 2024 R2.
    Changes compared to MOBOTIX HUB Incident Manager 2024 R1 
     No changes.
    Changes compared to MOBOTIX HUB Video Wall 2024 R1 
    
     No changes.
    Changes compared to MOBOTIX HUB Access 2024 R1 
    
     No changes.
    Changes compared to MOBOTIX HUB Transact 2024 R1 
    
     No changes.
    Changes compared to MOBOTIX HUB LPR 2024 R1 
    
     No changes.
     Changes compared to MOBOTIX HUB Open Network Bridge 2023 R2 
     No changes.
    
    Multiple Recording Server Instances 
    
     The 2024 R2 VMS release no longer supports multiple Recording Server instances on the same machine. 
    Management Client installed help 
    
     The Management Client no longer has installed help files but relies on online help from the MOBOTIX web site. If a workstation running the Management Client does not have internet access, the client will present a link to the relevant help topic. It is also possible to download and install local help files separately. 
    
    Using Interconnect to connect cameras from certain terminated products
    
     With the 2024 R2 VMS release, MOBOTIX HUB Interconnect will no longer be compatible with MOBOTIX HUB L5,L4,L3 and L2. 
    
    Support for Microsoft SQL Server 2014
    
     Microsoft SQL Server 2014 is no longer listed as supported on the system requirements page. 
    
    JPEG transcoding in the Desk Client
    
     The 2024 R2 VMS release no longer supports transcoding video streams to JPEG in the Smart Client. 
        
    
    
    
    
       
    
    
    
    
    
    
    
    
    
    top 
    Version 2024 R1 of MOBOTIX HUB
    Published on: 2024-09-20
    
    
    
    
    
      Note: For
        more information about the features described below, see the program's
        online help.
     
    New and improved features
    MOBOTIX HUB Management Client - Advance Service Reminder 
    
    With Advance Service Reminders in the Management Client, you arm your system integrator or administrator to act proactively instead of reactively.
If a Advance Service subscription is about to expire, a pop-up notification will inform the administrator once when logging into the Management Client. 
    MOBOTIX HUB Desk Client - New Combined media player format
    
    The new combined media player format address the previously mentioned challenges by allowing the user to export in a new format: combined media play format.  
This format creates a combined file containing all exported video sequences, one after the other, in a format playable in a normal media player application on most platforms.   
    
	    MOBOTIX HUB Web Client - Auto-hide the timeline in full-screen mode
    
    You can now auto-hide the timeline when you’re in full-screen mode to maximize your display area. The timeline is automatically hidden after five seconds of inactivity.  
    
	    
	    MOBOTIX HUB Mobile Client - for Android and iOS users
    
    On a pro map, you can now see the new alarms associated with the cameras and view the alarms’ details… This feature is only available in certain MOBOTIX HUB VMS products. See the complete feature list, which is available on the product overview page on the MOBOTIX HUB website.  
    
    
    Changes
          and solved issues
    Changes compared to MOBOTIX HUB VMS Products 2023 R3 
    With the 2024 R1 VMS release we support the new AXIS TU9001 Control Board (joystick) through a Plugin from Milestone, the
XProtect input unit plugin for the Axis T8310.
    Changes compared to MOBOTIX HUB Management Client 2023 R3 
     The 2024 R1 VMS release introduces a Advance Service reminder in Management Client. The reminder will pop up
a maximum of two times before Advance Service expires. Once when there are 100 days left and once when there
are 20 days left. The pop up will show up once per machine.
    Changes compared to MOBOTIX HUB Recording Server 2023 R3 
     No changes.
    Changes compared to MOBOTIX HUB Desk Client 2023 R3 
    
    
    
    
    
    
    Changes compared to MOBOTIX HUB Web Client 2023 R3 
    With the 2024 R1 VMS release Web Client now has timeline in Full screen mode. The timeline is set by
default to auto-hide in Full screen, after 5 seconds of inactivity on the screen. This auto-hide function is
controlled by a setting.
Additionally, the full screen experience is now aligned between the Investigations expand single camera and the Views Grid view and both have the new timeline.  
    
    Changes compared to MOBOTIX HUB Mobile 2023 R3 
    
    There is now Alarm Support on Pro Maps in Mobile Clients. When a camera on the Pro Map is
source of a new alarm, there is an indication for the alarm on the map, showing as red circles. When the
camera is selected information about the alarm will show at the bottom of the screen. Users can go to
the alarm details for more information on the alarm.
    Changes compared to MOBOTIX HUB Mobile server 2023 R3 
    
    Mobile Server now audit logs the logout action and reason from Mobile and Web Clients. Audit log entries will show if a user chose to log themselves out of the system, or if the server dropped their connection for some reason (inactivity or other). 
        Changes compared to MOBOTIX HUB Software Manager 2023 R2 
    
     No changes.
    Changes compared to MOBOTIX HUB Incident Manager 2023 R3 
     No changes.
    Changes compared to MOBOTIX HUB Video Wall 2023 R3 
    
     No changes.
    Changes compared to MOBOTIX HUB Access 2023 R3 
    
     No changes.
    Changes compared to MOBOTIX HUB Transact 2023 R3 
    
     No changes.
    Changes compared to MOBOTIX HUB LPR 2023 R3 
    
     No changes.
        
    
    
    
    
    Changes compared to MOBOTIX HUB Open Network Bridge 2023 R2 
     No changes.
    
    
    
    Product features discontinued in this release
    
      Desk Client installation Help
      - The Desk Client no longer has installed help files but relies on online help from the Milestone web site.
If a workstation running the Desk Client does not have internet access, the client will present a link to
the relevant help topic.   
Support for WinForms plugins in Desk Cleint
      -  Desk Client plugins using WinForms will now generate a warning when compiled. Existing plugins with
WinForms technology will continue to work but generate warnings at compilation time. Use of WinForms is connected to problems with the UI scaling properly at high resolutions in use with Windows
scaling options.   
Product features to be discontinued in the future
    
      Software Manager
      - The 2024 R1 VMS release is the last release of the Software Manager tool. It will be replaced by the new
MOBOTIX HUB Update Manager.   
      Multiple Recording Server Instances
      - The 2024 R1 VMS release is the last release including support for installing multiple Recording Server
instances on the same machine. The feature will not be available in the 2024 R2 release onwards. A
community knowledge base article is available outlining how to upgrade an installation using multiple Recording
Server instances.   
      Using Interconnect to connect cameras from certain terminated products.
      - The 2024 R1 VMS release is the last release where it is possible to use Interconnect together with MOBOTIX HUB products that are terminated on June 30, 2024 (HUB L4, HUB L3, HUB L2 and HUB L1). From the 2024 R2 VMS release onwards this will no
longer be possible.   
      Support for Microsoft SQL Server 2014
      - The 2024 R1 VMS release is the last release including support for Microsoft SQL Server 2014. From the
2024 R2 VMS release it will no longer be listed as supported on the system requirements page.   
      JPEG transcoding in the Desk Client
      - The 2024 R1 VMS release is the last release including support for transcoding video streams to JPEG.
From the 2024 R2 VMS release the setting for this feature (image quality) will no longer be available in
setup mode, in the properties pane   
      SMTP camera events
      - The 2024 R1 VMS release is the last release to include support for SMTP camera events. This feature
has been deprecated and disabled by default for some time but from the 2024 R2 VMS release it will no
longer be available.   
    
     
    
    
    
    top 
    Version 2023 R3 of MOBOTIX HUB
    Published on: 2024-01-12
    
    
    
    
    
      Note: For
        more information about the features described below, see the program's
        online help.
     
    New and improved features
    MOBOTIX HUB Event Server 2023 R3
    
    MOBOTIX HUB Event Server 2023 R3  The MOBOTIX HUB API Gateway 2023
      R3 is now a mandatory component (previously optional). The MOBOTIX HUB
      Event Server 2023 R3 may not function correctly if the MOBOTIX HUB API
      Gateway is not installed. 
    MOBOTIX HUB Mobile 2023 R3
    
    Emergency Alert – Now the users can react even quicker to a new emergency
      alarm. They can acknowledge or mark as false positive in just two
      steps.  The emergency alarm definition needs to be set up in the
      Management Client as explained in the manual.  
    
    
    Changes
          and solved issues
    Changes compared to MOBOTIX HUB VMS Products 2023 R2 
    No changes.
    Changes compared to MOBOTIX HUB Management Client 2023 R2 
     No changes.
    Changes compared to MOBOTIX HUB Recording Server 2023 R2 
     No changes.
    Changes compared to MOBOTIX HUB Desk Client 2023 R2 
    
      - The Desk Client now has the abillity to open multiple video tabs to
        enable the operator to do multiple investigations to work on evidence
        from different views and points in time at the same
        time.   
- Map is updated with support for output devices and the use of shape
        files now allows defining a separate outline color for shapes.  
- Optimization has been done to the login proccess when the Desk Client
        signs in to systems configured with MOBOTIX HUB Federated Architecture.
        The experience of this optimization depends on many factors and will
        especially be noticable with a high number of Management Servers. 
      
- You can now restore an export list even if the export job was
        cancelled or completed successfully. Previously, you could only restore
        the list if the job failed. This change allows users to re-export
        cameras easily if they made a mistake, such as forgetting a
        camera.   
- In the last release, we introduced Adaptive View for Export in the
        Desk Client Player. In this release, we have made some small
        improvements: 
        - Onboarding Guide: When a user opens the Desk Client Player, they
          will now get a guide about Adaptive View. Users can start using it,
          dismiss the guide, or choose not to see it again. Their choice will be
          remembered on their Windows device. 
- Camera Limit Warning: Users will receive a warning if they try to
          display more than 100 cameras in Adaptive View. 
- Persistent Camera Settings: The changes users make to camera
          properties, like turning off bounding boxes, will now be saved in
          Adaptive View. 
Changes compared to MOBOTIX HUB Web Client 2023 R2 
    In 2023 R3 we are releasing a few changes to Web Client which enhance its
      usability: 
    
      - Onboarding guide for new features – a step by step optional guide for
        users to turn on or restart  to preview new features and how to use
        them. 
- Ability to search by camera description in the Left pane – as in Desk
        Client, now operators can search for cameras by terms in their
        description in Management Client and not just the camera name. 
- Renewed Timeline in Investigations tab – users can now benefit from
        the new timeline in the Investigations tab so they can use the new time
        selection mode with brackets, auto-loop selected recording, preview
        bookmarks, etc. 
- Time selection mode helper buttons in Bookmarks Dialogue and
        Investigations tab – we have added helper buttons to both places where
        users can interact with the brackets time selection mode. These buttons
        support the user to quickly find or bring the brackets to their current
        location in the timeline.   
Changes compared to MOBOTIX HUB Mobile 2023 R2 
    
    In the alarm detailed screen there is a video preview now, instead of a
      thumbnail.
    Changes compared to MOBOTIX HUB Mobile server 2023 R2 
    
    In this release we have implemented the following changes to the Mobile
      server and its components: 
    
      - Removed commands, related to system login from the Mobile server,
        which are not in use by the Mobile server admin plugin in the Management
        Client to enhance security. 
- Added indication to the top bar in the Mobile server admin plugin UI
        to indicate to administrators when there is an issue with the
        certificate on the server, so administrators have a clear visual
        indication that something is wrong with the server communication. 
Changes compared to MOBOTIX HUB Software Manager 2023 R2 
    
     No changes.
    Changes compared to MOBOTIX HUB Incident Manager 2023 R2 
     No changes.
    Changes compared to MOBOTIX HUB Video Wall 2023 R2 
    
     No changes.
    Changes compared to MOBOTIX HUB Access 2023 R2 
    
     No changes.
    Changes compared to MOBOTIX HUB Transact 2023 R2 
    
     No changes.
    Changes compared to MOBOTIX HUB LPR 2023 R2 
    
    
      - The 2023 R3 LPR Management Client plugin is not backward compatible
        with older versions of the MOBOTIX HUB Event Server. Please ensure that
        the LPR Management Client plugin is upgraded simultaneously as the
        MOBOTIX HUB Event Server.  
- New generic country module for USA. This module can recognize the
        majority of license plates in USA, including from which state the plate
        is from. 
Changes compared to MOBOTIX HUB Open Network Bridge 2023 R2 
    
      - Open network bridge now returns the absolute position of PTZ camera
        dome in the response of a GetStatus command.
- Open network bridge admin plugin in Management Client now gives admins
        the opportunity to disregard privacy masking in clients, when streaming
        live and playback. This setting only applies to liftable privacy masks
        and works for users who have the Lift privacy masking permission enabled
        for their user and role.  
    
    
     
    
top
    Version 2023 R2 of MOBOTIX HUB inclusive the latest Cumulative Patches
      2023 R2
    Published on: 2023-08-31
    
    
      To install the MOBOTIX HUB, please refer to the Sections System
          Requirements and Important
          notes on installing on Windows systems Important Notes for
        Installation on Windows Systems. The following applies to the names of
        the installation files described there:
      
        - <Hub-Version> = '2023_R2'
- <Driver-Version> = '128a'
- <PlugIn-Version> = '2023-07-03'
- Please install after the MOBOTIX HUB 2023 R2 installation,
            the Cumulative Patches 2023 R2 (Release Notes below the
          normal Release Notes) 
 
    
    
    
      Note: For
        more information about the features described below, see the program's
        online help.
     
    New and improved features
    Adaptive Playback
    The MOBOTIX HUB 2023 R2 VMS release introduces support for adaptive
    playback. Like adaptive streaming in live mode, adaptive playback allows
    recording two simultaneous video streams from the same camera, making it
    possible for the Desk Client to retrieve the stream with the resolution that
    best matches the current view size. This reduces overall network load and
    reduces performance requirements on the PC running Desk Client.  
    Video Restrictions
     
    The MOBOTIX HUB 2023 R2 VMS release introduces support for video
    restrictions. With the video restrictions functionality, it is possible to
    limit access to certain video sequences (video, audio and device metadata)
    to only operators that are authorized to view restricted video. A new set of
    user permissions defines who can create, view, edit, and remove video
    restrictions. 
      
    Deploying MOBOTIX HUB VMS products with limited permissions on the SQL
      server
    The installer UI now supports using pre-created databases during
    installation. This allows the MOBOTIX HUB VMS products to be installed with
    limited SQL server permissions towards a managed on-prem database, instead
    of the previously required system administrator privileges. 
    
    Adaptive View for Export
    When viewing exported video in the MOBOTIX HUB-format using the Desk Client
    Player, you now get an alternative way of viewing video, where the camera
    layout will automatically adapt according to the number of cameras playing
    simultaneously to maximize view size.  
    
    
    
    Changes
          and solved issues
    Changes compared to MOBOTIX HUB VMS Products 2023 R1 
    As of 2023 R2 it is no longer possible to download DLNA from the HUB L5
    installer page. DLNA 2023 R1 will be able to work with HUB L5 products 2023
    R1 or older and won't be compatible with 2023 R2 or further versions.
    
    
    Changes compared to MOBOTIX HUB Management Client 2023 R1 
    The Management Client now supports Windows scaling, which is useful when the
    Management Client runs on high-resolution monitors. 
    Changes compared to Recording Server 2023 R1 
    The startup time for Recording Server failover has been improved. Normal
      failover now starts up to 25% faster and hot standby failover starts up to
      35% faster.
    Changes compared to Log Server 2023 R1
    
    The log server now uses the same certificate configuration as other
      services. This can be set during installation or from Server Configurator.
    
    
    Changes compared to MOBOTIX HUB Desk Client 2023 R1
    The MOBOTIX HUB Desk Client Player will now prompt the user to accept or
    decline sending anonymous usage data to measure and improve the performance
    of the application. The users choice will be saved for that Windows-user and
    will be valid for 6 months, after which the user will be prompted
    again.   Updated Export tab allows making Privacy Masks directly
    in the export tab instead of in a modal window.   Warning message
    regarding connecting to systems running without certificates for encryption
    now only shown once per operator per workstation if the operator chooses to
    save the choice made. The Desk Client will visualize status in the top right
    corner if connected to a system that is not running with
    certificates.   Updated timeline control for better visibility and
    navigation. Desk Client Profile settings allows for the timeline control to
    auto hide when shown in Monitor Wall views or normal views. 
    
    
    Changes compared to MOBOTIX HUB Web Client 2023 R1 
     Web Client displays an error message when a user attempts to download a
      pre-prepared Investigations download package, if that user doesn't have
      the permissions for export for one or more cameras in the Investigation.
      No download link is generated, and the user can't get to the prepare
      packages UI. 
    The Bookmark preview popup is introduced to allow users to preview and
      interact with Bookmarks from within the Timeline and the Views tab,
      without having to navigate to the Bookmarks tab. When opened, the Bookmark
      preview popup immediately starts playing the bookmark footage and will
      automatically loop it back from the start if it remains open.  The
      Add a detailed/ Edit bookmark dialogue is now redesigned with the new
      Timeline included. The new dialogue allows for timeline zoom to be
      adjusted by using the keyboard control and mouse wheel commands, as it
      works in Desk Client. Additionally, the brackets for selecting Bookmark
      Start, End and Bookmark event times have been redesigned and playback
      between the brackets automatically loops back to provide the user with
      confirmation that the selected clip between the brackets is the correct
      one.   A new date and time picker has been introduced to the Web
      Client timeline. It can be accessed in Playback expanded or collapsed mode
      and in Live – only in collapsed timeline mode. The redesigned date and
      time picker will for now only be accessible from the new Timeline in Views
      tab and provides a better user experience regardless of whether users
      prefer manually typing the date they would like to navigate to on the
      Timeline, or if they prefer to use the calendar controls.
    
    
    
    
    Changes compared to MOBOTIX HUB Mobile  2023 R1
    For Android and iOS users   
    Share live video:   
    
      - Users can now collaborate easily and faster with their co-workers,
        they can now share live video from any camera in their VMS using the
        MOBOTIX HUB Mobile app.   
Location on Pro Map:
    To easily find and view video from the cameras closest to the user, they
      can now see their current location on the Map.   
    Grid view with all cameras visible on Map:   
    
      - Users can now watch live video in a grid view with all cameras in the
        area that is visible on the Pro Map.  
    
    Changes compared to MOBOTIX HUB Mobile Server 2023 R1
    
    Mobile server now checks if Management server has encryption enabled before
    enabling the Share service feature flag for Mobile Clients. If no encryption
    is detected Share service is unavailable and Mobile Clients will not display
    share options in their UI. Audit logging is enhanced for create, update,
    export and delete Investigations and Mobile server returns an error when
    unauthorized user attempts to download a prepared export
    package.      
    Updated MultiStream change command with the option to request previous or
    next frame per single camera provided to the command.  
    Changes compared to MOBOTIX HUB Software Manager 2023 R1
     No changes.
    
    
     
    Version
      2023 R2 cumulative patch for MOBOTIX HUB 2023 R2
    Please install the Cumulative Patch after the normal installation of the
      MOBOTIX HUB 2023 R2. This cumulative Patches are ONLY for this
        2023 R2 Version. 
     
    Log
      Server 2023 R2
    
    
      - Fixed an issue that
        prevented very long messages from being saved in the database
 
    Management
      Client 2023 R2
    
    
    
    
      - Fixed an issue where the existing password was being deleted when a
        new character was typed in the password field in Edit Hardware.
- Resolved crash on selecting Hardware Properties tab.
- Fixed not correct number of displayed interconnected devices in client
        license info.
 
    Mobil
      Server 2023 R1
    
      - Resolved crash on selecting Hardware Properties tab
 
    Recording
      Server 2023 R1
    
      - Fixed an issue when decoding H265 encoded streams
- Resolved crash on selecting Hardware Properties tab
 
    Desk
      Client 2023 R2
    
      - Fixed an issue where the ViewItemIndex property of the
        ImageViewerAddOn class was returning incorrect values when navigating
        between workspaces
- Fixed an issue that prevented the inclusion of all plugins during an
        export
- Fixed an issue where name in Export list does not match video when
        camera is dragged over a view outside of setup
- Fixed Map camera field of view not visible
- Increased timeline zoom down to 1 min
- Fixed alarm audio notification issues
- Fixed Start view- Last View option when used for Monitor Wall view
- Resolved crash on selecting Hardware Properties tab
 Attention: Please
        select only the versions of the patch files that match your MOBOTIX HUB
        version!
     
    
      
        
          | File | Purpose 
 | Installation required  or
              optional | 
        
          | MOBOTIX HUB2023 R2 | 
 | 
 | 
        
          | HUB Log Server 2023 R2 Installer
            x64.exMobotix.Hotfix.202307241103.ES.23.1.36.1.822.exe | Update Log Server 2023 R2 | Required | 
        
          | Mobotix.Hotfix.202308171211.MC.23.2.25.160.exe | Update Management Client 2023 R2 | Required | 
        
          | Mobotix.Hotfix.202308171231.MoS.23.2.21.1.63.exe | Update Mobile Server 2023 R2 | Required | 
        
          | Mobotix.Hotfix.2023008171211.RS.23.2.25.1.61.exe | Update Recording Server 2023 R2 | Required | 
        
          | Mobotix.Hotfix.202308171228.DC.23.21.19.62.exe | Update Desk Client 2023 R2 | Required | 
        
          | 
 | 
 | 
 | 
        
          | 
 | 
 | 
 | 
      
    
    
    
    
    
    
    
    
    
    
       top
    Version 2023 R1 of MOBOTIX HUB
    Published on: 2023-04-26
    
    
      To install the MOBOTIX HUB, please refer to the Sections System
          Requirements and Important
          notes on installing on Windows systems Important Notes for
        Installation on Windows Systems. The following applies to the names of
        the installation files described there:
      
        - <Hub-Version> = '2023_R1'
- <Driver-Version> = '127a'
- <PlugIn-Version> = '2023-03-29'
 
    
    
    
      Note: For
        more information about the features described below, see the program's
        online help.
     
    New and improved features
    Installation
          experience
    
      - Backup the SQL Database(s) before MOBOTIX HUB
        upgrades: Ability to create system-wide configuration backup from the
        installer before upgrading your system to 2023 R1. 
- System diagnosis: As of 2023 R1, the MOBOTIX
        Diagnostics Tool provides the ability to run a system prerequisite check
        before upgrading your current installation to any currently supported
        version of MOBOTIX HUB.
Deploying
          MOBOTIX HUB
        VMS
        products
        with
          limited permissions on
        the
        SQL
          server
     
    It is now possible to use pre-created databases during
        installation. This allows the MOBOTIX HUB VMS products to be
      installed with limited SQL permissions towards a managed on-prem database,
      instead of the previously required system administrator privileges. This
      option is currently available using the command line installer. A
      knowledge base article on the MOBOTIX website outlines this deployment
      method.
    In addition, the process for changing the SQL connection strings has been
      streamlined for the four databases that VMS services use. They now exist
      as separate Windows registry keys that can be changed independently. This
      is typically needed if one or more databases are moved to a different SQL
      server. The Administrator Manual describes this process.
      
     
    New
          Share service available to install alongside Management server
    As of 2023 R1, we are releasing a first look at the Share service component.
    The Share service will be available to install as part of the Management
    server installer bundle and requires API GW also be installed, so the Mobile
    clients and server can consume it to generate and access links to bookmarks
    shared between operators. The new service requires encrypted connections to
    the Management server as it is only accessible via HTTPS.
    
    Receive
          events from MOBOTIX HUB through webhooks
    In MOBOTIX HUB 2023 R1 or later, rules in Management Client support the
    webhooks action. Create a webhook item in Management Client with the URL
    from any 3rd party service. Then, set up a rule to trigger it when an event
    happens in MOBOTIX HIUB. With webhooks, administrators are able to integrate
    with code-less platforms such as Zapier or IFTTT. It is simpler than ever to
    transform events happening in MOBOTIX HUB to SMS messages, calls, new
    tickets, Team messages, or even blinking lights. Administrators can use
    webhooks to send new events from MOBOTIX HUB to their own web server running
    on premises or on the cloud. For instance, a Next.js API running on Vercel,
    a Flask API or an AWS Lambda function.
    
    
    
    Changes
          and solved issues
    Changes
          to the installation process
        compared
          to
          MOBOTIX HUB
          VMS Products 2022 R3
    The MOBOTIX HUB Management Server 2023 R1 is not able to communicate with
    Recording Servers versions 2019 R1 or older. If an installation has
    Recording Servers version 2019 R1 or older, then both Recording Servers and
    Management Server need to be updated to 2023 R1 to be operational. Once the
    Management Server is upgraded to 2023 R1, Recording Servers that are version
    2019 R1 (or older) will be operating in offline mode until they are
    upgraded. It is possible to upgrade via an intermediate version to entirely
    avoid Recording Servers going offline. As of 2023 R1, the installation speed
    of the Management Client component is up to three times faster.
    
    
    Changes compared to MOBOTIX HUB Management Client 2022 R3
    No changes.
    Changes compared to MOBOTIX HUB Recording Server 2022 R3
    No changes.
    Changes compared to MOBOTIX HUB Desk Client 2022 R3
    
      - New way of working with live and recorded material.
        The video is now presented on a video tab that can play both live and
        recorded.
        - The operator now can change between live and playback on a
            toggle in the main timeline
- Buttons for Export, Evidence Lock
          and Retrieve Edge Recordings have been relocated to
          the work space toolbar.
- Updated user interface in the Export tab: the tab
        itself and underlying dialogs have been updated to enhance the user
        experience and ease of use.
- Better time synchronization of bounding boxes on top
        of video to position them more accurately on top of the object they are
        highlighting.
- Connection status now indicated with a green or red
        indicator in the top right corner.
Changes compared to MOBOTIX HUB Mobile Clients 2022 R3
    
      - All features include analytics that help us improve
        the product. They are active only when the user allows tracking.
- Share Bookmarks: the users who have credentials and
        permissions to view recordings and bookmarks from certain cameras will
        be able to share links to bookmarks between each other
- Pro Maps: the users will be able to see the cameras
        that are placed via coordinates in the mobile clients as well
- Background Picture in Picture (for Android users only):
        the users will be able to multitask; browse between apps, while they are
        viewing LIVE of a single camera is a smaller window on their screen
- Native Screenshots for Android: now the users can
        take a screenshot with Android as well. In IOS the function already
        exists
- Extended use of biometrics or device credentials: to
        further improve the app security, you can use biometrics or your device
        credentials before you edit or delete a mobile server.
Changes compared to MOBOTIX HUB Web Client 2022 R3
    
      - Live tab now becomes Views tab,
        and there is a new timeline for switching between live and
          playback modes in the Views tab.
- Play backward and forward in
        Playback mode on multiple and single camera views
- Go to previous and next recording controls in
        Playback on multiple and single camera views
- Control playback speed and timeline ruler zoom
        level in Playback mode on multiple and single camera views
- Shuttle control for temporarily updating the playback
        speed backward or forward in playback mode on multiple and single camera
        views
- Bookmarks and recorded sequences visible
        in playback mode - single click on bookmark on the timeline takes user
        to that bookmark open in the Bookmarks tab
- Timeline in Live collapsed by default.
- All Cameras View no longer available in Web Client to
        prevent performance issues with timeline and larger installations
Changes compared to MOBOTIX HUB Mobile Server 2022 R3
    
      - All cameras view option in Mobile server node
        renamed to clarify All cameras view is now only available in Mobile
        clients
- Mobile server down now visible in System monitor
- GDPR compliance: audit log enhancements for
        Investigations created, edited/ saved, download package prepared and
        download started
- Pro maps enablement for Mobile clients
- Operator collaboration via Share service to enable
        sharing of links to preview bookmarks between Mobile client users.
Changes compared to MOBOTIX HUB Software Manager 2022 R3
     No changes.
    
       
    
   top
    Version 2022 R3 of MOBOTIX HUB
    Published on: 2022-12-08
    
    
      To install the MOBOTIX HUB, please refer to the Sections System
          Requirements and Important
          notes on installing on Windows systems Important Notes for
        Installation on Windows Systems. The following applies to the names of
        the installation files described there:
      
        - <Hub-Version> = '2022_R3'
- <Driver-Version> = '122a'
- <PlugIn-Version> = '2022-12-01'
 
    
    
    
      Note: For
        more information about the features described below, see the program's
        online help.
     
    New and improved features
    MOBOTIX HUB Plug In "Search Filter" now available from L2 version
      onwards
    It is now possible to use the full range of search filters of the MOBOTIX
      HUB System (incl. the MOBOTIX HUB Plug-Ins (search filter) in the Desk
      Client search.
    
    General improvements:
    MOBOTIX HUB Management Client device search filter
    It is now possible to search for devices in the recording server tree.
      Searches can be made on device name and IP address. In addition, all
      disabled devices are by default not shown in the device tree, but they can
      be displayed by ticking the checkbox in the search bar.
    New in MOBOTIX HUB Desk Client 2022 R3
     
    Updated visual elements and changes – to structure and
      workflows of some dialogs. The menu in the upper left corner has been
      restructured and the Login Information, Server Jobs and Evidence Lock are
      now separate dialogs.
    The MOBOTIX HUB Desk Client now transmits telemetric data
      to MOBOTIX VMS with the purpose of optimizing the product. Data collected
      includes data on feature usage, errors / exceptions, and system
      configuration. All data is sent encrypted and pseudonymized. Telemetry can
      be turned off from the Management Client.
      
    Changed behavior of Independent playback in the Desk Client has
        been modified – to make it more usable, when using independent
      playback to quickly check up on something witnessed in a particular video
      feed. Now when entering Independent Playback from Live mode, the video
      will skip back 10 seconds and automatically start playing. If Independent
      playback is entered from playback mode, while the video is playing forward
      the video will similarly skip back 10 seconds, while if the video is
      playing backwards the video will skip forward 10 seconds. If the video is
      stopped Independent playback mode will be entered, but no skip will take
      place.
      
    Extended support for ONVIF Profile-M metadata in Vehicle and
        People categories. Also, People, Vehicle and Location are now
      available in more products.
      
    Changes to availability of search agents in Centralized Search.
      Now all built-in search agents are available in all versions of MOBOTIX
      HUB with the exception of MOBOTIX HUB L1.
     It is now possible to configure Home position for PTZ cameras.
    New in MOBOTIX HUB Web Client 2022 R3
    Left pane views/ devices navigation and search – to
      bring the Web Client look and feel closer to the Desk client, we have
      renewed the Live page navigation in the Web Client to have the left pane
      with all views, all camera view and all cameras tree below. The left pane
      can be expanded and collapsed and there is also the ability to search in
      both the views and the devices trees. Once the user has selected what he
      or she were searching for, up to 7 such search items can be kept in the
      recent search suggestions, so that the user can more easily find
      frequently used views/camera feeds.
      
      
    Third-party IDP login – Users can now log into their Web
      Client with their preferred identity provider service. This option is
      however only available for secure, encrypted connections. If the Mobile
      server does not have an encryption certificate setup, the button for third
      party IDP will not appear on the Web Client login page.
      
      
    Toast notifications for alarms raised – when an alarm or
      other event is raised, now the user is prompted to go to the alarms page
      with a toast notification within the Web Client. Similar events are
      grouped in the same toast message, to preserve screen real estate.
      Clicking on the toast message will bring the user to the Alarms tab in the
      Web Client, so they can see the alarm details and respond to it.
    New in MOBOTIX HUB Mobile Client 2022 R3
    For Android and iOS users
    
       Log in with an external IDP – you can log in to the
        MOBOTIX HUB Mobile app using an external IDP. The alternative login
        method allows you to bypass the required user credentials of a basic
        user or a Windows user and continue to be authorized to access the app.
        
      Using biometrics or device credentials to secure the app
        – you can now use biometrics or your device credentials to verify your
        identity before you open the app. Quick authentication based on your
        fingerprint, face ID, or device credentials facilitates access to the
        MOBOTIX HUB Mobile client and improves the security of the app.
        
      Mobile device management (MDM) – MOBOTIX HUB Mobile
        client now supports mobile device management (MDM). With MDM, you can
        manage and secure devices, apps, and data from a unified console.
        
      New user experience – the login procedure splits into
        two. The server screen is now separated from the user log in screen.
        Users can add servers separately and then choose to enter their
        credentials. The new screens are user – centered and the following
        buttons and settings:
      
        - Log out
            
- 
          Change password 
- 
          Disconnect from server 
- Go to the app settings
For Android users
    Playback Timeline (“Time picker”) – the time
      picker has a new and simplified interface. For more information, see Using
      the playback timeline
    New in MOBOTIX Mobile server 2022 R3
    Removed requirement for firewall exception to allow ICMP ping to
        Management server from Mobile server installer. Now the Mobile
      server can be installed without requiring admins/ integrators to add this
      exception to the Management server firewall settings.
      
      
    Added GDPR warning dialogue for enabling push notifications
      – the dialogue will appear when an admin enables Push notifications for
      Mobile clients to notify the user that enabling push notifications might
      make their installation non-GDPR compliant.
      Browsers are now filtered out from the Notifications tab in the Mobile
      server node in Management client so that administrators will only see
      devices that are registered for notifications (In app and Push) and not be
      confused by the browser instances, as Web Client will only receive in-app
      notifications.
    Windows support 
    
    Windows Server 2012 and Windows Server 2012 R2 are no longer
        supported Windows versions.
    Changes compared to MOBOTIX HUB Management Client 2022 R1
    The Remote Desktop shortcut for Interconnected devices has been
    removed.Changes compared to MOBOTIX HUB Recording Server 2022 R2
    Changes compared to MOBOTIX HUB Recording Server 2022 R2
    It is now possible to delete a storage volume that is offline.
    Changes compared to MOBOTIX HUB Desk Client 2022 R2
    A previous limitation in the length of pathnames usable for exporting
      video evidence has been removed
      from the Desk Clients export feature.
    Changes compared to MOBOTIX HUB Mobile Clients 2022 R2
     No changes.
    Changes compared to MOBOTIX HUB Web Client 2022 R2
     No changes.
    Changes compared to MOBOTIX HUB Mobile Server 2022 R2
    No longer requiring user admins to add exceptions to Management server
      Firewall rules to allow ICMP ping during Mobile server installation.
    Changes compared to MOBOTIX HUB Software Manager 2022 R2
     No changes.
     
    
     
    top
    Version 2022 R2 of MOBOTIX HUB
    Published on: 2022-07-29
    
    
      To install the MOBOTIX HUB, please refer to the Sections System
          Requirements and Important
          notes on installing on Windows systems Important Notes for
        Installation on Windows Systems. The following applies to the names of
        the installation files described there:
      
        - <Hub-Version> = '2022_R2'
- <Driver-Version> = '122a'
- <PlugIn-Version> = '2022-07-29'
 
    
    
    
      Note: For
        more information about the features described below, see the program's
        online help.
     
    New and improved features
    MOBOTIX HUB Incident Manager 
     The new MOBOTIX add-on product MOBOTIX Hub Incident Manager is included
      in MOBOTIX HUB L5. See
the
          specific release notes for MOBOTIX HUB add-on products for more
          details. 
    Improved bookmark search
    A new option has been added to filter bookmark search for either headline
      or description text. This enables fewer and more accurate search results.
      The default to search both.
    General improvements:
    Duplicated hardware in the database may block an upgrade
     
     It is possible, but rare, that hardware devices become duplicated in the
      database due to an error state in previous releases. If such duplicated
      hardware is detected during an upgrade, then the installer will first
      attempt to remove duplicates that are deemed safe to remove. If this is
      not possible for all duplicates, then the upgrade will be terminated, and
      MOBOTIX technical support needs to be contacted to manually remove
      duplicates. 
    Windows support 
    
     Windows Server 2022 is now supported. Support for Windows 8.1 has been
      removed. 
    Changes compared to MOBOTIX HUB Management Client 2022 R1
    The Matrix Monitor option under the Matrix node is deprecated and has
      been removed. When deleting an external IDP, the Management Client will
      now also automatically delete all users and registered claims associated
      with that external IDP.
    Changes compared to MOBOTIX HUB Recording Server 2022 R1
    No changes
    Changes compared to MOBOTIX HUB Desk Client 2022 R1
     MOBOTIX HUB Desk Client is no longer released in a 32-bit version.
    Changes compared to MOBOTIX HUB Mobile Clients 2022 R1
     In order to be compliant with GDPR regulations, the push notification
      settings are now disabled by default. This means that users must opt in to
      receiving notifications.
    Changes compared to MOBOTIX HUB Web Client 2022 R1
     Audio is renewed and there is persistence when the user enables the
      speaker on a camera. When they switch between single camera or view and
      grid view, the audio will be reactivated.
     As part of the web client renewal the top pane is redesigned, and the
      navigation is moved to the left. 
     
    
    
     
    
     top
    Version 2022 R1 of MOBOTIX HUB
    Published on: 2022-05-12
    
      To install the MOBOTIX HUB, please refer to the Sections System
          Requirements and Important
          notes on installing on Windows systems Important Notes for
        Installation on Windows Systems. The following applies to the names of
        the installation files described there:
      
        - <Hub-Version> = '2022_R1'
- <Driver-Version> = '121a'
- <PlugIn-Version> = '2022-03-09'
 
    
    
      Note: For
        more information about the features described below, see the program's
        online help.
     
    New and improved features
    Support for external identity providers and single sign-on.
    You can now log in to the MOBOTIX HUB VMS using any external identity
    provider (IDP) that supports OAuth 2.0 and OIDC. Logging in using an
    external IDP is an alternative to logging in as an Active Directory user or
    a basic user. By using an external IDP, you can manage users without
    additional configuration in the HUB Management Client. You must use roles to
    configure detailed access permissions. 
    The external IDP can be set up to require multi-factor authentication.
    Logging in through an external IDP is currently supported by HUB Desk Client
    and HUB Management Client. 
    Users who log in through an external IDP are automatically added as basic
    users. Currently, you cannot use this feature with MOBOTIX HUB Federated
    Architecture.
    General improvements:
    Secure communication: Event and LPR servers.
    To keep MOBOTIX HUB a secure product, features have been added to ensure
    that sensitive information is not disclosed. This feature protects personal
    sensitive information from disclosure and protects access to sensitive
    information. 
    The following changes have been made to MOBOTIX HUB.
    
      - New Basic User authentication model on Event Server, LPR (Plugin and
        Server) and Log Server.
- New certificate group for Event Server and LPR
- HTTPS support for Event Server (bound to the new certificate group)
- HTTPS support for LPR plugin (bound to Event Server)
When upgrading existing installations, the LPR plugins (Desk Client and
    Management Client) MUST be upgraded to the latest version before enabling
    encryption on the Event Server and LPR server.Changes compared to MOBOTIX HUB VMS 2021 R2.
    The audit logs for changes to role permissions are more detailed. The logs
    now show both the old and new values when settings are changed. 
    The following changes have been made to the MOBOTIX HUB installers:
    
      - The management server address must be a URL rather than a machine
        name. This gives users the ability to change the communication protocol
        (http vs. https) and non-default ports during installation in a very
        simple and intuitive way.
- When installing individual components, the correct communication
        protocol (https vs. http) must be specified. Single components must be
        specified. For example, if a recording server is installed separately
        from the management server. management server is installed and the
        management server accepts only secure communication, then an https
        address must be specified when installing the recording server
        installation. Using insecure http communication during installation is
        not allowed in this case. This prevents security misconfigurations of
        the VMS.
- It is mandatory to select a certificate during the installation of a
        separate, standalone component if the management server is set up to
        accept only secure communication. For example, if a recording server is
        installed separately from the management server, and the management
        server accepts only secure communications, encryption cannot be disabled
        during the installation of the recording server, and a certificate must
        be provided to encrypt the communications.
- During the upgrade of a standalone component, it is no longer possible
        to change the address of the management server. Change management server
        address to connect the component to another VMS. If you uninstall the
        component Uninstall and reinstall the component, you can specify a
        different management server address and thus connect the component to a
        different VMS connect the component to a different VMS.
- All MOBOTIX HUB VMS standalone components installed on the same
        computer must connect to the same management server. For example, it is
        no longer possible to have a recording server running on Management
        Server "A" on the same computer as an event server running on Management
        Server "B". 
Changes compared to MOBOTIX HUB Management Client 2021 R2
    No changes
    Changes compared to Recording Server 2021 R2
    The export function now has its own tab in MOBOTIX HUB Desk Client.
    Previously, the function was available in the export window. This provides
    the user with a larger workspace. In addition, frequently used functions
    have been made more accessible, while less frequently used functions have
    been grouped in a separate window. Also, the operator gets better feedback
    when adding video clips to the export list. All of this translates into an
    improved workflow with focus on what's when exporting. When MOBOTIX HUB Desk
    Client is running as part of a remote desktop session, the operator is
    notified. This information is important because hardware decoding of video
    in remote desktop sessions is not possible. Desktop sessions is not possible
    and - possibly - the CPU load is higher, which in some cases may result in a
    worse user experience. 
    The MOBOTIX HUB 2022 R1 release will be the last to support 32-bit operating
    systems for the Desk Client, and Windows 8.1 will be removed from the list
    of supported operating systems. In some cases, the audio was unnecessarily
    delayed compared to the video. The issue has been fixed so that audio and
    video are better aligned.
    Changes compared to MOBOTIX HUB Mobile Clients 2021 R2.
    Bookmark search has been extended to search for user-defined time intervals,
    keywords or specific cameras. Users can also edit the start, trigger and end
    time of bookmarks. The videos of the bookmarks can be displayed in the full
    screen. Users can delete bookmarks from the list by swiping. There is a new
    option to turn on the Video Diagnostics overlay on the Settings tab of the
    applications. Users can now see what codec, frame rate, or resolution their
    camera is streaming at They can also check if it is a transcoded stream or a
    direct stream.
    Changes compared to MOBOTIX HUB Web Client 2021 R2
    The bookmark search is now extended to search for predefined or user-defined
    time intervals, keywords or specific cameras.
    New in MOBOTIX HUB Add-on products 2022 R1
    Changes compared to MOBOTIX HUB LPR 2021 R2
    Support for US government license plates added.
    Changes compared to MOBOTIX HUB Open Network Bridge 2021 R2
    There is support for UTF-8, as well as basic multicast and JPEG streaming.
     
     
     
     
     
     
     
     
     
     
     
     
    
     top
    Version 2021 R2 of MOBOTIX HUB
    Published on: 2021-12-14
    
      To install the MOBOTIX HUB, please refer to the Sections System
          Requirements and Important
          notes on installing on Windows systems Important Notes for
        Installation on Windows Systems. The following applies to the names of
        the installation files described there:
      
        - <Hub Version> = '2021_R2'
- <Driver Version> = '118a'
- <PlugIn Version> = '2021-05-21'
 
    
    
      Note: For
        more information about the features described below, see the program's
        online help.
     
    New and improved features
    Bookmark functions in Web Client and mobile Clients
     
    Bookmark functionality has been added to the web client and to the mobile
    clients. Users can now add and edit bookmarks from the Web Client in a way
    similar to the Desk Client. Quick bookmarks can be added in Live and grid.
    Detailed bookmarks can be added in Single camera Playback. The bookmark
    headline, description and start, event and end times can be edited. Users
    can also search for bookmarks via the Bookmarks tab. It is
    possible to filter by "My Bookmarks" and then see the details and play the
    selected bookmark. 
    Improvements in the Management Client
    
      - Audit logs 
 Audit logs created by the Identity Provider in the VMS are now
        accessible in the Management Client under the Audit logs tab
- Improved GDPR support 
 The VMS will now display a warning message when certain retention times
        are set to values longer than the product’s default values. This helps
        the VMS administrator to be aware of potential GDPR issues for data that
        could contain personal information. The retention times in question are
        alarms, video, audio, metadata as well as audit logs.
 The settings for Pro Maps are all set to unavailable for new
        installations, and a warning of potential GDPR issues shown when the
        administrator changes these.
Improvements in the Recording Server
    
      -  Behavioral after uncontrolled shutdown 
Changes have been made in the Recording
      Server and the media database to reduce startup time after an uncontrolled
      shutdown of the service. Previously a directory scan was needed to rebuild
      information about tables in the media database.
    This has been changed by introducing a small
      SQL database containing information about all the tables. Table
      information can be restored from this database in most cases after an
      uncontrolled shutdown. The small SQL database is implemented using SQLite
      and no additional components are needed on the Re-cording Server. The
      SQLite database files are stored in %PROGRAMDATA%\MOBOTIX
        HUB and it is recommended that this folder is excluded from
      anti-virus scanning. 
    
    Changes in the Desk Client
    The following improvements have been implemented in this application: 
    
      - New symbols 
 Left panel and other places now use different icons to make it possible
        to differentiate fixed cameras from PTZ cameras.
- Camera and view lists 
 Camera list and views list in left panel now allows horizontal scroll
        using SHIFT + mouse scroll wheel, to make it quicker to read long camera
        or view names.
- Export
        - Default exports options are now set in Desk Client profiles to use
          MOBOTIX HUB format option by default, as this is the recommendation to
          use. 
- For AVI exports, if enabling this, the default is now set to mkv
          as this results in smaller file sizes.
- For new installations these settings are locked per default in Desk
          Client settings. In order for the Desk Client operator to change
          these, the Administrator must create a new profile or change the
          default Desk Client Profile
- Views 
 The Camera Navigator view item and Desk Client Simple Mode have been
        removed.
Further changes in the Mobile Clients
    Please check the release notes for the mobile clients in the Apple AppStore
    and Google Play Store. 
      
    
    New functions in MOBOTIX HUB add-on products
    XProtect LPR 
    MOBOTIX HUB LPR 2021 R1 introduces these new country modules
    
      - Armenia (AM)
- Iraq (IRQ)
- Kyrgyzstan (KS)
In the current LPR implementation, the performance of an individual LPR
      server is affected by the number of active country modules installed on
      the individual LPR server. For the region of Europe, MOBOTIX' unofficial
      recommendation is to not activate more than five country modules per LPR
      Server to maintain system performance. In other regions, such as the
      Middle East region, this recommendation does not apply. 
      
      In use cases where recognition of vehicles from a wide set of countries is
      required, for example boarder control, it is recommended to use the
      generic modules, such as the EU Generic Module. These
      modules are specialized in recognizing the most common types of license
      plates across the various EU countries. 
      
      To cover countries that are not covered by the EU Generic Module, we have
      now created an Eastern Europe Generic Module which
      covers an additional nine countries:
    
      - Albania
- Kosovo
- Montenegro
- Belarus
- Macedonia
- Russia
- Bosnia-Herzegovina
- Moldova
- Serbia
Resolved issues
    Active Directory
      Synchronization
    Since the MOBOTIX HUB release 2020 R3 it has been identified that
      synchronization between AD and the VMS did not correctly resolve nesting
      of user groups across different domains. In 2021 R2 those issues have been
      fixed and resolving user groups now works across all the domains under
      transitive trust relationship. For all non-transitive trusts the process
      will only resolve members of the trusted domain.
    Known Limitations
     
    The
        following limitations currently apply to version 2021 R2.
    
      - Insert
            MOBOTIX IoT Cameras via device-specific MOBOTIX drivers
        - 4K
            and 4MP resolutions are not supported.
- It
            is better to change exposure and image settings directly on the
            camera.
- "Express Search"
 This search does not reliably find all cameras (for MOBOTIX drivers
          and ONVIF) while searching for address ranges works reliably.
 
    
   top
    Version 2021 R1 of MOBOTIX HUB
    Published on: 2021-08-18
    
      To install the MOBOTIX HUB, please refer to the Sections System
          Requirements and Important
          notes on installing on Windows systems Important Notes for
        Installation on Windows Systems. The following applies to the names of
        the installation files described there:
      
        - <Hub Version> = '2021_R1'
- <Driver Version> = '116a'
- <PlugIn Version> = '2021-05-21'
 
    New and improved features 
    
      Note: For
        more information about the features described below, see the program's
        online help.
     
    Licensing per activated channel
     
    MOBOTIX HUB VMS products 2021 R1 introduce an improvement in the licensing
    model allowing more enabled channels per device than previously. Some
    devices now require one device license per enabled channel. The license
    requirements for a device can be found in the document "List of supported
    devices" on the MOBOTIX web page in the section Support >
      Download Center > Marketing & Documentation > Video Management
      Systems > MOBOTIX HUB. 
    
    When installing 2021 R1, a warning will be shown if the amount of device
    licenses used by the system will be affected by the improvement in
    licensing. In this case, the warning provides a link to a report including
    those devices which will require more than 1 device license. The warning
    also provides an option to cancel the installation. 
    Increased number of supported device channels
     
    The number of supported device channels has increased from 16 channels to
    512 channels for the ONVIF driver, from 64 channels to 512 channels for the
    Universal Drivers, and from 1 channel to unlimited number of channels for
    the MIP Driver Framework. 
    ONVIF driver update
    The current ONVIF (one-channel) driver has been modified to support up to
    512 channels per device. This means that all ONVIF conformant devices can be
    added to the system with the existing ONVIF driver effective of MOBOTIX HUB
    version 2021 R1 and later, regardless of the number of channels. For MOBOTIX
    HUB versions released before 2021 R1, the ONVIF driver will still support
    1-channel devices only. 
    The current ONVIF16 (16-channels) driver has not been changed. It will
    remain in the upcoming Driver Device Packs for backward compatibility but
    will no longer be updated with new functionality. 
    Universal driver update
    A new Universal512 driver is now available, supporting devices with up to
    512 channels. 
    Change in administration and functionality of basic user
      accounts
     
    User management for the concept of basic users has been changed. When a HUB
    system administrator creates a new basic user, a temporary password is set.
    It is recommended that the administrator checks the box "Force
      basic user to change password on next login". The following
    applies to the registration process and the parameters: 
    
      - The user will be redirected to a change password page when he or she
        tries to login the first time. Rules for password complexity can be
        configured by the HUB system administrator.
- If a user forgets his or her password, then the HUB system
        administrator can set a new temporary password, again selecting the "Force
          basic user to change password on next login" checkbox. 
- A user can change his or her password at any time by clicking the Change
          Password link in the client login dialog. This is available
        in all clients. The administrator does not have access to a password set
        by the user.
- A user will be temporarily locked out if the wrong password given more
        than N login attempts.
- The HUB system administrator can lock a user account by changing the Status
        field on the basic user from Active to Locked. The
        administrator can also unlock a user account by setting status to Active.
When logging into a MOBOTIX HUB system, you may see a warning stating
      that the system is not secure. Because this release is about securing the
      communication between system components, the client applications consider
      any system without a certificate non-secure. This also includes any
      previous version, for example if you are using the latest version of
      MOBOTIX HUB Desk Client with a previous version of the MOBOTIX HUB system
    Device firmware update using the Management Client
     
    It is now possible to update device firmware through the Management Client.
    This new feature allows you to update the firmware for a single device only
    or for several devices of the same brand/model together. There is a new
    wizard for bulk firmware update available in the Maintenance menu of the
    Management Client. 
    The new feature makes it easier for the VMS administrators to maintain the
    latest device firmware when a new firmware is available. This feature is
    available in the following system versions and for the following device
    drivers:  
    
      - The single firmware update is available for all MOBOTIX HUB products.
- Bulk firmware update is available only for MOBOTIX HUB  L4 and
        MOBOTIX HUB L5.
- Supported drivers are Axis, Bosch, Hanwha and ONVIF.
 
     
    
      Note: This
        feature also depends on the current firmware version of the device. Some
        old versions do not support a firmware update from MOBOTIX HUB.
     
    
    Pro Map improvements
     
    Pro Map kann jetzt Kartenelemente verschiedener Typen gruppieren. Dies
    ermöglicht einen einfacheren Überblick über Systeme mit vielen Geräten an
    einem Ort. Beim Verkleinern werden Kartenelemente zu Clustern kombiniert,
    und beim Vergrößern werden die Cluster auseinander gerissen, bis bei den
    niedrigsten Zoomstufen Elemente einzeln angezeigt werden. Pro Map kombiniert
    jetzt einzelne Kameras und andere Geräte zu Clustern, um eine einfache und
    unkomplizierte Navigation und Visualisierung beim Verkleinern zu
    gewährleisten. 
    Zusätzlich zur bestehenden Unterstützung für die Anzeige von
      Kamerasymbolen direkt auf der Karte bietet diese Version Unterstützung folgende
        Funktionen:
    
      - Input devices:
 Display input devices such as door sensors and door bells
        directly on Pro Map for an even better overview.
- Audio:
 Reduce time to action and listen to audio directly from the Pro
        Map.
- Alarms:
 React immediately, when the alarms are marked as blinking red
        circles on the Pro Map and acknowledge them with a right-click.
 
Media database repair improvements
    
     
    Improving the stability of the media database is an ongoing process. In this
    release, we have improved the repair time for a corrupted media database. 
    By moving detailed information from low-level index files to higher-level
      files, we have limited the number of files we need to read to repair the
      database, thereby significantly reducing the repair time. The time saved
      depends on the size of the database and the location where the files are
      located, but we saved up to 50% time in our tests.
    The following is an example of a test performed: 
    A media database on a local disk with 100,000 corrupted tables showed the
      following results:
    
      - 2020 R3: 1641 seconds
- 2021 R1: 884 seconds
In this case, we saw a 46% improvement in repair time compared to previous
    versions
    New functions in MOBOTIX HUB add-on products
    XProtect LPR 
    MOBOTIX HUB LPR 2021 R1 contains these new country modules:
    
      - Myanmar
          (BUR) - New country module that recognizes all standard license plate
          types  
- Libya
          (LAR) - New country module that recognizes all standard license plate
          types  
- El
          Salvador (ES) - New country module that recognizes all standard
          license plate types  
Changes and solved issues
    General changes
    
      - Prior to MOBOTIX HUB 2021 R1, when changing the hostname of the
        computer running the Management Server, the Management Server was not
        able to start again. The Management Server and any other components
        running on that machine could be fixed manually or by reinstalling the
        system. Starting from the 2021 R1 product release, all servers running
        on a computer that got a new hostname can be re-configured by doing a
        registration using the Server Configurator. 
- Server Configurator is now backwards compatible. Since there is only
        one Server Configurator installed on a machine, the Server Configurator
        needs to be able to handle all versions of installed components. We do
        not support the case in which an older component is installed on top of
        newer components. Hence, it is ensured that the Server Configurator is
        always the same version or newer than the other components on the
        machine. 
Changes in the MOBOTIX
      HUB Management Client
    
      - System
          monitor now shows the status for failover recording servers. If the
          failover server has issues with SSL due to certificate problems or it
          cannot authorize with the authorization server, that is shown in
          system monitor.
- The generic
          de-warping feature has been expanded with an option to specify the
          appropriate degrees for the device’s horizontal field of view (FOV).
          This enables an improved de-warping experience for a wider range of
          devices. The default FOV has been changed to 180 degrees.
- There is a
          new tab, Remote Recorder, in the Management Client
          for configuring credentials for connections to a remote recorder
          device. Such devices can be used as an edge storage for a group of
          cameras. Currently this option is only implemented for the Axis Video
          Recorder S3008.
- The Menu bar
          has been changed. The Edit menu has been removed and
          a new menu Maintenance has
          been added.   
- An IP version
          filter has been added in Express
            scan result screen in the Add
            Hardware dialog. This makes it possible to distinguish IPv6
          addresses from IPv4 addresses of the same device. By default, only
          IPv4 addresses are shown.
- A
          new time rule is available that can run specifically when in failover,
          or not in failover. This makes it possible to lower the resolution and
          frame rate when running on a failover recording server. The rule is
          not limited to changing these two settings but can be used for general
          changes as most other rules. 
Changes in the MOBOTIX HUB Web Client
    In this application, the functions have been improved:
    
    
      - Encryption
          options have been added to export of investigations results.
- Digital
          signing now happens automatically when exporting video.
- Audio
          permissions are now requested upon microphone usage.
- One time
          export: the Export Investigations link usage has
          been limited to one time download. The export link expires after the
          first download (in previous versions it did not expire).
- Investigation
          retention time added, and investigations are automatically deleted
          after this time expires. 
Driver improvements for
      MOBOTIX IoT cameras
    The IoT cameras are now also found on the network and integrated into the
      system if only the HTTPS protocol, without additional HTTP, is activated
      on them. 
    Known Limitations
     
    The
        following limitations currently apply to version 2021 R1.
    
      - Insert
            MOBOTIX IoT Cameras via device-specific MOBOTIX drivers
        - 4K
            and 4MP resolutions are not supported.
- It
            is better to change exposure and image settings directly on the
            camera.
- "Express Search"
 This search does not reliably find all cameras (for MOBOTIX drivers
          and ONVIF) while searching for address ranges works reliably.
- Setting
            up a Failover Server
 After setting up a failover server, the status of the failover server
          in the Management Client is always displayed incorrectly as a
          "connection error". The failover events are also not currently usable
          in any way
     top
    Version 2020 R3 of MOBOTIX HUB
    Published on: 2021-05-26
    
    
    Specific features for MOBOTIX IoT cameras 
    
      Note: For additional information about the
        features described in the following, please see the application's online
        help. 
     
    Dynamic events 
    After the
        integration of MOBOTIX cameras of the series MOBOTIX 7, Mx6 and P3 via a
        device-specific MOBOTIX driver (selection from Mobotix M/D/V/S series, Mobotix Q*, Mobotix T*), events of these
        cameras from the following event groups can also be defined in the HUB
Management
          Client for these
        cameras as ("dynamic") events:
    
      - Image
          Analysis Events
- MxMessageSystem
          Events
- Meta
          Events
- Environment
          Events
The events
        defined in the MOBOTIX HUB can then be used in Rules and Alarms,
        for example to start recording through the HUB Recording Server. 
         
    In
        the MOBOTIX
          HUB variants L4 and L5, the HUB
          Desk Client Search
        dialog allows to search for recordings of such events by entering
          MOBOTIX IoT Events as a search filter.  
         
    
      Note: This special search function of the Desk Client
        requires a MOBOTIX HUB variant L4 or L5..
     
    
      In order for the events of a MOBOTIX IoT camera to be used as "dynamic
      events" in
        the MOBOTIX HUB, the following preparations are necessary on the
      IoT camera before  inserting it into MOBOTIX HUB:
    
      - Activation
          of the general Arming
- Configuration
          of the desired Event
- Activation
          of the camera-internal Recording as Event Recording
          (e.B. with recording time 2s and recording frame rate 1 fps)
 
    Analytics Events from MOBOTIX 7 Cameras
    After
        integrating a camera from the MOBOTIX 7 model series via a
        device-specific MOBOTIX driver (selection
          Mobotix M/D/V/S series), events of a Vaxtor
          LPR App activated on the camera for the detection of license
        plates, can be defined as Analytics Events
          in the MOBOTIX HUB and can also be used within
          Rules and
        Alarms, e.g. to start
        a recording.
    In
        order for the events of the Vaxtor LPR App to be used in the HUB, the
        following settings must be made in the
          Milestone section of the  Vaxtor
LPR
          Settings dialog to configure the App:
    
      - URL: <IP
          address of the MOBOTIX HUB Management Server>:<Port-Nummer>
- Camera Name:
          <IP address of the camera or camera name as defined in the HUB>
After
        integrating a camera configured in this way, the corresponding Analytics
        Event can then be activated in the HUB Management Client as follows:
    
      - Activation of the
            Analytics Events
          in the dialog Tools ->
            options 
 The same port number must be used as in the camera configuration in
          the URL field
          (see above).
- Add an Analytics Event
          named
          VaxALPR
            On Camera Event in the Rules and Events
          >
            Analytics
            Events section
            in the HUB Management Client's tree structure.
Then,
        this Analytics Event can be used just like any other event within Rules
        and Alarms.
    After installing an extension
          of the HUB Desk Client using the installation file
        'MOBOTIX_HUB_Plug-Ins_2020_R3_Installer.exe', the Search
        dialog of the Desk
          Client then displays an additional search area
        VaxALPR,
         which allows the search for
        a specific licence plate recognized by the app. By displaying this
        search area multiple times, it is also possible to search for several
        licence plates at the same time. 
    
      Note: This special search function of the Desk Client
        requires a MOBOTIX HUB variant L4 or L5..
     
     
    
    Known Limitations
     
    The
        following limitations currently apply to version 2020 R3.
    
      - Insert
            MOBOTIX IoT Cameras via device-specific MOBOTIX drivers
        - On
            the cameras, the HTTP protocol must be active and used for
            integration.
- 4K
            and 4MP resolutions are not supported.
- It
            is better to change exposure and image settings directly on the
            camera.
- "Express Search"
 This search does not reliably find all cameras (for MOBOTIX drivers
          and ONVIF) while searching for address ranges works reliably.
- Setting
            up a Failover Server
 After setting up a failover server, the status of the failover server
          in the Management Client is always displayed incorrectly as a
          "connection error". The failover events are also not currently usable
          in any way.
 
     Copyright ©